Search

Fermentation Kit- BioFlo 110 M1273-1162

Description: Fermentation Kit- BioFlo 110 M1273-1162

Technical specification: total volume 3,0 liters, working volume 0,8-2,2 liters, mixing, 200-240 V

Usage area: Microorganism cultivation

Keywords: fermentation, cultivation

Spiral mixers (DIOSNA SP 24 F

Description: Spiral mixers (DIOSNA SP 24 F

Technical specification: output 24 kg, working volume 45 liters

Usage area: dough mixing

Keywords: dough mixing

Platilab 110 H

Description: Platilab 110 H

Technical specification: temp. range -40C-90C; working volume 110 liters

Usage area: storage of microorganisms

Keywords: freezing, storage

Centrifugal Vacuum Concentrator/Freeze Dryer

Description: Centrifugal Vacuum Concentrator/Freeze Dryer

Technical specification: Low speed vacuum centrifuge: 1800rpm. Heated compartment temperature range: 30 to 60°C. Minimum pressure rating: <15hPa. Temperature minimum -110°C

Usage area: freeze-drying

Keywords: freeze-drying

Solid-Liquid Extractor

Description: Solid-Liquid Extractor

Technical specification: Number of extraction places: 4;valume of basic vessels: 200 ml; recommended working volume: 4x100 ml; Max . temperature: max. 200 °C

Usage area: Extraction

Keywords: extraction

Acoustic spectrophotometer

Description: Acoustic spectrophotometer

Technical specification: worging frequency range 4-80 kHz, measurement time 10 s

Usage area: Porous system structure analysis

Keywords: acoustics

SafTest system

Description: SafTest system

Technical specification: Measures percent fat i all food matrices; 570/690 filter for the ParoxySafe and AciSafe, and 550/690 filter for the AldeSafe and AlkalSAfe

Usage area: SafTest system is tests for determine lipid quality and freshness.

Keywords: Quality of fat

Spectrophotometer

Description: Spectrophotometer

Technical specification: UV range 190-1100 nm

Usage area: absorbance measurement

Keywords: spectrophotometer

Dough forming mashine

Description: Dough forming mashine

Technical specification: uotput 120 goods/h, 1.2 kW

Usage area: dough forming

Keywords: dough forming

One-screw extruder Inbramaq “LABOR PQ-30”

Description: One-screw extruder Inbramaq “LABOR PQ-30”

Technical specification: output 20-25 kg extruded products/h, 220-380 V, 1760 rpm, 60 Hz, 5 temperature zones: I-20C, II- 40C, III-60C, IV-80C, V-100C

Usage area: production of extruded products

Keywords: extruded products

Baking oven MIWE Condo

Description: Baking oven MIWE Condo

Technical specification: 3 baking chambers, output 72-120 baked goods/h, 35 kW

Usage area: baking experiments

Keywords: baking, oven

Thermo - chamber MIWE

Description: Thermo - chamber MIWE

Technical specification: working volume 0.98 m3

Usage area: proofing

Keywords: proofing

Vacuum-packaging machine HEFESUS Atchena SLB

Description: Vacuum-packaging machine HEFESUS Atchena SLB

Technical specification: output 240 packages/h, 1.5 kW

Usage area: packaging

Keywords: packaging

Electrophoresis unit OmniPAGE

Description: Electrophoresis unit OmniPAGE

Technical specification: Proteins separation using SDS-PAGE

Usage area: Proteins analysis

Keywords: Unit dimension 19 x 13 x 15 cm; gel size 7.5 x 8 cm; 2 gels; 8 samples per gel

Particle size analyzer

Description: Particle size analyzer

Technical specification: Static light scattering. Measuring from 0,1 to 2000 micrones.

Usage area: Accurate and rapid particle size measurements

Keywords: Particle size distribution, particle size

Texture analyser TA.XT plus (Stable Micro System, UK) with load cell, platform and basic software

Description: Texture analyser TA.XT plus (Stable Micro System, UK) with load cell, platform and basic software

Technical specification: Capacity - 50 kg, speed range - 0.01 - 40mm/s. Equipped with cutting, bending, extrusion, tension, penetration probes

Usage area: Measurement of textural properties of foods and cosmetics

Keywords: Textural properties

Works with KT1000131M HPLC-MS

Description: Works with KT1000131M HPLC-MS

Technical specification: Works with KT1000131M HPLC-MS

Usage area: Works with KT1000131M HPLC-MS

Keywords: HPLC-MS

High performance liquid chromatograph

Description: High performance liquid chromatograph

Technical specification: chromatographic separation of mixtures Maximum pressure up to 5000 psi, maximum flow rate up to 10 ml/min, UV range 190-500 nm.

Usage area: quantitative analysis of individual compounds in mixtures

Keywords: HPLC

Accelerated solvent extraction

Description: Accelerated solvent extraction

Technical specification: Automated extractor with possibility to use different size extraction cells and three different solvents.

Usage area: Accelerated solvent extraction

Keywords: Accelerated solvent extraction

Fermenters

Description: Fermenters

Technical specification: fermenters with working volume 35-500 ml and 300-1200 ml, infrared radiation is used to warm the culture; does not require cooling water. used to warm the culture;

Usage area: Fermentation and cultivation with bacteria, yeasts or fungi.

Keywords: Laboratory fermenters, microbiological culture, fermentation

Electrophoresis technique SDS-PAGE.

Description: Electrophoresis technique SDS-PAGE.

Technical specification: 160x(140-160-200-220)mm

Usage area: Proteins separation using SDS-PAGE

Keywords: Proteins analysis

Bottle filler

Description: Bottle filler

Technical specification: Semi automatic bottle filler; flexible filling of different 0,3-1 L glass bottles possible

Usage area: Beer filling into the glass bottles

Keywords: Beer filling

Meat and fish products formation equipment

Description: Meat and fish products formation equipment

Technical specification: Vacuum Stuffer“Frey” F-Line F 55. Fully electronic continual vacuum stuffer for STRAIGHTFILLING, PORTIONING and LINKING with swiveling linking gear and Global drive. Filling power up to 2.900 kg/hour. Housing and hopper completely made of stainless steel. Filling hopper divisible 100 liters or 60 liters. Filling pressure up to max. 25/35 bar. Integrated vacuum system and water separator electronically locked step (optionally). Vacuum pump 16 m³/hour. Portioning range 5 - 100.000 g (5 - 999 g in 0,1 g steps). Portioning speed max. 300 portions/min. Clipper MC12/. Works with clips C1212, C1214 Stainless steel. Base dimensions: 25 x 27cm Straight or crossed clip closing. Magazine capacity 250 clips.

Usage area: Meat and fish products formation

Keywords: Meat and fish technology

Supercritical extractor

Description: Supercritical extractor

Technical specification: Pilot scale (10 L) supercritical fluid extraction system with separators and possibility to add entrainer.

Usage area: Supercritical extraction

Keywords: Supercritical extraction

Supercritical extractor

Description: Supercritical extractor

Technical specification: Laboratory (50mL, 500mL) supercritical fluid extraction system with separators and possibility to add entrainer.

Usage area: Supercritical extraction

Keywords: Supercritical extraction

Water activity measurement, CR400 CR-400, Konica Minolta

Description: Water activity measurement, CR400 CR-400, Konica Minolta

Technical specification: aw measurment from 0.05 to 0.95

Usage area: Water activity measurement

Keywords: Water activity

Equipment of Dairy Components Concentration

Description: Equipment of Dairy Components Concentration

Technical specification: Membrane filtration equipment (4 flat sheet membranes; max. inlet pressure: 7 bar; max. operating temperature: 80 °C; pH rage: 1-14; cross-flow: 3-10 l/min); spray dryer (inlet air temp.: 40-230 °C; drying air throughput: from 100 to 300 m3/HR; peristaltic pump with flow rate up to 32 ml/min); sublimator (9 drying programs with steps (temperature, pressure and time); volume: 95 l; capacity: 5 kg/24 h; shelf temp.: till 80 °C)

Usage area: Membrane filtration equipment is used for dairy and whey ultra-and micro-filtration; Spray dryer - for drying of dairy products by hot spraying method; sublimator - for drying of dairy and other foods by sublimation (in cold and vaccum) method.

Keywords: Microfiltration; Ultrafiltration; Drying; Freeze-drying; Sublimation

Equipment of Dairy Thermal Treatment in Ultra High Temperature

Description: Equipment of Dairy Thermal Treatment in Ultra High Temperature

Technical specification: Small-scale pasteurization and sterilization flow system (thermal treatment temperature: till 150°C; holding time: from 2 s till 2 min; average capacity: 10l/h; pressure: 1-5 bar; weight volume hopper: 5 l; tubular and plate heat exchangers)

Usage area: Thermal treatment of raw milk (pasterization, sterilization and ultra hight thermal treatment (UHT))

Keywords: Milk pasterization, Sterilization; UHT

Technological Equipment of Cheese Small-scale Production

Description: Technological Equipment of Cheese Small-scale Production

Technical specification: Cheese vessel (capacity: 50 l; temperature rage: 4-90 °C; with cheese harp); cheese press (max. capacity: 50 kg; pressure: up to 10 bar; pneumatic); climatic chamber (temperature and relative humidity control); automated multipurpose and pressure vessel (internal volume: 20 l; temperature inside the container: up to 140 ° C, pressure: till 3 bar, automatic temperature and pressure control, three types of mixers)

Usage area: The production of various types of cheese, their formation, removal of whey; cheese ripening in the regulated environment.

Keywords: Curd cheese; Fermented cheese, Melted cheese; Cheese ripening

Gas analyser OPTIMA7 BIOGAS

Description: Gas analyser OPTIMA7 BIOGAS

Technical specification: Operatiing temperature 5-45 °C, max. 95 % RH, measurement range: 0-21 vol. % O2, 0-100 vol. % CH4, 0-60 vol. % CO2

Usage area: O2, CH4, CO2 measurements in gas

Keywords: O2, CH4, CO2, gas

Potentiostat mAUTOLAB

Description: Potentiostat mAUTOLAB

Technical specification: Potential range /- 5 V, Current ranges 10 mA to 10 nA

Usage area: Electrochemical investigations of organic materials, evaluation of energy levels of organic molecules

Keywords: oxidation-reduction potential, jonizacjos potencialas, elektroninio giminingumo energija

Comprehensive LECO GC´GC-TOFMS 4D system

Description: Comprehensive LECO GC´GC-TOFMS 4D system

Technical specification: Comprehensive GC´GC system with time-of-flight TOFMS detector

Usage area: Determination and identification of volatiles in the liquid samples and in the headspace of samples (vapour phase)

Keywords: GC´GC system

UV Vis spectrometer Lambda 35

Description: UV Vis spectrometer Lambda 35

Technical specification: UV-Vis spedtrum registration 200-1000 nm

Usage area: Electronical spectrum of solutions registration 200-1000 nm

Keywords: UV-Vis

Hybrid mass spectrometer

Description:

Hybrid mass spectrometer

Technical specification:

Separation of compounds and recording of UV spectra in the range of 200-500 nm, and MS spectra in the range of 20-8000 m/z with the accuracy of less than 1 ppm.

Usage area: Chromatographic separation of compounds and quantitative or qualitative analysis of individual compounds

Keywords: UPLC-MS

Distiller Buchi Glass Oven B-585

Description: Distiller Buchi Glass Oven B-585

Technical specification: Temperature range 40-300oC; drying volume upto 250 ml; Kugelroh distillation volume from 5 to 40 ml

Usage area: Equipment for distillation, sublimation, freeze-drying or drying of organic materials in vacuum

Keywords: sublimation, drying, distillation, vacuum

Set of equipment for sublimation

Description: Set of equipment for sublimation

Technical specification: Possible ammounts for sublimation is up to 100 g; achievable vacuum up to 10-3 mbar, condenser could cooled by water

Usage area: Sublimation of the organic materials

Keywords: sublimation

Biodegradability measuring complex

Description: Biodegradability measuring complex

Technical specification: Measuring range (oxygen concentration) from 0 to 4.0 mg / l.

Usage area: Measuring of biochemical oxygen demand

Keywords: Biochemical oxygen demand, biodegradability

Optical tensiometer (contact angle meter)

Description: Optical tensiometer (contact angle meter)

Technical specification: Measuring range 0-180o, 0.01-1000mN/m

Usage area: Optical tensiometer allow direct measurements of surface tension, interfacial tension, contact angles. It is possible to get information on material properties such as: wettability, absorption, surface free energy, adsorption, spreading.

Keywords: surface, contact angle, surface tension

Preparative chromatography system

Description: Preparative chromatography system

Technical specification: Liquid or Solid Sample Modes, Solid Injection: up to 75g; 4 Independent channels with up to four solvents in a single run; Combination of up to 2 UV signals plus ELSD with slope and/or threshold detection.

Usage area: Purification of organic materials

Keywords: Flash chromatography, purification, organic materials, preparative scale

Spectrophotometer GENESYS 8

Description: Spectrophotometer GENESYS 8

Technical specification: 190-1100 nm

Usage area: Spectrophotometric analysis

Keywords: Spectrophotometry

Luminescence spectrometer Perkin Elmer LS-55

Description: Luminescence spectrometer Perkin Elmer LS-55

Technical specification: Excitation spectra wavelength range: 200-800 nm; emission spectra wavelength range: 200-650 nm.

Usage area: For recording of luminescence spectra of solutions and hard samples

Keywords: Fluorescence, phosphorescence

Drug dissolution test

Description: Drug dissolution test

Technical specification: 6 places

Usage area: Drug release studies

Keywords: Drug release

FTIR spectrometer Perkin Elmer Frontier

Description: FTIR spectrometer Perkin Elmer Frontier

Technical specification: Spectrum range: 600-4000 nm.

Usage area: For recording of FTIR spectra of hard samples

Keywords: FTIR spectra

Shrinkage temperature determination instrument

Description: Shrinkage temperature determination instrument

Technical specification: Instrument is suitable for hide/skin/leather shrinkage temeprature determination under 100 degrees.

Usage area: Instrument for leather shrinkage temperature mesearment under 100 degree (ISO 3380).

Keywords: Leather, shrinkage temperature

Leather processing equipment containing 1) apparatus for leather tanning process imitation and 2) shaker for solutions preparation

Description: Leather processing equipment containing 1) apparatus for leather tanning process imitation and 2) shaker for solutions preparation

Technical specification: Leather processing equipment containing 1) apparatus for leather tanning process imitation and 2) shaker for solutions preparation

Usage area: Equipment is suitable for leather processing in laboratory conditions and for solutions preparation for analysis

Keywords: Leather, processing, shaker

Dielectrical spectrometer Agilent E4980A Precision LCR meter

Description: Dielectrical spectrometer Agilent E4980A Precision LCR meter

Technical specification: Temperature interval: -60 - 300°C.

