Nuclear Magnetic Resonance spectrometer for identification of organic compounds in solutions. The device can analyze pure compounds and multi-component mixtures. The spectrometer can record the magnetic resonance spectra of the 1H, 13C, 15N, 19F, 31P nuclei, and various two-dimensional spectra. The principle of operation is based on different electron shielding of the nuclei. The device has a permanent magnetic field of 9.4 Tesla, a room-uniform shim system for optimum magnetic field uniformity required for 1D, 2D and 3D experiments without sample cell rotation; at least 20 orthogonal gradient controls and 60-position automatic sample changer.
Keywords:
Nuclear magnetic resonance NMR, COSY, DEPT, HMBC, HSQC, NOE
Featured research equipment, ICT technologies, inclusive and creative society, Health technologies, biotechnologies and safe food, New production processes, materials and energy efficiency
9.4 Tesla permanent magnetic field . Room temperature homogeneity outdoor activities ( shim ) system for optimal magnetic field homogeneity needed for 1D , 2D and 3D experiments without rotation of the sample cuvette , and not less than 20 orthogonal gradient control. Not less than 2 equivalent and interchangeable frequency channels of communication with the full wide -frequency generation in each , and the minimum interval for each channel 6-430 MHz Complete digital phase and amplitude of the best generation of long-term stability to achieve Digital real- time compensation The required frequency change: steps < 0.01 Hz Phase change: steps < 0.01 Grad, with no more than 25 ns duration Radio frequency system output signal phase singalong / accuracy by changing the power attenuation ( monotony ): not more than / - 0.5 and 90 dB power conversion range. Individual and / or along the phase , frequency and / or amplitude of the event time : no more than 25 ns Impulse control temporal resolution of 12.5 ns or less Software -controlled variable temperature unit , the temperature change of 0.1 ° C increments . Temperature changes at the interval narrower than the range - 150 to 180 ° . a) 5 mm head with actively shielded Z - gradient, can apply monitoring / irradiation of the NMR core range from 15N to 31P ( below) as well as 1H and 19F . Automatic selection, setting and atitaikymas all clusters interval from 15N to 31P . The ability to record the 1H and 19F spin interactions termination and vice versa . The minimum required parameters : Signal / Noise: 19F sensitivity ≥ 350:1 (TFT sample , the 1H interactions termination ) 31P sensitivity ≥ 150:1 ( TPP sample) 13C sensitivity ≥ 190:1 (ASTM test) 15N sensitivity ≥ 25:1 (90 % formamide sample) 1H sensitivity ≥ 450:1 (0.1 % EC sample , 200 Hz) Temperature changes at the interval narrower than from - 150oC to 150 oC . b ) CP / MAS head 15N - 31P , 1H ; Rotor size 4 mm, rotation frequency up to 15 kHz; shall be accompanied by a pneumatic module for precise spin speed , transfer MAS rotor system . The head must be compatible with automatic sample changer. Temperature changes at the interval narrower than the range of -50 ° C to 80 ° C .
Nuclear magnetic resonance investigation in solutions Two-dimensional corelation spectral studies Analysis of biological samples