Usage area: Measurements of dielectrical properties of materials

Keywords: Dielectrical properties

Thermal Analyser Perkin Elmer TGA4000

Description: Thermal Analyser Perkin Elmer TGA4000

Technical specification: Temp.range 30-1000 ºC, heating rate 0.1-100 ºC/min, nitrogen or oxygen environment.

Usage area: For mass loss analysis by heating

Keywords: Thermogravimetry

Kugelrohr distillation system

Description: Kugelrohr distillation system

Technical specification: temperature range 20-200 °C, distillate volume - 1-330 ml.

Usage area: Liquids distillation under oil pump vacuum. Sample range per single run - 1-330 ml.

Keywords: kugelrohr, distillation.

Automated Soxhlet extraction

Description: Automated Soxhlet extraction

Technical specification: 2 ceramic heating plates; Extraction thimbles - 130 ml; Volume of Soxhlet glass chamber - 190 ml.

Usage area: Fat extraction for fat determination. Continuous extraction of solids.

Keywords: extraction, soxhlet

Constant climate chamber Memmert GmbH HCP-246

Description: Constant climate chamber Memmert GmbH HCP-246

Technical specification: Temp.range 20 - 90 ºC, ±0.1°C; humidity range 20-95 %, ±1%.

Usage area: Environment simulation

Keywords: Environmental simulation

Disperser IKA T 50 digital ULTRA-TURRAX

Description: Disperser IKA T 50 digital ULTRA-TURRAX

Technical specification: Speed range 600-10000 rpm; volume range 0.25-30 l

Usage area: Preparation of dispersions, emulsions

Keywords: Dispersion

Polarizing microscope (Olympus BX41) with light source and hotstage

Description: Polarizing microscope (Olympus BX41) with light source and hotstage

Technical specification: Temperature range 150-420oC; Reflection and transmission modes; Polarizator; 50, 200, 500 X magnification. LED Light source for reflection mode. Photocamera.

Usage area: The observation of phase transitions of organic materials, investigation of phase transitions of liquid crystals, observation of the surfaces.

Keywords: microscopy, polarisation, liquid crystals

Spin Coater SPS SPIN-150

Description: Spin Coater SPS SPIN-150

Technical specification: Speed 0-10000 rpm, sample max. diameter 150 mm.

Usage area: For film casting

Keywords: Film casting, spin coating

Micro Viscoamylograph Brabender

Description: Micro Viscoamylograph Brabender

Technical specification: Temp.range 1-100 ºC, sample volume 100 ml

Usage area: For investigation of pasting properties of starch derivatives

Keywords: Starch, pasting, viscosity

Melt flow rate meter Thermo C-Flow

Description: Melt flow rate meter Thermo C-Flow

Technical specification: Temp.range 50- 400 ºC, extrusion barrel: diameter 9.55 mm, length 170 mm.

Usage area: For determinastion of melt flow rate of thermoplastics

Keywords: Thermoplastics, melt flow rate

Melting point apparatus

Description: Melting point apparatus

Technical specification: Melting or boiling point range 30-400°C

Usage area: Melting point determination of crystalline compounds. Boiling point determination under atmospheric pressure.

Keywords: Melting point, boiling point

Melting point apparatus

Description: Melting point apparatus

Technical specification: Melting or boiling point range 30-400°C

Usage area: Melting point determination of crystalline compounds. Boiling point determination under atmospheric pressure.

Keywords: Melting point, boiling point

Glass oven Kugelrohr with accessories

Description: Glass oven Kugelrohr with accessories

Technical specification: Temperature range: 30-300°C. Appropriate amount of substance per cycle: 0,5-40 ml.

Usage area: For distillation, sublimation, drying, freeze drying under vacuum down to 0,01 mbar and temperature limit to 300 °C. For distillation of viscous liquids.

Keywords: kugelrohr, distillation, sublimation, drying, freeze drying.

Glass oven Kugelrohr with accessories

Description: Glass oven Kugelrohr with accessories

Technical specification: Temperature range: 30-300°C. Appropriate amount of substance per cycle: 0,5-40 ml.

Usage area: For distillation, sublimation, drying, freeze drying under vacuum down to 0,01 mbar and temperature limit to 300 °C. For distillation of viscous liquids.

Keywords: kugelrohr, distillation, sublimation, drying, freeze drying.

Turbo molecular vacuum system (end vacuum ~10 -7 mbar)

Description: Turbo molecular vacuum system (end vacuum ~10 -7 mbar)

Technical specification: End vacuum - 1•10-7 mbar; Pumping speed for N2 - 35 l/s; Compression ratio for N2 - 1·1011; External vacuum sensor; Flange (in) - 40 ISO-KF.

Usage area: Drying of solids, desorption, sublimation.

Keywords: Sublimation, drying, turbo molecular pump.

Turbo molecular vacuum system (end vacuum ~10 -7 mbar)

Description: Turbo molecular vacuum system (end vacuum ~10 -7 mbar)

Technical specification: End vacuum - 1•10-7 mbar; Pumping speed for N2 - 35 l/s; Compression ratio for N2 - 1·1011; External vacuum sensor; Flange (in) - 40 ISO-KF.

Usage area: Drying of solids, desorption, sublimation.

Keywords: Sublimation, drying, turbo molecular pump.

Spectrophotometer Konica Minolta CM-5

Description: Spectrophotometer Konica Minolta CM-5

Technical specification: Standard observer at 2° ir 10°; standard illuminant C and D65; color spaces L*a*b, L*C*h, Hunter Lab, Yxy, XYZ, Munsell and color differences

Usage area: Determination of color characteristics

Keywords: Color characteristics

Microbial Oxidative Degradation Analyzer Saida FDS Inc. MODA-6

Description: Microbial Oxidative Degradation Analyzer Saida FDS Inc. MODA-6

Technical specification: Temperature interval: 45 - 65°C; 6 reaction columns.

Usage area: Assesment of biodegradability of materials under aerobic conditions according to CO2 emission

Keywords: Biodegradability, aerobic conditions, carbon dioxide

Vacuum sublimation equipment

Description: Vacuum sublimation equipment

Technical specification: vacuum up to 0,001 mbar by LN freezing. Sublimation modules for amounts from 1 to 100 g sample of material.

Usage area: For sublimation, freeze drying, drying, removing of residual solvents of solid materials.

Keywords: sublimation, drying, freeze drying.

Preparative chromatography system Sepacore Line C-600

Description: Preparative chromatography system Sepacore Line C-600

Technical specification: Controlled pump flow rate - 2,5 – 250 ml/min; Pump working pressure limits - 0 – 50 bar; UV detection spectral range - 190 – 740 nm; UV detection limits 0,001-5 A

Usage area: Preparative chromatographic purification of organic compounds, pure compounds separation under isocratic or gradient flow. Automated purification process.

Keywords: preparative chromatography

X-ray single crystal diffraction spectrometer

Description: X-ray single crystal diffraction spectrometer

Technical specification: X-Ray power source: 50W of rays power. Double focuse optic. Detector: sensitivity not less than 175 e-/photon. Low temperature module with lowest temperature value 200K. Dry air module up to –70°C dew point and flexible airflow rate not less than 25L/min. Dynamic range > 1:20000. 16 000 000 pixels.

Usage area: Single crystal research. Determination of molecular structure.

Keywords: Single crystal, X-ray

FT-IR spektrometer

Description: FT-IR spektrometer

Technical specification: Optic range: 8000-350 cm-1. Signal-to-noise ratio >8000:1. Resolution: <0,4 cm-1. Wave length precision <0,01 cm-1 (at 2000 cm-1). Accessories for transmission measurement. Accessories for ATR measurements. ATR spectral database of industrial compounds.

Usage area: Liquid, solid and gaseous phase infrared spectral measurements. Compound search in spectral database.

Keywords: FT-IR spectrometer

FT-IR spectrometer with RAMAN module

Description: FT-IR spectrometer with RAMAN module

Technical specification: Measurement under vacuum (3,5 mbar) or under atmospheric pressure. Optical spectral range - 8000-50 cm-1. Signal-to-noise ratio - 8500:1. Resolution: >0,18 cm-1. Wavelength tolerance <0,01 cm-1 (at 2000 cm-1). Accessory for transmission measurement. Platinum ATR accessory. Compound search in spectral database. Accessory for variable temperature measurement in range -190 to +250°C. RAMANO spectra. Laser 1064 nm, emmition power 0,5 W. Resolution for RAMAN spectra >0,5 cm-1. 3D RAMAN scanning.

Usage area: Liquid, solid and gaseous phase infrared spectral measurements. Compound search in spectral database. Transmition spectral research in temperature range from -190 to +250°C. RAMAN spectra of solid and liquid compounds. 3D RAMAN scanning. Qualitative RAMAN and IR spectral analysis.

Keywords: IR, FT-IR, MID-IR, FAR-IR, RAMAN, Spectral date base, variable temperature IR

Balances for big weights, model: MSE 12201S-0CE

Description: Balances for big weights, model: MSE 12201S-0CE

Technical specification: Weighing capacity:12000g; Readability: 0,1 g; Repeatedability: ≤±0,05 g. Linearity: ±0,1 g.

Usage area: to weight metal vessel and reactors

Keywords: Balances

Analytical balances (0,001 mg) and balances table

Description: Analytical balances (0,001 mg) and balances table

Technical specification: Weighing capacity:31g; Readability: 0,001 mg; Repeatedability: ±0,002 mg. Average response time - 15 s. Pan size - Ø 30 mm.

Usage area: For precise weighing of micro analytical samples.

Keywords: Micro balances

Photochemical reactor, Ace Glass

Description: Photochemical reactor, Ace Glass

Technical specification: Volume of the reaction vessel - 250 mL; Operating volume - 125 mL; Power of light source - till 450 W.

Usage area: Radical reactions in solution

Keywords: photochemical reactor, UV

Microwave reactor with hydrogenation module, Discover LabMate, CEM

Description: Microwave reactor with hydrogenation module, Discover LabMate, CEM

Technical specification: Microwave radiation power - 300 W. Temperature regulation from - 90 °C till +300 °C. Volume of reaction vessel working at the atmospheric pressure till 125 mL. Pressure adjustment and regulation range from 0 till 20 bar. Adapter for gaseous reagents

Usage area: To perform precision chemical reactions under microwave heating and tracking pressure. The reaction with gaseous reagents or inert conditions at elevated pressure.

Keywords: microwaves, gas addition module

spincoater, Chemat Technology Spin-Coater KW-4A

Description: spincoater, Chemat Technology Spin-Coater KW-4A

Technical specification: 2-Stage spinning: 500-2500 rpm; 1000-8000 rpm. Chucks for different size substrates

Usage area: Thin film formation from solution on the substrate

Keywords: spin coating, thin film

Cyclic voltammetry apparatus (potentiostat), Bio-logic Sas SP-150

Description: Cyclic voltammetry apparatus (potentiostat), Bio-logic Sas SP-150

Technical specification: Current ranging: 10 μA to 800 mA Current resolution: 760 pA. Control voltage: ±10 V. Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V. Voltage resolution: 5 μV EIS measurement from 10 µHz to 1 MHz.

Usage area: Cyclic voltammetry, determination of oxidation reduction potentials of te organic materials

Keywords: potentiostat, CV, cyclic voltammetry

Spectrofluorimeter for measuring steady state luminescence spectra and quantum yields in the UV – NIR spectral range with single photon counting sensitivity. Spectrometer for measuring fluorescence lifetimes spanning the range from picoseconds to microseconds based on the technique of time correlated single photon counting, Edinburgh Instruments FL920

Description: Spectrofluorimeter for measuring steady state luminescence spectra and quantum yields in the UV – NIR spectral range with single photon counting sensitivity. Spectrometer for measuring fluorescence lifetimes spanning the range from picoseconds to microseconds based on the technique of time correlated single photon counting, Edinburgh Instruments FL920

Technical specification: Lifetime range: 100ps – 50μs (time correlated single photon counting). Fluorescence red sensitive detector (200 – 870nm).

Usage area: Measurement of fluorescence spectra and quantum yields of liquid and solid samples. Measurement of fluorescence lifetime of liquid and solid samples.

Keywords: fluorescence, quantum yield, fluorescence lifetime

Pressure filtration vessel

Description: Pressure filtration vessel

Technical specification: Internal diameter: 142 mm, Flow: ∆p = 1 bar for water ≥2 l/min pro 0,2 μm, ≥4,5 l/min pro 0,45 μm, ≥11 l/min pro 0,8 μm membrane Filtration area: 130 cm² Max. Working pressure: ≥7 bar

Usage area: Filtration of viscous liquids, sterile filtration

Keywords: Pressure filtration

Interferometer, MarSurf WS 1

Description: Interferometer, MarSurf WS 1

Technical specification: High-precision, non-contact measurement of surface texture. Optical surface sensor operates on the basis of white-light interferometry. This technology enables rapid, high-precision recording of surface topography on a wide range of materials. Vertical resolution 0.1 nm. Measuring range (vertical) 100 μm.

Usage area: Surface topography measurements

Keywords: interferometry, surface topography

Nanosecond laser flash photolysis measurement system

Description: Nanosecond laser flash photolysis measurement system

Technical specification: Nanosecond laser NL301G-10-SH-TH-FH (up to 10 mJ), UV-spectrophotometer IJ, fiber, UV-IJ source

Usage area: Investigations of photochromic compounds in solution using nanosecond laser pulses

Keywords: flash photolysis

Microwave reactor with hydrogenation module, Discover LabMate, CEM

Description: Microwave reactor with hydrogenation module, Discover LabMate, CEM

Technical specification: Microwave radiation power - 300 W. Temperature regulation from - 90 °C till 300 °C. Volume of reaction vessel working at the atmospheric pressure till 125 mL. Pressure adjustment and regulation range from 0 till 20 bar. Adapter for gaseous reagents

Usage area: To perform precision chemical reactions under microwave heating and tracking pressure. The reaction with gaseous reagents or inert conditions at elevated pressure.

Keywords: microwaves, gas addition module

AFRICA (Automated Flow Reaction Incubation Control Apparatus) with FLLEX and PCM.

Description: AFRICA (Automated Flow Reaction Incubation Control Apparatus) with FLLEX and PCM.

Technical specification: Completely chemically inert synthesis environment. Four independent liquid-filled pumps with a debit control from 2.5 to 2500 ul / min range. Maximum system pressure up to 20 bar. 1 1/4, 1/16 ml micro reactors with 2 or 3 of the liquid inlet. Two thermostats: 0-150 ° C and 40-250 ° C temperatures. Liquid extraction module. Reagent input module. Clean solvent was added to the module. The product manifold. Software manages the performance of chemical processes.

Usage area: Investigations of homogeneous chemical processes. Reaction performance under unusual conditions: very rapid mixing, the suspension is very fast, quick analysis, implementation absolute terms, highly exothermic reactions, the use of precise control of the reaction parameters of performance. Multistep reaction performance. Precise reaction optimization process of production. Quick extraction performance.

Keywords: micro reactor, micro extractor, flow chemistry

Schleibinger Geräte GmbH VICASONIC ultrasound apparatus

Description: Schleibinger Geräte GmbH VICASONIC ultrasound apparatus

Technical specification: 10 imp./s speed and 54kHz frequency

Usage area: investigation of cement stone properties

Keywords: ultrasound analysis

equipment of powder homogenizing WAB TURBULA T2F

Description: equipment of powder homogenizing WAB TURBULA T2F

Technical specification: mixing of Powder material of all types

Usage area: Powder material mixing

Keywords: Powder material homogenizing

sieve analysisi instrumen Sonic Sifter

Description: sieve analysisi instrumen Sonic Sifter

Technical specification: sieve from 3 µm to 5,6 mm

Usage area: sieve analysis

Keywords: sieve analysis

Netzsch 409 PC Luxx simultaneous thermal analysis instrument with ceramic sample handlers and crucibles of Pt-Rh.

Description: Netzsch 409 PC Luxx simultaneous thermal analysis instrument with ceramic sample handlers and crucibles of Pt-Rh.

Technical specification: heating rate of 15°C/min, the temperature ranged from 30°C to 1000°C under a nitrogen atmosphere

Usage area: DSC-TG analysis

Keywords: DSC-TG

Keywords: f

Fixed bed adsorption unit FBAU/EV

Description: Fixed bed adsorption unit FBAU/EV

Technical specification: CO2 reducer flow 0-1 l/min, heli - 0-5 l/min. heat element 0,5 kW

Usage area: Investigation of adsorption properties of materials.

Keywords: adsorbtion

Spray dryer MSD/EV

Description: Spray dryer MSD/EV

Technical specification: Peristaltic pump 0-1,5 l/h. 3 kW heat element. Temperature range 280 °C

Usage area: obtaining solid matter particles from suspensions

Keywords: suspension, drying

Heat transfer pilot plant with tube-in-tube, shell-and-tube and plate exchangers SCTA/EV

Description: Heat transfer pilot plant with tube-in-tube, shell-and-tube and plate exchangers SCTA/EV

Technical specification: Flowmeters 0-1000 l/h, 4-20 mA sygnal

Usage area: heat transfer processes analysis in heat exchangers

Keywords: Heat transfer

Solid-liquid extraction pilot plant SLA/EV

Description: Solid-liquid extraction pilot plant SLA/EV

Technical specification: Pump 0-12 l/h. Screw speed 0-10 min-1

Usage area: selective components of the extraction solvents extractive phase equilibrium and kinetic studies

Keywords: extraction

tray dryer apparatus TD/EV

Description: tray dryer apparatus TD/EV

Technical specification: Fan 0-1400 min-1, power 0.3 kW. 9 heat element each 300 W

Usage area: convection material drying

Keywords: drying

liquid mixing apparatus LM/EV

Description: liquid mixing apparatus LM/EV

Technical specification: Mixer 140 W, 30-1000 min-1

Usage area: liquid mixing

Keywords: liquid mixing

Filter press and micro filter pilot plant FP-1S/EV

Description: Filter press and micro filter pilot plant FP-1S/EV

Technical specification: Pump 0-128 l/h. 3 manometers 0-6 bar, 4-20 mA sygnal

Usage area: filtration of suspension with filter press and microfilter

Keywords: filtration

Centrifugal pumps in series and parallel test bench BP-1S/EV

Description: Centrifugal pumps in series and parallel test bench BP-1S/EV

Technical specification: Centrifugal pump 0-15 m3/h, 0-3000 min-1

Usage area: settings of various pump parameters

Keywords: pump

Liquid-liquid extraction pilot plant LLA/EV

Description: Liquid-liquid extraction pilot plant LLA/EV

Technical specification: Mixer 0-1000 min-1, pump 0-34 l/h

Usage area: valuable or toxic substances produced by the solutions, the concentration of the solutions.

Keywords: solution, extraction

Spectrophotometer T70, PG Instruments limited

Description: Spectrophotometer T70, PG Instruments limited

Technical specification: Wavelength 190-1100 nm; Sample Module 8 Cell

Usage area: Determination of P, Fe

Keywords: UV/VIS

Microscope Olympus SZX7 for crystals

Description: Microscope Olympus SZX7 for crystals

Technical specification: 40x zoom

Usage area: Crystal analysis

Keywords: Optical microscope, crystal analysis

Continuous distillation pilot plant DCA/EV

Description: Continuous distillation pilot plant DCA/EV

Technical specification: Heat elements 300 and 2500 W. Pump 0-12 l/h

Usage area: separation of heterogeneous mixtures of liquids

Keywords: distillation

Thin film evaporation pilot plant ESSA/EV

Description: Thin film evaporation pilot plant ESSA/EV

Technical specification: Pump 0-24 l/h. Vakuum pump 0,7 kW. 0-1500 min-1, mixer power 1 kW

Usage area: Exclusion of salt from solutions and the heat balance studies.

Keywords: evaporation

Double-effect falling-film evaporation pilot plant EDEA/EV

Description: Double-effect falling-film evaporation pilot plant EDEA/EV

Technical specification: Pump 0-34 l/h

Usage area: separation of solvent from solutions, material concentration and mass and energy transfer processes analysis

Keywords: crystallization

optical microscope Axiolmager Z2

Description: optical microscope Axiolmager Z2

Technical specification: Magnification up to 500 times.

Usage area: The study of materials surface and texture

Keywords: optical microscope

X-ray diffractometer for powder and layers ADVANCE D 8

Description: X-ray diffractometer for powder and layers ADVANCE D 8

Technical specification: Vertical goniometer, Theta/2Theta or Theta/Theta geometry. Max. usable angular range: –110° < 2Theta ≤168°. Smallest addressable increment: 0.0001°. Instrument alignment: Equal or better than ± 0.01° 2Theta; NIST SRM 1976a. Maximum angular speed 20°/s. Point detector: Scintillation counter with graphite monochromator, 1-D detector: LYNXEYE with Ni-filter.

Usage area: powder,liquids, thin films X-ray analysis

Keywords: X-ray analysis

bending testing machine

Description: bending testing machine

Technical specification: the accuracy class - 1 (DIN EN ISO 7500-1)

Usage area: bending testing machine

Keywords: Compression- and bending tests

Climatic chamber

Description: Climatic chamber

Technical specification: capacity - 350 l. humidity 60 -95 % rH. Temperature range -20ºC- 50ºC

Usage area: for environmental conditions maintenance

Keywords: Climatic chamber

Analytical electronic balance, "Radwag MXA 5", (d=1µg)

Description: Analytical electronic balance, "Radwag MXA 5", (d=1µg)

Technical specification: Maximum sample weight - 5g. Scaling value - 1μg. Weighing repeatability - `3μg.

Usage area: Sample mass measurements (0 – 5g, d=1µg).

Keywords: Analytical balance

Spectrophotometer "GENESYS 8"

Description: Spectrophotometer "GENESYS 8"

Technical specification: Wavelength range - 190-1100nm. Accuracy - <1nm.

Usage area: Sample UV-VIS spectroscopy analysis.

Keywords: UV-VIS spectroscopy analysis.

Gas chromatograph with TCD detector

Description: Gas chromatograph with TCD detector

Technical specification: Alltech CTR 1 column, maximum available operating temperature 275° C

Usage area: Quantitative and qualitative analysis of gases (O2, N2, CH4, CO2, CO)

Keywords: GC-TCD

Linseis TMA PT1000 Thermomechanical Analyzer

Description: Linseis TMA PT1000 Thermomechanical Analyzer

Technical specification: Temperature interval - from room temperature to 1000 °C; sample size - 30 mm; force - from 1 to 5.7 N; frequency - from 1 to 5 Hz

Usage area: The evaluation of changes in the sample dimensions (volume) by applying constant or alternating mechanical load while the substance is subjected to a controlled temperature program in a specified atmosphere. These tests can be performed: visco-elastic behavior, deformation, 3 point bending test, change of volume and penetration.

Keywords: Thermomechanical analysis

Differential scanning calorimeter DSC214Polyma

Description: Differential scanning calorimeter DSC214Polyma

Technical specification: Temperature interval: from -30 to 600 °C; min. heating rate - 0.001 °C/min.

Usage area: The evaluation of energy, which is needed to uniform sample`s and reference`s temperatures while the substance is subjected to a controlled temperature under specified atmosphere. This method allows to determine: specific heat, melting temperature, the change of enthalpy, glass transition temperature, decomposition temperature and other thermal conversions.

Keywords: Differential scanning calorimetry

PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Description: PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Technical specification: Aerosol concentration measurement range - 0.001 to 400.0mg/m3. Particle size range for maximum accuracy - 0.1 to 10μm.

Usage area: Measurements of personal exposure to aerosol particles in the workplace.

Keywords: Aerosol particles

Optical aerosol particle counter, Handheld IAQ 3016

Description: Optical aerosol particle counter, Handheld IAQ 3016

Technical specification: Measuring range - 0.3-10.0 µm. Flow rate - 2.83 l / min. Measuring the number of channels - 6 (0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm). The maximum instantaneous concentration - 140 particles/cm3.

Usage area: Aerosol particle dispersion composition in indoor and outdoor air (0.3 - 10.0μm).

Keywords: Aerosol particles.

Gas chromatograph with FID detector CLARUS 500

Description: Gas chromatograph with FID detector CLARUS 500

Technical specification: Alltech AT-WAX capillary column, maximum available operating temperature 260 °C

Usage area: Quantitative analysis of volatile and semi-volatile organic compounds

Keywords: GC-FID

UV/VIS spectrophotometer Lambda 25

Description: UV/VIS spectrophotometer Lambda 25

Technical specification: Measuring range from 190 to 1100 nm

Usage area: UV/VIS absorption/transmittance spectra

Keywords: UV/VIS absorption, UV/VIS transmittance

Spectrometer AANALYST400

Description: Spectrometer AANALYST400

Technical specification: D2 background correction, flame acetylene-air or acetylene-nitrous oxide

Usage area: Quantitative analysis of metal solutions by atomic absorption and atomic emission spectroscopy methods

Keywords: AAS

Autolab PGSTAT12 Potentiostat/Galvanostat 

Description: Autolab PGSTAT12 Potentiostat/Galvanostat 

Technical specification: low noise potentiostat/galvanostat capable of measuring or applying a maximum current of 250 mA, with a compliance voltage of 12 V and the possibility to do iR-compensation

Usage area: Electrochemical research, voltammetric analyses

Keywords: Electrochemical analysis

Gas chromatograph-mass spectometer CLARUS 500

Description: Gas chromatograph-mass spectometer CLARUS 500

Technical specification: Elite-5MS capillary column, maximum available operating temperature 330/360 °C

Usage area: Quantitative and qualitative analysis of volatile and semi-volatile organic compounds

Keywords: GC-MS

Mass spectometer CLARUS 500

Description: Mass spectometer CLARUS 500

Technical specification: Electron impact ionization, ionization energy 70eV

Usage area: Detector in CLARUS GC-MS system

Keywords: MS

Indoor air quality monitor "Aeroqual IQM 60"

Description: Indoor air quality monitor "Aeroqual IQM 60"

Technical specification: Gaseous pollutant name - measuring range; the lowest detection limit. CO2 - 0-2000 ppm; 6 ppm. CO - 0-100 ppm; 0.2 ppm. NO2 - 0-0.2 ppm; 0.001 ppm. VOC - 0-20 ppm; 0:01 ppm. O3 - 0-0.5 ppm; 0.001 ppm. Particle counter - 8 channels from 0.3 to 10.0μm.

Usage area: Measurements of carbon monoxide, carbon dioxide, nitrogen dioxide, ozone, volatile organic compounds, and aerosol particle concentrations at ambient and indoor air.

Keywords: Carbon monoxide, carbon dioxide, nitrogen dioxide, ozone, VOCs and PM.

PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Description: PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Technical specification: Aerosol concentration measurement range - 0.001 to 400.0mg/m3. Particle size range for maximum accuracy - 0.1 to 10μm.

Usage area: Measurements of personal exposure to aerosol particles in the workplace.

Keywords: Aerosol particles

Heating Circulators, Julabo HE-4

Description: Heating Circulators, Julabo HE-4

Technical specification: Working temperature range 20-250 °C±0.01; Volume 3-4.5 l

Usage area: Temperature control

Keywords: Thermostatation

Flame Photometer, PFP7, operating and Service Manual

Description: Flame Photometer, PFP7, operating and Service Manual

Technical specification: Limits of Detection: Na, K-0.2 ppm; Ca-15 ppm

Usage area: Determination of Ca, Na, K

Keywords: Flame photometric analysis

Programmable rapid distillation system with external titratinion, Gerhardt

Description: Programmable rapid distillation system with external titratinion, Gerhardt

Technical specification: Digestion; Distillation; Automatic titration; Combined pH electrode

Usage area: Determination of N

Keywords: Nitrogen

Laboratory centrifuge for tubes LMC-3000

Description: Laboratory centrifuge for tubes LMC-3000

Technical specification: 3000 rpm

Usage area: Wide range of analytical applications

Keywords: centrifuge

Compact Lab Fluid Bed Dryer/Granulator/Coater

Description: Compact Lab Fluid Bed Dryer/Granulator/Coater

Technical specification: Control of Spray Solution, of Air Flow, of Temperature

Usage area: Solid Material Granulation, coating

Keywords: Granules, Film

Resistance Meter

Description: Resistance Meter

Technical specification: The Measuring Range from 0,1 Ω to 20 GΩ, possibility to measure thermostated sample from -50 to 50 °C

Usage area: Measurement of surface resistance

Keywords: Surface electrical resistance, electrical conductivity

Keywords: f

High performance liquid chromatograph vith mass spectrometer

Description: High performance liquid chromatograph vith mass spectrometer

Technical specification: Separation of mixtures into individual compounds and recording of their UV and MS spectra. Maximum pressure up to 5000 psi, maximum flow rate up to 10 ml/min, UV range 200-700 nm, MS range 20-2000 m/z.

Usage area: Separation of mixtures and quantitative and qualitative analuysis of indivisual compounds

Keywords: HPLC-MS

Pocket Goniometer PG-2

Description: Pocket Goniometer PG-2

Technical specification: dimensions (LxWxH) 160x55x42 mm; integrated camera; 15 images/sec

Usage area: Determination of weting angle and surface treament level of printing and packaging materials

Keywords: Wetting angle, surface treament level

Keywords: f

Keywords: f

Zwick Roell Materials Testing Machine BDO-SBO.5TH

Description: Zwick Roell Materials Testing Machine BDO-SBO.5TH

Technical specification: fiber tension up to 100 N

Usage area: textile testing

Keywords: cyclic tension, , elongation

Spectrophotometer SF450X W/UV

Description: Spectrophotometer SF450X W/UV

Technical specification: Measuring Delta E

Usage area: textile testing

Keywords: spectrophotometer

Spectrophotometer XRite Color Digital

Description: Spectrophotometer XRite Color Digital

Usage area: Press the control parameters

Keywords: Color setting

Keywords: f

martindale testing machine

Description: martindale testing machine

Technical specification: martindale test

Usage area: textile testing

Keywords: abrasion, pilling

Microscope DPM 300

Description: Microscope DPM 300

Technical specification: Resolution 1280 x 1024 Pixels

Usage area: Image Analysis Software with Digital Pocket

Keywords: Automatic Image Analysis

Zwick Roell Materials Testing Machine

Description: Zwick Roell Materials Testing Machine

Technical specification: tension up to 5kN

Usage area: Textiles testing

Keywords: cyclic tension, friction, elongation

Keywords: f

InfraCAM SD

Description: InfraCAM SD

Technical specification: Accuracy 2%; 25°x25° field of view; thermal sensitivity 0,12°C; temperature measurment range -10°C÷ 350°C

Usage area: Control of printing technological process and quality

Keywords: Thermovision, printing quality control

KPP Flexo Proofer

Description: KPP Flexo Proofer

Technical specification: Printing speed up to 40 m/min; print size 400x500 mm

Usage area: Flexo proofing on flexible materials

Keywords: Flexography, proofing

Friction/peel tester

Description: Friction/peel tester

Technical specification: Load cell 0.5-2 kg; measurement accuracy ±0.25%; testing speed up to 20 mm/min

Usage area: Determination of paper/film friction coefficient; peel researches of adhesive materials

Keywords: Friction coefficient; peel

Stand of granular solid fuel burining test

Description: Stand of granular solid fuel burining test

Usage area: Only for the study process

Keywords: f

Paste Ink Proofer

Description: Paste Ink Proofer

Technical specification: Print size 75x245 mm; printing speed 5-40 m/min; pressing 0-150 N/cm

Usage area: Proofing on paper

Keywords: Proofing

FAG BRAI³ Braille Dot Checker

Description: FAG BRAI³ Braille Dot Checker

Technical specification: Camera 1.3 MPixel BW 0 USB2.0, resolution of 1.7 μm / pixel, field of view of 2.2 mm × 1.8 mm rectangular form

Usage area: Braille geometrical parameters

Keywords: Braille dot

Keywords: f

Keywords: f

Keywords: f

Keywords: f

Keywords: f

Hardness tester

Description: Hardness tester

Technical specification: Vickers micro hardness

Usage area: hardness measurement

Keywords: hardness measurement

Keywords: f

Keywords: f

Extensometers

Description: Extensometers

Technical specification: Measuring base 25 mm

Usage area: Measurement of strain s

Keywords: strain, measurment

Laser centering device

Description: Laser centering device

Technical specification: centering in 2 planes

Usage area: centering of shafts

Keywords: centering of shafts

Optical Motion Capture system for measurements and analysis of movements CONTEMPLAS (two digital videocameras, software for measurements and data processing)

Description: Optical Motion Capture system for measurements and analysis of movements CONTEMPLAS (two digital videocameras, software for measurements and data processing)

Technical specification: Two digital videocameras (mini DV camcorders Panasonic NV-GS330, 3CCD), synchronically transmitting the view of the object marked with light reflecting markers to the personal computer with dada processing software Templo Standart; set of spherical light reflective markers

Usage area: Measurements and analysis of movements of mechanical and biomechanical systems, (gait analysis, work, sports or casual activities etc.)

Keywords: Biomechanics, Motion capture, Videocamera, Marker

microscope

Description: microscope

Technical specification: up to 500x

Usage area: metalogrphic analysis

Keywords: metalogrphic analysis

Keywords: f

Keywords: f

Keywords: f

Hardness tester

Description: Hardness tester

Technical specification: Vickers, Rockwell, Brinell

Usage area: hardness measurement

Keywords: hardness measurement

Insulation agains heat apparatus IG/ISOC (f. GIULIANI), Nr. 13917

Description: Insulation agains heat apparatus IG/ISOC (f. GIULIANI), Nr. 13917

Technical specification: The temperature of the hot plate of 150 oC

Usage area: Determination of insulation agains heat according to LST EN ISO 20344

Keywords: Insulation agains heat

Water vapour permeability test equipment STM 473 (SATRA), Nr. 473-5-0512:

Description: Water vapour permeability test equipment STM 473 (SATRA), Nr. 473-5-0512:

Technical specification: Rotation frequency of 75 min-1

Usage area: Determination of water vapour permeability according to LST EN ISO 20344

Keywords: Water vapour permeability

Bally penetrometer STM 703 (f. SATRA), Nr. 703-1-0512

Description: Bally penetrometer STM 703 (f. SATRA), Nr. 703-1-0512

Technical specification: Diameter of cylinders of 30 mm

Usage area: Measuring the dynamic water resistance of leathers according to LST EN ISO 20344; LST EN 13518

Keywords: Water penetration, water absorption

Multifunctional device Test 445

Description: Multifunctional device Test 445

Technical specification: Humidity measuring range 0-100%; Pressure measurement range 0-2000 hPa; Temperature measurement range -30-200 ° C;

Usage area: Environmental parameters of temperature, pressure, humidity measurement

Keywords: Temperature, pressure, humidity.

Electrodynamic Vibration Excitter systems

Description: Electrodynamic Vibration Excitter systems

Technical specification: Max acceleration - 92 m/s2; Max speed 1300 mm / s; Max displacement (double amplitude) -19000 μm ¶. Vibration frequency range 5-5000 Hz.

Usage area: Vibration excitation of the vibration and shock tests. Environmental testing in accordance with the standards LST EN 60068-2-6:2008 (sinusoidal vibration), LST EN 60068-2-64:2008 ( broadband random vibration ), LST EN 60068-2-27:2009 (Shock).

Keywords: Exciters, vibrations

Elecrical resistance testing instrument (PEGASIL/ZIPOR), No. 50.130

Description: Elecrical resistance testing instrument (PEGASIL/ZIPOR), No. 50.130

Technical specification: Insulation resistance 10 Ω … 3 GΩ with measuring voltage 0 … 490 V DC

Usage area: Determination of electrical resistance according to LST EN ISO 20344

Keywords: Electrical resistance

Impact tester (PEGASIL/ZIPOR), Nr. 50.130

Description: Impact tester (PEGASIL/ZIPOR), Nr. 50.130

Technical specification: Impact energy: 0 ... 200 J, Striker: mass of 20 kg , The striker consist of the faces of which subtend an angle of 90o.

Usage area: Measurement of the impact resistance according to LST EN ISO 20344; LST EN 12568

Keywords: Impact resistance

Water vapour absorption test apparatus STD 478 (f. SATRA), Nr. 478-6-0512

Description: Water vapour absorption test apparatus STD 478 (f. SATRA), Nr. 478-6-0512

Technical specification: Volume of container of 100 cm3, internal diameter of 3.5 mm

Usage area: Determination of water vapour absorption according to LST EN ISO 20344

Keywords: Water vapour absorption

Mixer Automax 5l

Description: Mixer Automax 5l

Technical specification: till 5 liters

Usage area: For cement mortar and plaster mix

Keywords: Grout, gypsum

Mask aligner MA-750

Description: Mask aligner MA-750

Technical specification: Wavelength: 360-440 nm, exposure area up to 150 mm (round)

Usage area: Mask alignement, UV exposure

Keywords: UV light, exposure

Electron beam lithography, electron microscope, energy dispersive spectroscopy

Description: Electron beam lithography, electron microscope, energy dispersive spectroscopy

Technical specification: Field emission cathode, acceleration voltage variable from 20 V to 30 kV, laser interferometer, dry vacuum system, sample size up to 102x102 mm, electron microscope, surface chemical analysis from Be (Z=4) to Am (95)

Usage area: Nanolithography, electron microscopy, surface chemical analysis

Keywords: Nanolithography, scanning electron microscopy, surface chemical analysis, EDX, EBL, EDS

Optical microscope NIKON (analyzer)

Description: Optical microscope NIKON (analyzer)

Technical specification: Magnification up to x1200, uncertainty of measurements do not exceeds (0.1 L/500) µm, where L is length of the structure under measurement.

Usage area: Measurement of linear dimensions of the transparent structures in manual and automatic modes with high fidelity

Keywords: Optical microscope, manual and automatic modes

Scale KERN PLE 310-3N

Description: Scale KERN PLE 310-3N

Technical specification: Max. weight 310 g, accuracy 0.001 g

Usage area: Weighing

Keywords: Mass, weighing

UV-VIS spektrometer

Description: UV-VIS spektrometer

Technical specification: UV-VIS spektrometer. Spekctral range 360-860 nm, spectral resolution 1.2 nm, USB2

Usage area: Reflection, transmission, absorption measurements in UV-VIS spectral range. Applied in refractive index kinetics measurement stand

Keywords: UV-VIS spectrometer

The fiber-optic spectrometer AvaSpec-2048

Description: The fiber-optic spectrometer AvaSpec-2048

Technical specification: Light source - deuterium and halogen. The spectral region 172-1100 nm, resolution - 1.4 nm. USB2

Usage area: Reflection, transmission, absorption measurements in UV-VIS-NIR spectral range. Liquids can be analyzed in the standard cell, hard transparent (measured transmission and the absorption) or vague (measured reflection) samples

Keywords: UV-VIS-NIR spektrometer

Optical and fluorescence microscope

Description: Optical and fluorescence microscope

Technical specification: Wide field oculars, digital imaging, UV fluorescence source

Usage area: Optical and fluorescence microscopy

Keywords: Optical microscope, fluorescence microscope

Lloyd`s mirror holographic lithography setup.

Description: Lloyd`s mirror holographic lithography setup.

Technical specification: Loyd`s mirror holographic lithography setup. The setup is capable to pattern structures with periods less than 500 nm

Usage area: Holographic lithography, micro-fabrication

Keywords: Laser, UV, holographic lithography, periodical structures, diffraction gratings, interference lithography, lithography, one dimensional, two dimensional three dimensional

Spincoater, hotplate and UV curing lamp for formation of thin films

Description: Spincoater, hotplate and UV curing lamp for formation of thin films

Technical specification: Two step spin-coating process (first 2-18 s, second 3-60 s) with two different speed intervals (first 500-2500 rpm, second 1000-8000 rpm). Hot plate temperature 30-300 deg C, sample size up to 6 inch, temperature resolution 0.1 deg C. UV lamp has 4x6W bulbs, wavelengths 264 nm, 365 nm. The sample up to 4 inch is rotated at 6 rpm.

Usage area: Spin-coater, hotplate, UV curing, thin layer deposition

Keywords: spin-coater, hotplate, UV lamp, thin layers, spin coating, layer formation, UV hardening, UV cross linking, drying

Atomic force microscope NT-206

Description: Atomic force microscope NT-206

Technical specification: operating modes: contact, tapping, non-contact. Lateral magnetic force microscopy. Static / Dynamic force spectroscopy. AFM characteristics: maximum scan field: 15x15μm; measurement matrix to 512x512 pixels, maximum height measurements are 2 micrometers, up to 15 mm in diameter and 5 mm high samples.

Usage area: For study the morphology and local mechanical properties of differents materials surfaces at the nano, micro-scale.

Keywords: AFM, scaning, morphology, topography

Universal optical spectroscopy and laser microfabrications system

Description: Universal optical spectroscopy and laser microfabrications system

Technical specification: Yb:KGW laser wavelength is 1030 nm, power 4W, pulse duration 290 fs, energy >0.2 mJ. Fabrication can be performed employing focused first harmonic (1030 nm) second harmonic (515 nm) or third harmonic (3436 nm) of the laser. Fabrication with controlled period (0.8-1.3 um) interference field of second harmonic (515 nm) is alse available in the system. Microfabrication can be performed in 160x160 mm area with 300 nm positioning precision. Speed of the XY tables is up to 300 mm/s, sample wight up to 3 kg. The pump wavelength range of the spectroscopic system is 315-2600 nm, the probe wavelength range is 480-1100 nm. Time resolution 16.67 fs, length of the delay line 1,8 ns, absorbtion detection limit 0.5 mOD

Usage area: Material mikro-/nano- fabrication with focused beam and measurements of absorbtion kinetics.

Keywords: Femtosecond laser, ultra fast laser, laser microfabrication, micromachining, ablation, laser drilling, laser marking, laser engraving, galvoscanner, second harmonic, third harmonic, direct ablation with interference field, holographic lithography, 515, 315, 1030, kinetic spectroscopy, pump-probe spectroscopy, differential absorption spectrometer, differential absorption, ultra fast spectroscopy

Energy dispersive X-Ray analysis

Description: Energy dispersive X-Ray analysis

Technical specification: Detectable elements from Boron (5) to Americium (95). Energy resolution 133 eV (Mn K alfa). Spatial resolution < 1 um3. Thermoelectric cooling.

Usage area: Determination of chemical composition , elemnt mapping

Keywords: Chemical composition, energy dispersion, element mapping, microanalysis, x-ray energy dispersion spectrometer, chemical element analysis, chemical element distribution, EDS, EDX

microwave plasma enhanced chemical vapor deposition system

Description: microwave plasma enhanced chemical vapor deposition system

Technical specification: plasma source diameter 6", power 6 kW frequeency 2.45 GHz homogeneous deposition area diameter 5 cm

Usage area: thin film and coating deposition

Keywords: thin film and coating deposition

Quartz dilatometer OKB-5A14

Description: Quartz dilatometer OKB-5A14

Technical specification: temperatures up to 800 C, the dimension dependence from temperature automatic recording

Usage area: glass material thermal expansion study

Keywords: glass thermal expansion

Fourier transform infrared spectrometer

Description: Fourier transform infrared spectrometer

Technical specification: Fourier transform infrared spectrometer spectra region 400-4000cm-1 Resolution - 1 cm -1. Measurement mode - transmittance, 30-degree reflection, diffuse reflection, total internal reflection (ATR)

Usage area: Characterization of molecules and mixtures, vibrational spectra identification. May be performed thin films, powders, liquid state materials research

Keywords: FTIR spektroskopy

Device for galvanoplastic multiplication

Description: Device for galvanoplastic multiplication

Technical specification: Formation of Ni film on polymeric surface

Usage area: Fabrication of Ni replica matrix with submicron (nanometric) precision and high diffraction efficiency of the final product.

Keywords: Galvanoplastic

vacuum evaporation unit

Description: vacuum evaporation unit

Technical specification: E-beam gun power up to 5 kW

Usage area: vacuum evaporation

Keywords: vacuum evaporation

Device for replication of holograms

Description: Device for replication of holograms

Technical specification: Formation of relief with submicron (nanometric) dimensions on polymer surface.

Usage area: Formation of micro-relief on polymer surface

Keywords: Micro-relief

Rockwell hardness meter

Description: Rockwell hardness meter

Technical specification: loads 15,30,45 kgf

Usage area: hardness measurement

Keywords: hardness measurement

dynamic microhardness meter

Description: dynamic microhardness meter

Technical specification: loads 0.1 – 2000 mN

Usage area: microhardness and Young modulus testing

Keywords: microhardness and Young modulus testing

solar spectra simulator

Description: solar spectra simulator

Technical specification: AM1.5

Usage area: measurement of photovoltaic properties

Keywords: measurement of photovoltaic properties

Laborat mixer. concrete mixtures

Description: Laborat mixer. concrete mixtures

Technical specification: till 30 liters

Usage area: For concrete and mortar mix

Keywords: Concrete, mortar

vacuum evaporation unit

Description: vacuum evaporation unit

Technical specification: E-beam gun power up to 5 kW

Usage area: vacuum evaporation

Keywords: vacuum evaporation

RF reactive ion etching system

Description: RF reactive ion etching system

Technical specification: power 3kW, homogeneous etching area diamater 15 cm

Usage area: reactive ion etching, surface microfabrication

Keywords: reactive ion etching, surface microfabrication

diamond like carbon ion beam synthesis system

Description: diamond like carbon ion beam synthesis system

Technical specification: ion energy 400-1000 eV

Usage area: diamond like carbon deposition

Keywords: diamond like carbon deposition

ion etching system

Description: ion etching system

Technical specification: homogeneous etching area diamater 8 cm

Usage area: ion beam etching, surface microfabrication

Keywords: ion beam etching, surface microfabrication

vacuum evaporation unit

Description: vacuum evaporation unit

Technical specification: E-beam gun power up to 5 kW

Usage area: vacuum evaporation, magnetron sputtering

Keywords: vacuum evaporation, magnetron sputtering

Vacuum pump GVP 140

Description: Vacuum pump GVP 140

Technical specification: 0 - 1 bar; 550 W; 2690 rot./min

Usage area: Core drilling machine

Keywords: wring

Laser engraving and laser cutting machines Winter Lasermax

Description: Laser engraving and laser cutting machines Winter Lasermax

Technical specification: Working area X, Y 500 x 300 mm, power 1000 W

Usage area: cutting depth abhänig of material, ideal for wood, ceramic, glass and plastic

Keywords: Cutting, mashine, engraving

MFT/3 Multifunction Table

Description: MFT/3 Multifunction Table

Technical specification: Max. working width (with FS Guide Rail) 700 mm Max. workpiece thickness (with FS Guide Rail) 78 mm Table dimensions1157 x 773 mm Weight 28 kg Work space 1102 x 718 mm Working height [folded down] 900 mm [180 mm]

Usage area: Can easily be carried to a jobsite, due to its compact size and light weight. Accurate and repeatable cuts with the guide rail and plunge saw or routers. Clamp faster with uniform holes and Festool clamps. Use with legs folded out, at full height, or folded in and set on the floor.

Keywords: Table, clamping, fixation.

Concrete Rheometer BTHREOM 789A-06-09bis two 10/10/06

Description: Concrete Rheometer BTHREOM 789A-06-09bis two 10/10/06

Usage area: For rheological properties of mortar

Keywords: Grout, rheological characteristics

Bench-mounted router TF 2200-Set

Description: Bench-mounted router TF 2200-Set

Technical specification: Power consumption 2200 W Idle engine speed 10000-22000 min-1 Max. cutter diameter 60 mm

Usage area: Simple routing height adjustment with a crank handle Arched routing hood for safe routing and optimised extraction Dual extraction connector Router module can be replaced by further CMS modules

Keywords: Table, milling machine, cutting

Thermal anenometer

Description: Thermal anenometer

Technical specification: 0... 20m/s, -20.. 70C

Usage area: Flow velosity, temperature

Keywords: Flow velosity, temperature

Digital Hand-Tachometer

Description: Digital Hand-Tachometer

Technical specification: 1,00-99999 rpm

Usage area: Tachometer

Keywords: Tachometer

Airflow meter

Description: Airflow meter

Technical specification: 1-80m/s, 4000 Pa

Usage area: Measuring air velocity wih Pitot tubes

Keywords: Pitot tubes

CO2, CO meter

Description: CO2, CO meter

Technical specification: CO 0-500ppm, CO2 0-5000ppm

Usage area: CO2, CO meter

Keywords: CO2, CO

Flow velocity, temperature meter

Description: Flow velocity, temperature meter

Technical specification: 0...20m/s, 0...50C

Usage area: Flow velosity, temperature

Keywords: Flow velosity, temperature

Technical specification: 0,6..40m/s, 0… 2000hPa

Usage area: Pressure, flow velocity, temperature meter

Keywords: Pressure, temperature

CO2 meter

Description: CO2 meter

Technical specification: 0...9,999ppm CO2

Usage area: measuring indoor air quality

Keywords: CO2

Humidity / temperature meter

Description: Humidity / temperature meter

Technical specification: 10... 60С, 0..100%HR

Usage area: Humidity / temperature measuring instryment

Keywords: Humidity, temperature

Airflow meter

Description: Airflow meter

Technical specification: 0.3 to 20 m/s

Usage area: Air velocity meter

Keywords: Air velocity

Thermal imaging camera

Description: Thermal imaging camera

Technical specification: sensitivity of <.07C at 30C (70mk)

Usage area: Thermal imager for building

Keywords: infrared detector

Technical specification: 0,05...5m/s, -0,02m/s

Usage area: Air temperature and low air velocity meter

Keywords: low air velocity

sound level meterTesto 815

Description: sound level meterTesto 815

Technical specification: 32...130 dB, 0.1dB

Usage area: Sound level meter

Keywords: sound level, monitoring

Automatic device Nr.E040 Vic-01 * 15 * 03

Description: Automatic device Nr.E040 Vic-01 * 15 * 03

Technical specification: interval from 30s till 30 min

Usage area: Cement and plaster setting start and end of the set

Keywords: Cement mortar

Vibration lot CMŽ-539

Description: Vibration lot CMŽ-539

Technical specification: none

Usage area: Concrete specimens to vibrate

Keywords: Concrete samples

Electronic weighing scales

Description: Electronic weighing scales

Technical specification: from 0 till 1,2 kg, ±0,01g

Usage area: Weighing

Keywords: Weighing

Universal drilling crown REMS 102x420xUNC

Description: Universal drilling crown REMS 102x420xUNC

Technical specification: Ø100

Usage area: Drill for Kerns

Keywords: Concrete, drilling

PRESS MC-500

Description: PRESS MC-500

Technical specification: from 0 till 500 kN

Usage area: Samples of concrete crushing

Keywords: Concrete samples

Standard fittings finder

Description: Standard fittings finder

Usage area: Reinforcement in concrete Finder

Keywords: Rebar, concrete

Device to determine the amount of air in the concrete

Description: Device to determine the amount of air in the concrete

Technical specification: from 0 till 100 percents

Usage area: Air content of concrete mixture

Keywords: Cement mortar

Universal drilling crown REMS 152x420xUNC

Description: Universal drilling crown REMS 152x420xUNC

Technical specification: Ø150

Usage area: Drill for Kerns

Keywords: Concrete, drilling

Universal drilling crown REMS 52x420xUNC

Description: Universal drilling crown REMS 52x420xUNC

Technical specification: Ø50

Usage area: Drill for Kerns

Keywords: Concrete, drilling

PRESS P-250

Description: PRESS P-250

Technical specification: from 0 till 2500 kN

Usage area: Samples of concrete crushing

Keywords: Concrete samples

Finder dense reinforcement

Description: Finder dense reinforcement

Usage area: Reinforcement in concrete Finder

Keywords: Rebar, concrete

Modulus of elasticity and deformation measure

Description: Modulus of elasticity and deformation measure

Technical specification: from 0 till 50 mm

Usage area: Modulus of elasticity and deformation measure

Keywords: Elasticity, deformations

Press GRM-2A

Description: Press GRM-2A

Technical specification: from 0 till 1000 kN

Usage area: Concrete crushing and bend samples

Keywords: Concrete samples

Tension press P -50

Description: Tension press P -50

Technical specification: from 0 till 500 kN

Keywords: Elasticity, deformations

Finder thick coating

Description: Finder thick coating

Usage area: Reinforcement in concrete Finder

Keywords: Rebar, concrete

Stereometrical Microscope STEDDY-T

Description: Stereometrical Microscope STEDDY-T

Technical specification: from 1x till 80x

Keywords: f

The unit size of the elastic rebound Proceq Silver Shmidt

Description: The unit size of the elastic rebound Proceq Silver Shmidt

Technical specification: Concrete strength mesurement from 10 till 170 Mpa

Usage area: Concrete tensile strength of the bounce method

Keywords: Concrete samples

Digital scleometer

Description: Digital scleometer

Technical specification: Concrete strength mesurement from 10 till 70 Mpa

Usage area: Concrete tensile strength of the bounce method

Keywords: Concrete samples

Meter digital resistance RESI

Description: Meter digital resistance RESI

Technical specification: 4 point resistivity mesurement. Specific resistivity ρ, from 0 till 20 kΩ.cm,

Usage area: Concrete tensile strength of the bounce method

Keywords: Concrete samples

Thermal imaging camera

Description: Thermal imaging camera

Technical specification: sensitivity of <.07C at 30C (70mk)

Usage area: Thermal imager for building

Keywords: infrared detector

Chamber for the climatic tets

Description: Chamber for the climatic tets

Technical specification: none

Usage area: Pressure, flow velocity, temperature meter

Keywords: Pressure, temperature

Ultrasonic tester for concrete researches

Description: Ultrasonic tester for concrete researches

Technical specification: For mesurement strength and defects (cracks). Crack width till 180mm

Usage area: Concrete researches

Keywords: Concrete samples

Freezing chamber KHC-2 N10032

Description: Freezing chamber KHC-2 N10032

Technical specification: till -20°C

Usage area: Materials frost resistance testing

Keywords: Materials Research

Refrigeration unit "BITZER" 2Cl 3.2

Description: Refrigeration unit "BITZER" 2Cl 3.2

Technical specification: till -20°C

Usage area: Materials frost resistance testing

Keywords: Materials Research

Swelling CAMERA BUY-1

Description: Swelling CAMERA BUY-1

Technical specification: iki 80°C

Usage area: Concrete curing specimens

Keywords: Materials Research

Cooling cabinet T-25/1

Description: Cooling cabinet T-25/1

Technical specification: from 20°C till -20°C

Usage area: Materials frost resistance testing

Keywords: Materials Research

Tension machine P -50

Description: Tension machine P -50

Technical specification: from 0 till 5 kN

Usage area: Concrete crushing and bend samples

Keywords: Concrete samples

TAM AIR III calorimeter.

Description: TAM AIR III calorimeter.

Technical specification: The range of measurement 600 mW, the sensitivity of the signal 4 ìW, the time constant 500 s,

Usage area: measurement of heat flow of processes

Keywords: calorimetric analysis

vibrating disc mill Pulverisette 9

Description: vibrating disc mill Pulverisette 9

Technical specification: ground particle size < 80 µm

Usage area: Rigid materials grinding (ability to reach ground particle size of <80 microns)

Keywords: Rigid materials grinding

The hydraulic compression testing machine

Description: The hydraulic compression testing machine

Technical specification: max. Compression force 1200 kN

Usage area: Determination of compressive and flexural strength of binding materials

Keywords: The compressive and flexural strength

CILAS 1090 LD laser scattering particle size distribution analyzer

Description: CILAS 1090 LD laser scattering particle size distribution analyzer

Technical specification: Size of measured particles 0,04-500 µm

Usage area: The particle size distribution

Keywords: The particle size distribution

Vibration lot Nr.E130 * 4 * 03

Description: Vibration lot Nr.E130 * 4 * 03

Technical specification: fall freely from a height 15±0,3 mm; one period of jolting of (60±3) s comprises exactly 60 jolts.

Usage area: Brand of cement set

Keywords: Cement mortar

Sepacore Basic Flash System, Buchi Labortechnik

Description: Sepacore Basic Flash System, Buchi Labortechnik

Technical specification: recorder, UV detector, sample inlet block, manifold, column KX16

Usage area: Proteins isolation

Keywords: Ion exchange chromatography

Works with KT1000130M HPLC

Description: Works with KT1000130M HPLC

Technical specification: Works with KT1000130M HPLC

Usage area: Works with KT1000130M HPLC

Keywords: UV

Elcometer GG013

Description: Elcometer GG013

Technical specification: Can be obtained reinforcement and it`s diameter till 180mm width

Usage area: Reinforcement in concrete Finder

Keywords: Rebar, concrete

Meat and fish texture modeling equipment

Description: Meat and fish texture modeling equipment

Technical specification: Manual hand injector Ingmat. Suitable for bone in and boneless product. Powerful self priming plastic pump Handy

Usage area: Meat and fish texture modeling

Keywords: Meat and fish technology

Spin coater for the formation of thin layers

Description: Spin coater for the formation of thin layers

Technical specification: Spin speed up to 10000 rpm, duration 1-999 s, temperature 50 - 250ºC, area up to 230x230 mm

Usage area: Thin film formation

Keywords: Spin coating, thin polimer films, photolithography, drying

UV laser

Description: UV laser

Technical specification: Wavelength 375nm, power 15 mW

Usage area: Holographic lithography, micro-fabrication

Keywords: Laser, UV, holographic lithography, periodical structures, diffraction gratings, interference lithography, lithography, one dimensional, two dimensional three dimensional

High performance liquid chromatograph

Description: High performance liquid chromatograph

Technical specification: chromatographic separation of mixtures Maximum pressure up to 5000 psi, maximum flow rate up to 10 ml/min, UV range 190-500 nm.

Usage area: quantitative analysis of individual compounds in mixtures

Keywords: HPLC

Laboratory equipment erudite MklV

Description: Laboratory equipment erudite MklV

Technical specification: Concrete modulus of elasticity mesurement from 5 till 120 Gpa

Usage area: Non-destructive method to investigate structures

Keywords: Concrete samples

CE440 Elemental Analyser

Description: CE440 Elemental Analyser

Technical specification: Accuracy: With standard organic compounds, ±0.15% absolute plus ±0.15% relative Sample Size: Typically 1-5 mg; up to 500 mg for samples with low carbon content Analysis Time: Less than 5 minutes for CHN Range: 100 ppm to 100% Detector: Thermal conductivity System Sensitivity: ±1 microvolt Analytical Sensitivity: Less than 1 microgram

Usage area: combustion analysis

Keywords: combustion analysis

Analytical balances

Description: Analytical balances

Technical specification: Weighing capacity: 220/100; Readability: 0,1/0,01 mg; Repeatedability: ≤±0,02/0,1 mg. Linearity: ≤±0,03/0,2 mg.

Usage area: weighing of samples for analysis

Keywords: balances, analytical

Benchtop chemical crystallography system XtraLab mini (Rigaku)

Description: Benchtop chemical crystallography system XtraLab mini (Rigaku)

Technical specification: Mercury CCD detector, power 600W

Usage area: investigation of monocrystals of organic and inorganic materials, study of crystal cage, identification of the chemical structure

Keywords: monocrystal, crystal cage, x-ray diffraction

Ultrasound generator K8-1

Description: Ultrasound generator K8-1

Technical specification: Ultrasound frequenz 850kHz

Usage area: For dispersion of materials of liquid materials

Keywords: Ultrasound, generator

Absorption pilot plant ADSA/EV

Description: Absorption pilot plant ADSA/EV

Technical specification: Gas reducers 0-600 Nl/h and 0-6000 Nl/h. Pump 0-270 l/h

Usage area: Excretion of components of gas mixtures, gas cleaning from harmful impurities, gas drying, gas and liquid phases of the system equilibrium and kinetics.

Keywords: Absorption

One-handed planer EHL 65 EQ Plus

Description: One-handed planer EHL 65 EQ Plus

Technical specification: Power consumption 720 W Rotational speed 15600 min-1 Planing width 65 mm

Usage area: Trimming work Assembly work Planing carcasses, trim, skirting, infill panels, doors, etc. Applications where convenient one-handed operation is required

Keywords: Molding, installation

Potentiostat/Galvanostat BioLogic SP-150 for fundamental electrochemistry, sensors, corrosion, energy sources coatings investigations

Description: Potentiostat/Galvanostat BioLogic SP-150 for fundamental electrochemistry, sensors, corrosion, energy sources coatings investigations

Technical specification: Current ranging: from 10 µA to 1 A and from 1 µA to 1 nA; Control voltage: ±10 V; EIS: 10 µHz to 1 MHz

Usage area: Fundamental electrochemistry, Sensors, Corrosion, Energy sources, Coatings investigations

Keywords: Potentiostat-galvanostat, electrochemical impedance spectroscopy

The test machine compression / bending Pilot 4

Description: The test machine compression / bending Pilot 4

Technical specification: from 0 till 3000 kN

Usage area: Concrete crushing and bend samples

Keywords: Concrete samples

The device is sealed character of steel fiber concrete specimens to detect

Description: The device is sealed character of steel fiber concrete specimens to detect

Technical specification: Determination of fiber in concrete. Units in % or in kg

Usage area: Determination of fiber in concrete

Keywords: Samples, steel

Equipment of Dairy Mechanical Processing

Description: Equipment of Dairy Mechanical Processing

Technical specification: Separator (max. capacity: 40 l/val; max. rotating speed: 8500 min-1); homogenisator (flow rate: 10-22 l/h; pressure: till 1000 bar; stages: two); butter churn (working capacity: 4-12 l; working rotation speed: 140 rpm)

Usage area: Separator is used for separation of lipids from raw milk; homogenisator - for preparation of homogeneous emulsions and splitting of milk fat droplets; butter churn - for production of butter and spreads

Keywords: Separation; Homogenisation; Butter churning

Portable moisture meter GMH 3830

Description: Portable moisture meter GMH 3830

Technical specification: Solid material moisture meter from 0 till 99%

Usage area: Moisture measurements

Keywords: Researches

Blein device Model 1,0290E

Description: Blein device Model 1,0290E

Technical specification: 220 V; 50 Hz; A distance of sample height 15 ± 1 mm;Principle of operation - semi-automatic

Usage area: Material fineness setting

Keywords: Materials Research

UV/VIS spectrophotometer Lambda 35

Description: UV/VIS spectrophotometer Lambda 35

Technical specification: Measuring range from 190 to 1100 nm, the ability to measure the surface reflection spectra

Usage area: UV/VIS absorption/transmittance, surface reflectance spectra

Keywords: UV/VIS absorption, UV/VIS transmittance, UV/VIS surface reflectance

UV/VIS spectrophotometer Lambda 25

Description: UV/VIS spectrophotometer Lambda 25

Technical specification: Measuring range from 190 to 1100 nm

Usage area: UV/VIS absorption/transmittance spectra

Keywords: UV/VIS absorption, UV/VIS transmittance

Device for multiplication of optical security marks MSM-1

Description: Device for multiplication of optical security marks MSM-1

Technical specification: The adhesive layer formation on silicone paper and multilayer polymeric film. Formation speed in the range of 1-6 m/min. Adhesive layer thichness in the range of 1-150 mm. Ability to cut out labels.

Usage area: Fabrication of optical document security intellectual property measures with micro-diffractive elements.

Keywords: Adhesive layer formation

Device for cheking depreciation (abrasion) LKI -3

Description: Device for cheking depreciation (abrasion) LKI -3

Technical specification: 70x70 mm

Usage area: The strength of materials dylumui

Keywords: Materials Research

Keywords: f

Tensiometer equipped with Vilhelmy plate and DoNuoring systems

Description: Tensiometer equipped with Vilhelmy plate and DoNuoring systems

Technical specification: Measurements range 1 - 999 mN/m

Usage area: Surface and interfase surface tension measurements

Keywords: Surface tension, interfase surface tension

Keywords: f

Atomic Absorption Spectrometer Perkin Elmer Model 403

Description: Atomic Absorption Spectrometer Perkin Elmer Model 403

Technical specification: double-beam spectrometer using the flame method. It can analyze about 30 heavy elements. The sensitivity of 0.05-0.1 ppm.

Usage area: used in many areas: water, soil and rock samples. Because of its simplicity, speed and accuracy of this method of analysis is one of the most commonly used in the determination of trace metals.

Keywords: concentration, quantitative analysis

Abrasion Resistance Tester IG/ABR/DIN (f. GIULIANI), Nr. 13916

Description: Abrasion Resistance Tester IG/ABR/DIN (f. GIULIANI), Nr. 13916

Technical specification: Diameter of wheel of 150 mm, rotating frequency of 40 mm-1, load weight of 10 N,

Usage area: Determination of abrasion resistance using a rotating wheel according to LST EN 12770; ISO 4649

Keywords: Abrasion resistance

Device of determination of paper (paperboard) surface smoothness

Description: Device of determination of paper (paperboard) surface smoothness

Technical specification: Dimensions of specimens 70x70, pressing 100 kPa ± 2 kPa; pressure above 50,7 kPa

Usage area: Determination of paper (paperboard) surface smoothness

Keywords: Surface smoothness

Electrodynamic Vibration Excitter systems

Description: Electrodynamic Vibration Excitter systems

Technical specification: Max acceleration - 92 m/s2; Max speed 1300 mm / s; Max displacement (double amplitude) -19000 μm ¶. Vibration frequency range 5-5000 Hz.

Usage area: Vibration excitation of the vibration and shock tests. Environmental testing in accordance with the standards LST EN 60068-2-6:2008 (sinusoidal vibration), LST EN 60068-2-64:2008 ( broadband random vibration ), LST EN 60068-2-27:2009 (Shock).

Keywords: Exciters, vibrations

Keywords: f

Blein device

Description: Blein device

Technical specification: A distance of sample height 15 ± 1 mm; The measuring chamber Ø 12,7 ±0,1 mm; Principle of operation - manual

Usage area: Material fineness setting

Keywords: Materials Research

Wardrobe for drying SNOL58/350

Description: Wardrobe for drying SNOL58/350

Technical specification: from 30°C till 350°C

Usage area: Material drying

Keywords: Materials Research

Drying oven SNOL 200/200

Description: Drying oven SNOL 200/200

Technical specification: from 30°C till 350°C

Usage area: Material drying

Keywords: Materials Research

Kjeldahl distillation unit, "UKD 130"

Description: Kjeldahl distillation unit, "UKD 130"

Technical specification: Setting limits - up to 1 mg Kjeldahl nitrogen in the test sample. The best results are obtained when the sample is 10-15 mg of ammonium nitrogen.

Usage area: Determination of the nitrogen content in aqueous solutions based on Kjeldahl method.

Keywords: The nitrogen content.

Small tabletop muffle "Thermolyne 1400 Furnace"

Description: Small tabletop muffle "Thermolyne 1400 Furnace"

Technical specification: Operating temperature range - 0-1100 ° C. The interior of the high-temperature-resistant ceramics.

Usage area: Heating of the sample (0 – 1100 ºC).

Keywords: Heating of the sample.

Analytical electronic balance, "Ohaus Analytical Plus"

Description: Analytical electronic balance, "Ohaus Analytical Plus"

Technical specification: Maximum sample weight - 110 g. Scaling value - 0.1mg.

Usage area: Sample mass measurements (0 - 110g, d = 0.0001g).

Keywords: Analytical balance

Zeta Potential and Submicron Particle Size Analyzer Beckman Coulter DelsaNano C

Description: Zeta Potential and Submicron Particle Size Analyzer Beckman Coulter DelsaNano C

Technical specification: Concentration: 10 ppm - 40%; particle size: 0.6 nm - 7 µm, 0.6 nm - 30 µm (zeta potential); Zeta potential: -200 mV - 200 mV.

Usage area: Particle sizing, zeta potential

Keywords: Particle sizing, zeta potential

Centrifuge Hettich Universal 320 R

Description: Centrifuge Hettich Universal 320 R

Technical specification: Speed 0-9000 rpm, temp.range -20- 40 ºC.

Usage area: For phase separation by centrifugation

Keywords: Centrifugation, phase separation

ELPI ™ (Electrical Low Pressure Impactor). Enables measurement of real-time particle size distribution and concentration in the size range of 6nm - 10μm with 10Hz sampling rate

Description: ELPI ™ (Electrical Low Pressure Impactor). Enables measurement of real-time particle size distribution and concentration in the size range of 6nm - 10μm with 10Hz sampling rate

Technical specification: Particle size range - 0.006-10μm. Faction - 14. The sampling flow rate - 10 l/min.

Usage area: Real-time aerosol particle dispersion composition analysis, with the ability to collect particles of different fractions for further analysis (14 fractions, 0.006 - 10.0μm).

Keywords: Aerosol particles, dispersion composition.

Nanoscan SMPS nanoparticle sizer 3910. Nanoparticle number concentration meter

Description: Nanoscan SMPS nanoparticle sizer 3910. Nanoparticle number concentration meter

Technical specification: Operating modes: scanning - particle distribution across the measurement range (60 s); The desired particle size monitoring (1s). Measuring range - 10 to 420nm. Particle concentration - 100 to 1,000,000 particles/cm3.

Usage area: Aerosol nanoparticle dispersion composition in real-time (10-420 nm).

Keywords: Aerosol nanoparticles

PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Description: PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Technical specification: Aerosol concentration measurement range - 0.001 to 400.0mg/m3. Particle size range for maximum accuracy - 0.1 to 10μm.

Usage area: Measurements of personal exposure to aerosol particles in the workplace.

Keywords: Aerosol particles

Humidity measuring instrument Moisture Master Pro

Description: Humidity measuring instrument Moisture Master Pro

Technical specification: Solid material moisture meter from 0 till 99%

Usage area: Materials Research

Keywords: Materials Research

Mobile dust extractor CLEANTEX CTL 26E

Description: Mobile dust extractor CLEANTEX CTL 26E

Technical specification: Power consumption 350-1200 W Airflow max. 3900 l/min Max. vacuum 24000 Pa

Usage area: For dust with limit values > 1 mg/m³ Flexible and clean in the workshop and on-site thanks to compact design Integral automatic electronic switch-on/shut-off for extraction from electric power tools Suitable for both wet and dry extraction

Keywords: Cleaner, dust

surfase temperature meter

Description: surfase temperature meter

Technical specification: 0.....40 C

Usage area: Surfase temperature

Keywords: temperature

Hidraulic press GRM-1

Description: Hidraulic press GRM-1

Technical specification: from 0 till 500 kN

Usage area: Concrete crushing and bend samples

Keywords: Concrete samples

Electric drill for columns REMS Picus Basic Pack

Description: Electric drill for columns REMS Picus Basic Pack

Technical specification: Ø50; Ø100; Ø150

Usage area: Concrete drilling for cylindrical test objects

Keywords: Concrete, drilling

Compression press IP-1000

Description: Compression press IP-1000

Technical specification: from 0 till 1000 kN

Usage area: Samples of concrete crushing

Keywords: Concrete samples

The test machine Toni Technik Nr.132/389

Description: The test machine Toni Technik Nr.132/389

Technical specification: from 0 till 600 kN

Usage area: Samples of concrete crushing

Keywords: Concrete samples

impedance analyzer

Description: impedance analyzer

Technical specification: frequency 3 µHz-3 MHz. 2-3 elektrode system. Phase: 0,001 °. Sample diameter 16 mm. 2 measurement congurations: "in-plane"and "through-plane".

Usage area: investigations of electrical properties of dielectric films, testing of fuel cells

Keywords: investigations of electrical properties of dielectric films, testing of fuel cells

The portable measurement and data processing unit Pulse 3560

Description: The portable measurement and data processing unit Pulse 3560

Technical specification: Frequency range: 0 to 25.6 kHz; Input voltage: 7 ranges from 7,071 mVpeak to 7,071 Vpeak in 10 dB steps.

Usage area: Noise and vibration measurements and analysis; Sound intensity measurements.

Keywords: Measurements gauges, vibration, noise,

Sound pressure level meter Investigator 2260. The basic system.

Description: Sound pressure level meter Investigator 2260. The basic system.

Technical specification: Frequency range: 5 - 20kHz; Nominal sensitivity -26 dB ± 1.5 dB; Measurement range 24 ... 150 dB.

Usage area: Noise measurements and analysis; Sound intensity measurements

Keywords: Measurements, gauges, noise

The data collection and vibration measuring device VIBROTEST 60

Description: The data collection and vibration measuring device VIBROTEST 60

Technical specification: Frequency range: 1 - 20kHz; Speed ​​range 30 ... 600000 rpm; Speed ​​measurement accuracy 0,01 Hz (1 rpm); The measurement range of the transducer AS-065 1500m/s2 ; The measurement accuracy <2%.

Usage area: Vibration measurement and analysis, balancing, speed measurements.

Keywords: Vibration, balancing, analysis

Stand of liquid and solid fuel ash analysis. Analysis is performed acording EU standard

Description: Stand of liquid and solid fuel ash analysis. Analysis is performed acording EU standard

Technical specification: Burning temperature up to 1100 C, capacity of the chamber 160x250x100 mm

Usage area: The analysis of the ash content in hard fuel

Keywords: Fuel , biofuel, determination of ash content

Stand of oil compostion analysis (for study process)

Description: Stand of oil compostion analysis (for study process)

Usage area: Stand sold for Chem tech. dept.

Keywords: f

Wearable device for monitoring human physical activity parameters MinimaxX (model v2.OPCB)

Description: Wearable device for monitoring human physical activity parameters MinimaxX (model v2.OPCB)

Technical specification: Wearable elite sports computer for monitoring human physical activity parameters. 3 axis 100 Hz accelerometers (linear motion, impact forces, jump height, airtime, acceleration, deceleration and more); 3 axis 100 Hz gyroscopes (angular motion, rotation); 3 axis 30 Hz Magnetometers (direction, orientation); GPS 1-5 Hz; Heart rate sensor for Polar type HR monitors; Size 50x18x88 mm 5 hours battery life; waterproof to 1 m; mass 67 g; wireless communication with PC (Logan Plus Analysis Software for measurements and data processing, hundreds of metres range) for up to 100 units technology

Usage area: Monitoring human physical activity parameters (single person or team up to 100 athletes). Displays (transmits to PC) athlete`s position, instantaneous speed and direction, impact loading, heart rate, efforts at different speed bands, provides the magnitude of impact force, the direction of impact, whether the athlete was brought to the ground, measures start reaction time, technique deterioration and stride or stroke rate

Keywords: Physical activity, monitoring

The shock device

Description: The shock device

Technical specification: Pulse parameter: (Load 5 kg) Pulse duration 1,5 ....20ms; Pulse amplitude 100 m/s2...4000*m/s2; (Load 50 kg) Pulse duration 2 ....18 ms; Pulse amplitude 100m/s2…1600*m/s2; (Load 100 kg) Pulse duration 2 ....15 ms; Pulse amplitude 100m/s2…500*m/s2.

Usage area: Environmental impact test in accordance with LST EN 60068-2-27: 2009 (Shock)

Keywords: Shock , tests

Device for roughness measurement of mechanical surfaces

Description: Device for roughness measurement of mechanical surfaces

Technical specification: Measurement accuracy: 1.Ra: 0.03μm~6.3μm/1μ~250μ. 2.Rz: 0.2μm~50.0μm/8μ~999μ. 3.Ry/R max: 0.2μm~25μm/8μ~999μ. •Resolution: 0.01μm/1μ. •Measurement range 0.8mm/0.30”; ANSI 2RC Filter

Usage area: Surface roughness measurements

Keywords: Surface roughness measurements

Langmuir-Blodgett trough and control system

Description: Langmuir-Blodgett trough and control system

Technical specification: Surface area – 400 cm2 Working area – 318 cm2 Volume – 1000-1050 cm3 Surface pressure sensor – Wilhelmi plate (error 0,1 mN/m)

Usage area: Langmuir-Blodgett trough is used to deposit single or multiple monolayers on a solid substrate.

Keywords: Langmuir-Blodgett trough, thin layers

FT-IR spectrometry system

Description: FT-IR spectrometry system

Technical specification: System consists of Vertex70 spectrometer (Bruker), UV light source Omnicure S2000, Golden Gate Mk II ATR Accessory with Heated Diamond Top-plate, horizontal QuickLock transmittance accessory, standard spectral range covers 8,000 to 350cm-1, DTGS and MCT liquid nitrogen cooled detectors, rapid scan option for more than 68 spectra/sec at a spectral resolution of 16cm-1. Peaction monitoring option.

Usage area: Investigation of photopolymerisation and thermalpolymerisation, investigation of photodegradation processes in organic materials, investigation of organic materials during apllication of heat.

Keywords: Infrared absorbtion spectra, photopolymerisation, thermal polymerisation, photostability

Universal surface analysis system for X-Ray photoelectron spectroscopy, ion scatering spectroscopy, reflection electron energy loss spectroscopy, and angle Resolved XPS (ARXPS)

Description: Universal surface analysis system for X-Ray photoelectron spectroscopy, ion scatering spectroscopy, reflection electron energy loss spectroscopy, and angle Resolved XPS (ARXPS)

Technical specification: Monochromatised X-Ray sorce (Al anaode). Elements detection limits from 0.1% to 5%. Lens-defined area lateral resolution from 20 µm to 900 µm. High-resolution parallel imaging spectra from areas down to ~ 5 µm. Elements detection limits from 0.1% to 5%. Sample heating up to 1000 K, sample cooling down to 77 K; vacuum better then 5*10-10 mB.

Usage area: Quantitative and qualitative surface analysis using X-Ray photoelectron spectroscopy, ion scattering spectroscopy, reflection electron energy loss spectroscopy, angle Resolved XPS (ARXPS) with Ar ion surface eching/cleaning possibility

Keywords: X-Ray photoelectron spectroscopy, ion scatering spectroscopy, electron spectroscopy, reflection electron energy loss spectroscopy, Angle Resolved XPS (ARXPS)

Portable mobile system Noraxon for measurement of biomechanical parameters. Amplifier with Bluetooth interface with PC where software for data acquisition and processing is installed and a set of transducers

Description: Portable mobile system Noraxon for measurement of biomechanical parameters. Amplifier with Bluetooth interface with PC where software for data acquisition and processing is installed and a set of transducers

Technical specification: 4 channels amplifier Myo Trace 400 with Bluetooth interface with PC; measurements and data processing software MyoResearch XP Clinical; transducers: self-adhesive EMG (muscles electrical activity), goniometers (mechanical 1-D (±160o) and electrical 2-D (±160o), 1-D accelerometer (2g), inclinometer, spot force sensors (5 and 110 N), hand dynamometer (< 600 N).

Usage area: Measurements of human biomechanical parameters during research of steady state or different physical activities (gait analysis, work, sports or casual activities etc.)

Keywords: Biomechanics, amplifier, sensor, EMG, goniometer, accelerometer, inclinometer, dynamometer

General Physics Laboratory - 247

Description: Physics laboratory works are carried out for deeper knowledge of the basic laws of physics: performing them students learn to work with measurement devices and are introduced to measurement methods; they learn to depict methods as graphs and evaluate the reliability of the experimental results. Physics 2 (optics and atomic physics) laboratory works.

Technical specification: 1. Determination of light wavelength by Fresnel biprism 2. The diffraction gratings 3. Diffraction of laser light 4. Verification of Malus‘s law and determination of Brewster‘s angle 5. Investigation of polarization light rotation 6. Investigation of elliptical polarized light 7. Investigation of light dispersion in prism 8. Investigation of refractive index of solutions by refractometer 9. Stefan and Boltzmann law verification 10. Investigation of thermal radiation 11. Investigation of photoelectric effect 12. Investigation of internal photoeffect of semiconductor photoresistor 13. Temperature dependence of semiconductor conductivity 14. Qualitative spectral analysis 15. Franck-Hertz experiment 16. Determination of Planck constant by excitation voltage of laser 17. Investigation of attenuation of g rays in material 18. Investigation of surface tension dependence on liquid concentration 19. Coefficient of linear thermal expansion of solid body determination 20. Investigation of metal resistance dependence on the temperature 21. Determination of conductor specific resistivity 22. Investigation of electrostatic field 23. Investigation of phenomenon of thermionic emission

Usage area: General Physics Laboratory works are carried out by the first and second year students at KTU.

Keywords: "Optics, semiconductors, radioactivity (gama radiation), photoelectric effect and atomic physics

General Physics Laboratory - 263

Description: Physics laboratory works are carried out for deeper knowledge of the basic laws of physics: performing those students learn to work with measurement devices and are introduced to measurement methods; they learn to depict methods as graphs and evaluate the reliability of the experimental results. Physics 1 (mechanics and electromagnetism) laboratory works. Physics 2 (optics and atomic physics) laboratory works.

Technical specification: Physics I LIST OF LABORATORY WORKS IN 263 LABORATORY 1. Evaluation of direct and non-direct measurement errors 2. Measurement of electrical dimensions and measurement errors 3. Atwood‘s machine 4. Determination of free fall acceleration of solid body 5. Investigation of rotational motion of solid body 6. Investigation of Maxwell pendulum oscillation 7. Investigation of moment of inertia by rotational pendulum 8. Investigation of oscillation of string 9. Determination of sound speed in air by wave interference method 10. Investigation of thermal expansion coefficient of solid body 11. Ratio of molar heat capacities (Cp/Cv) of air determination 12. Investigation of surface tension dependence on liquid concentration 13. Determination of entropy variation 14. Investigation of electrostatic field 15. Investigation of dielectric electrical properties 16. Investigation of metal resistance dependence on the temperature 17. Investigation of thermionic emission phenomenon 18. Determination of magnetic field of the Earth 19. Investigation of magnetic field, created by wire 20. Determination of resistance by Vinston bridge 21. Investigation of ferromagnetics (Hysteresis loop) Physics II LIST OF LABORATORY WORKS IN 263 LABORATORY 1. Determination of light wavelength by Fresnel biprism 2. The diffraction gratings 3. Diffraction of laser light 4. Verification of Malus‘s law and determination of Brewster‘s angle 5. Investigation of polarization light rotation 6. Investigation of refractive index of solutions by refractometer 7. Stefan and Boltzmann law verification 8. Investigation of thermal radiation 9. Investigation of photoelectric effect 10. Investigation of internal photoeffect of semiconductor photoresistor 11. Qualitative spectral analysis 12. Franck-Hertz experiment 13. Investigation of attenuation of g rays in material

Usage area: General Physics Laboratory works are carried out by the first and second year students at KTU.

Keywords: Mechanics, electrodynamics, electromagnetism, and molecular physics. Optics, semiconductors, radioactivity (gama radiation), photoelectric effect and atomic physics

Laboratory of Vacuum science and Technique - 230

Technical specification: Laboratory works of electrodynamics 1. Investigation of the optical effects of electromagnetic waves 2. Application of electromagnetic wave diffraction for the investigation of crystal structure testing 3. Measurement of the semiconductor relative permittivity using “cylindrical inhomogeneity” in waveguide line 4. Measurement of the optical parameters and permittivity using Michelson interferometer 5. Investigation of the rectangular waveguide line and its working modes 6. Application of the waveguide line short-circuit and empty-mode methods for materials characterization

Keywords: Waveguide line, relative permittivity, electromagnetic waves.

Laboratory of Physical Technologies and Microtechnology

Description: Laboratory work objectives: to acquire modern microtechnology, to obtain practice in use of technological equipment and measurement of formed microstructures electrophysical characteristics.

Technical specification: 1. Cleaning and inspection of silicon wafer surface. 2. Study of silicon isothermal oxidation in diffusion furnace. 3. Study of silicon isochronous oxidation in diffusion furnace. 4. Formation of microstructures by means of optical contact lithography.

Usage area: For students of Applied Physics bachelor study program and Materials and Nanotechnologies bachelor study program in Faculty of Mathematics and Natural Sciences.

Keywords: silicon, silicon dioxide, diffusion furnace, oxidation, photolithography, etching.

General Physics Laboratory - 261

Description: Physics laboratory works are carried out for deeper knowledge of the basic laws of physics: performing those students learn to work with measurement devices and are introduced to measurement methods; they learn to depict methods as graphs and evaluate the reliability of the experimental results. Physics 1 (mechanics and electromagnetism) laboratory works.

Technical specification: LIST OF LABORATORY WORKS IN 261 LABORATORY 1. Evaluation of direct and non-direct measurement errors 2. Measurement of electrical dimensions and measurement errors 3. Atwood‘s machine 4. Investigation of rotational motion of solid body 5. Investigation of Maxwell pendulum oscillation 6. Investigation of moment of inertia by rotational pendulum 7. Investigation of oscillation of string 8. Investigation of thermal expansion coefficient of solid body 9. Ratio of molar heat capacities (Cp/Cv) of air determination 10. Investigation of surface tension dependence on liquid concentration 11. Determination of entropy variation 12. Investigation of electrostatic field 13. Investigation of dielectric electrical properties 14. Investigation of metal resistance dependence on the temperature 15. Investigation of thermionic emission phenomenon 16. Determination of magnetic field of the Earth 17. Investigation of surface tension dependence on the temperature 18. Determination of sound speed in air 19. Diffraction of ultrasound waves 20. Investigation of attenuated oscillations 21. Investigation of magnetic field, created by wire 22. Hysteresis loop 23. Determination of free fall acceleration of solid body

Keywords: Mechanics, electrodynamics, electromagnetism, and molecular physics

General Physics Laboratory - 225

Description: Physics laboratory works are carried out for deeper knowledge of the basic laws of physics: performing those students learn to work with measurement devices and are introduced to measurement methods; they learn to depict methods as graphs and evaluate the reliability of the experimental results. Physics 1 (mechanics and electromagnetism) laboratory works.

Technical specification: 1. Evaluation of direct and non-direct measurement errors 2. Measurement of electrical dimensions and measurement errors 3. Determination of free fall acceleration constant 4. Investigation of transmittance of optical glass 5. Investigation of rotational dynamics of solid body 6. Determination of adiabatic constant 7. Magnetic force measurement 8. Investigation of conservation law of rotational motion 9. Measurement of the sound speed in the rod 10. Investigation of magnetic field created by wire 11. Investigation of polarization of segnetoelectrics 12. Investigation of oscillation of physical pendulum 13. Investigation of oscillation of string 14. Investigation of oscillation of string 15. Investigation of electrostatic field 16. Investigation of dielectric electrical properties 17. Investigation of metal resistance dependence on the temperature 18. Evaluation of conservation law of the charge 19. Investigation of rotational motion 20. Ratio of molar heat capacities (Cp/Cv) of air determination 21. Atwood‘s machine

Usage area: General Physics Laboratory works are carried out by the first and second year students at KTU.

Keywords: Mechanics, electrodynamics, electromagnetism, and molecular physics.

General Physics Laboratory - 235

Description: Physics laboratory works are carried out for deeper knowledge of the basic laws of physics: performing them students learn to work with measurement devices and are introduced to measurement methods; they learn to depict methods as graphs and evaluate the reliability of the experimental results. Physics 2 (optics and atomic physics) laboratory works.

Technical specification: 1. Determination of light wavelength by Fresnel biprism 2. The diffraction gratings 3. Diffraction of laser light 4. Verification of Malus‘s law and determination of Brewster‘s angle 5. Investigation of polarization light rotation 6. Investigation of elliptical polarized light 7. Investigation of light dispersion in prism 8. Investigation of refractive index of solutions by refractometer 9. Investigation of thermal radiation 10. Stefan and Boltzmann law verification 11. Investigation of photoelectric effect 12. Einstein‘s law verification 13. Temperature dependence of semiconductor conductivity 14. Determination of Plank constant by adsorption spectra 15. Qualitative optical spectroscopy 16. Investigation of attenuation of g rays in material

Usage area: General Physics Laboratory works are carried out by the first and second year students at KTU.

Keywords: Optics, semiconductors, radioactivity (gama radiation), photoelectric effect and atomic physics.

Laboratory works of material physics - 225

Description: Laboratory works of material physics are carried out by the first year students of KTU Mathematics and natural sciences faculty, studying the module "Materials Physics", as well as fourth-year students of Computer science faculty who have chosen the module "Introduction to Materials Science".

Technical specification: 1. Investigation of transmittance of optical glass 2. Measurement of the sound speed in the rod 3. Investigation of polarization of segnetoelectrics 4. Determination of conductors specific resistivity 5. Investigation of dielectric electrical properties 6. Investigation of metal resistance dependence on the temperature 7. Investigation of refractive index of solutions by refractometer 8. Current - voltage relation forPEM characteristics 9. Coefficient of linear thermal expansion of solid body determination 10. Evaluation of liquid density 11. Investigation of thermionic emission 12. Determination of band gap of germanium 13. Investigation of semiconductor diode and transistor characteristics 14. Investigation of magnetic field created by wire

Usage area: Laboratory works of material physics are carried out by the first and fourth year KTU Mathematics and natural sciences faculty students, studying the module "Materials Physics" or "Introduction to Materials Science".

Keywords: Mechanics, electricity, optics, atomic physics, materials and nanotechnology, physics.

General Physics Laboratory - 240

Description: Physics laboratory works are carried out for deeper knowledge of the basic laws of physics: performing those students learn to work with measurement devices and are introduced to measurement methods; they learn to depict methods as graphs and evaluate the reliability of the experimental results. Physics 1 (mechanics and electromagnetism) laboratory works. Physics 2 (optics and atomic physics) laboratory works.

Technical specification: Physics I LIST OF LABORATORY WORKS: 1. Evaluation of direct and non-direct measurement errors 2. Measurement of electrical dimensions and measurement errors 3. Atwood‘s machine 4. Investigation of rotational motion of solid body 5. Investigation of Maxwell pendulum oscillation 6. Investigation of oscillation of physical pendulum 7. Investigation of oscillation of rotational pendulum 8. Investigation of oscillation of spring 9. Investigation of oscillation of string 10. Ratio of molar heat capacities (Cp/Cv) of air determination 11. Investigation of surface tension dependence on liquid concentration 12. Investigation of dielectric electrical properties 13. Investigation of metal resistance dependence on the temperature 14. Determination of magnetic field of the Earth 15. The electron motion in magnetron 16. Evaluation of conservation law of the charge 17. Magnetic force measurement 18. Evaluation of the main law of rotational motion of solid body 19. Stefan and Boltzmann law verification 20. Cp/Cv determination by ultrasound 21. Investigation of magnetic field created by circular conductor 22. Investigation of polarization of segnetoelectrics Physics II LIST OF LABORATORY WORKS: 1. Determination of light wavelength by Fresnel biprism 2. The diffraction gratings 3. Diffraction of laser light 4. Verification of Malus‘s law and determination of Brewster‘s angle 5. Investigation of polarization light rotation 6. Investigation of elliptical polarized light 7. Investigation of light dispersion in prism 8. Investigation of refractive index of solutions by refractometer 9. Investigation of thermal radiation 10. Stefan and Boltzmann law verification 11. Investigation of photoelectric effect 12. Einstein‘s law verification 13. Investigation of internal photoeffect of semiconductor photoresistor 14. Temperature dependence of semiconductor conductivity 15. Investigation of tunnel effect of p-n 16. Qualitative spectral analysis 17. Franck-Hertz experiment 18. Investigation of attenuation of g rays in material

Usage area: General Physics Laboratory works are carried out by the first and second year students at KTU.

Keywords: Mechanics, electrodynamics, electromagnetism, and molecular physics. Optics, semiconductors, radioactivity ( radiation), photoelectric effect and atomic physics.

Device for multiplication of holograms

Description: Device for multiplication of holograms

Technical specification: Multiplication of optical security marks on silicone paper and multilayer polymeric film. Formation temperature in the range of 70-180 ºC. The width of the tape 106 mm. The length of the tape 1000 m.

Usage area: Fabrication of optical document security intellectual property measures with micro-diffractive elements.

Keywords: Document security

Laboratory of Vacuum science and Technique - 252

Description: Laboratory of Physical Technologies Works are designed for deeper understanding of physical phenomena in various sensors, for improvement of skills in presentation and estimation of received data. The equipment for changing the magnetic field, temperature, electrical current, voltage, displacement values are used in these works. Measurements are carried out using ammeters, voltmeters, digital storage oscilloscope, thermocouple thermometers.

Technical specification: Basics of vaccum physics and technologies 1. Measuring of air viscosity coefficient for low vacuum case. 2. Measuring of air heat conductivity coefficient for low vacuum case. 3. Measuring of positive displacement vacuum pump pumping speed. 4. Measurement of low pressures. Physical principles of sensors 1. Investigation of the magnetic field sensor. 2. Investigation of Peltier phenomenon. 3. Investigation of the resistance temperature detectors. 4. The use of the optical interferometric sensor for displacement and vibrations measurements.

Usage area: Basics of vaccum physics and technologies and Physical principles of sensors laboratory works are performed by students of faculty of mathematics and natural sciences during postgraduate programs in Applied Physics and Materials Science. Extended study properties of gases at low pressures and modern vacuum practice, low and high vacuum realizing technology by different vacuum pumps are on investigation. Vacuum measurements by thermal and electrical methods are used. Laboratories are aimed for bachelor studies in physics and material science.

Keywords: The physical basis and technology of vacuum, vacuum pumps, measurement of vacuum, phenomena in low pressure gases, sensor, sensor of the physical value, the sensor characteristics, physical principle

Hydrothermal processing of materials under high pressure system

Description: Hydrothermal processing of materials under high pressure system

Technical specification: Multiple controlled system by PC which consists of stirred and non-stirred autoclaves. Flexible process control unit to handle up to six individual autoclaves with PID temperature control and data logging for all relevant process data (pressure, temperature, time, rate of rotation and etc.). Exchangeable cylinders of pressure vessels in stirred and non-stirred autoclaves with different volumes. No welded parts (valves, adapters, cylinder and etc.) in the autoclaves, all parts screwed in, removable and exchangeable.

Usage area: Hydrothermal synthesis

Keywords: Stirred and non-stirred autoclaves

Thermogravimetric Analyzer Linseis STA PT1600 coupled with mass spectrometer GSD320 Linseis/Pheiffer Vacuum

Description: Thermogravimetric Analyzer Linseis STA PT1600 coupled with mass spectrometer GSD320 Linseis/Pheiffer Vacuum

Technical specification: STA PT1600 specifications: temperature interval - -40 - 1500 °C; accuracy - ± 1 %; max. sample weight up to 5 g. Quadrupole mass spectrometer intervals - 1-100 amu; 1-200 amu; 1-300 amu.The synhronization of experiment beginning by STA-MS as well as the corelation during the whole experiment is guaranteed and controlled.

Usage area: The evaluation of physical and chemical properties of the sample (mass changes, decomposition, crystallization or melting temperature, specific heat and other thermal conversions) while the substance is subjected to a controlled temperature program in a specified atmosphere; the evaluation of evaporated gas from a sample.

Keywords: Simultaneous thermal analysis, evaporated gas analysis

Beer making (brewing) unit

Description: Beer making (brewing) unit

Technical specification: Two-vessel brewhouse with whirlpool; Two cylindroconical fermenting tanks and one open fermenter; It is possible to produce very small quantity of beverage (only 30 liters, in some cases even less). Laboratory equipment allows you to work using methods similar to specific large industry methods. Technological processes are automated, easily operated and programmed.

Usage area: For studies, research work in the field of brewing technology (fermentation), for technological investigations or development of new fermentable beverages.

Keywords: Beer making technology

Equipment for composition and emulsions formation

Description: Equipment for composition and emulsions formation

Technical specification: Kilia vacuum bowl cutter 30L VK 4000 express. Advantage of the deep bowl form is the low minimum capacity of 20 %, which is important for recipes with a small production volume The maximum batch size depends on each product, but should usually not be over 80%. Knife shaft drive frequency converter controlled (AC-drive) with 6 fixed programmed speeds, 4 forward (50, 100, 2500, 5000 rpm), 2 reverse (50, 100 rpm). Variable bowl drive (7-20 rpm). Homogenizer-coloidal mill SG-1325-2B. Capacity 100 kg/h, 15 l. Meat mixer Fama Fic 30M. Capacity 30 kg. 47 rpm.

Usage area: Meat and fish technology

Keywords: Meat and fish technology

cooling stand TE6/EV and TE6A/EV

Description: cooling stand TE6/EV and TE6A/EV

Technical specification: Cooling water 0-100 l/h, heat element 60 W

Usage area: heat transfer service unit, linear heat conduction

Keywords: cooling

Pressure losses pilot plant DPA/EV

Description: Pressure losses pilot plant DPA/EV

Technical specification: Centriugal pump 0-10 m3/h. Manometer sygnal 4-20 mA

Usage area: Investigation of different fluid flow hydrodynamic structure

Keywords: fluid hydrodynamics

Mettler Toledo T70 potentiometer.

Description: Mettler Toledo T70 potentiometer.

Technical specification: pH measurement (0-14) selective measurement of ions Cu2 ; Cd2 ; Ca2 ; F-; Cl-

Usage area: titration,measurement of different ions concetration

Keywords: titration,measurement of ions concetration

"Dekati ®"double diluter setup for combustion measurements

Description: "Dekati ®"double diluter setup for combustion measurements

Technical specification: The dilution ratio - 1:49. Dilution air pressure - 2 bar. Operating temperature - 0-450 º C.

Usage area: The dilution device for sampling from concentrated sources.

Keywords: Diluter

HPLC system with UV/VIS and DAD

Description: HPLC system with UV/VIS and DAD

Technical specification: Mamual injection, RIT detector, 5 independent channels with up to four solvents in a single run, the gradient can be made under high and low pressure.

Usage area: Chromatographic analysis

Keywords: Chromatography

Liophylisator SPI Industries Sentry 2.0

Description: Liophylisator SPI Industries Sentry 2.0

Technical specification: Temp.range -50 - 10 ºC, vacuum range: 20-2000 mTorr.

Usage area: Freez-drying of materials

Keywords: Freez-drying

Thermogravimeter

Description: Thermogravimeter

Technical specification: TA Instruments Q50. Max sample weight 1g, Temperature range - ambient to 1000oC, heating rate 0.1- 100oC/min

Usage area: Investigation of thermostability of organic materials

Keywords: Thermogravimetry

HPLC system

Description: HPLC system

Technical specification: Automatic injection, diode fluorescecnce detector, 2 independent channels with up to four solvents in a single run, column temperature control up to 40°C.

Usage area: Chromatographic analysis

Keywords: Chromatography

DRON-6 powder X-ray diffractometer

Description: DRON-6 powder X-ray diffractometer

Technical specification: powderX-ray diffractometer with Bragg-Brentano geometry using Ni-filtered CuKα radiation, operating at a voltage of 30 kV and an emission current of 24 mA. The step-scan covered the angular range 5–60 (2θ) in steps of 2θ = 0.02.

Usage area: powder X-ray analysis

Keywords: X-ray analysis

Microwave reactor Anton Paar GmbH - Monowave 300

Description: Microwave reactor Anton Paar GmbH - Monowave 300

Technical specification: 850W. Max. Temp. 300°C, operating pressure 30 bar, max. pressure 200 bar. max. mixing speed 1200 rpm. Three SiC vessels, filling volume from 0.5 to 20 ml.

Usage area: Microvawe synthesis

Keywords: Microvawe synthesis

Thermomechanical analyzator and dielectric spectrometer

Description: Thermomechanical analyzator and dielectric spectrometer

Technical specification: MCR302 rheometer (Anton Paar). Heating range of convection oven is from -150 to 450oC. Plate-Plate geometries of 8 and 15mm available. Universal Extensional Fixture for soft films tension experiments. Dielectro-reological device, UV curing system.

Usage area: Rheological tests in rotational and oscillatory modes are possible. DMTA analysis of soft films, fibers, polymer melts. UV curing experiments. Detection of phase transitions by dielectric spectroscopy.

Keywords: dynamic mechanical thermal analysis, dielctric spectroscopy, UV curing

Air handling unit with direct-driven supply air and extract air fans.

Description:

Air handling unit with direct-driven supply air and extract air fans.

Technical specification:

Air handling unit with direct-driven supply air and extract air fans.

Usage area: Air handling unit with direct-driven supply air and extract air fans.

Keywords: Pressure, temperature

Electroacustic spectrometer DT-300

Description: Electroacustic spectrometer DT-300

Technical specification: Sample volume 2-100 ml, concentration 0.1-50%; particle size <100 micrometers

Usage area: For determination of zeta potential of particles in dispersions

Keywords: Zeta potential, electroacustic method

Differential scanning calorimeter Perkin Elmer DSC8500

Description: Differential scanning calorimeter Perkin Elmer DSC8500

Technical specification: Temp.range -100 - +750 ºC, heating rate 0.1-750 ºC/min.

Usage area: For DSC measurements, for investigations of materials phase and physical transitions

Keywords: Differential scanning calorimetry

Gelchromatografas Malvern Viscotek 270 Dual Detector

Description: Gelchromatografas Malvern Viscotek 270 Dual Detector

Technical specification: Refractive index and light scattering detectors, solvent DMSO, molecular weight range: 10000-4000000.

Usage area: For determination of molecular weight and polidispersity of biopolymers

Keywords: Gelchromatography, molecular weight

Twin screw extruder KrausMaffei Berstorf GmbH ZE25Rx40D-UTXmi

Description: Twin screw extruder KrausMaffei Berstorf GmbH ZE25Rx40D-UTXmi

Technical specification: Motor power: 26 kW; Throughput rate: 10kg/h; Speed screw (max): 1200 rpm; Number og heatable barrel housing: 7.

Usage area: Reactive extrusion of biopolymers

Keywords: Reactive extrusion

Polymer characterization system - molecular sieve chromatograh

Description: Polymer characterization system - molecular sieve chromatograh

Technical specification: Elution - 0,05-2 ml/min, molecular mass interval - 100-4×106 D, detection ( UV detector 200-400 nm, RI detector,low and high angle light scattering detector), eluent degassing system, UV spectra registration

Usage area: determination of polymers molecular masses (Mn, Mw, Mz and polidispersity

Keywords: Molecular sieve chromatograhy, MSC, gel permeation chromatography, GPC, molecular mass

Meat and fish thermal processing and cooling equipment

Description: Meat and fish thermal processing and cooling equipment

Technical specification: Universal Cooking and Smoking Installations BASTRAMAT, with Cooking, Roasting, Cooling, Drying, Climate maturing. Wood-chip smoke generation. Temperature range adjustable between +10° C and +100° C. Freezer Foinox BC 50 - 2A . All solid stainless steel construction . Operating temperature -+70° -18°, Pan capacity 5xGN1/1 - 5x(600x400). Output at +70°C +3°C-10,5 Kg. Output at +70°C -18°C-4,8Kg. Dimensions -750x700x850mmh

Usage area: Meat and fish thermal processing and cooling

Keywords: Meat and fish technology

Thermal eveporation system integrated into the glove-box

Description: Thermal eveporation system integrated into the glove-box

Technical specification: Mbraun glove-box, gas purification system, gas purification system for closed cycle cirulation, Rotary vane pump and turmolecular pumps, Sensor-Set: H2O-analyzer and O2-analyzer, 2 x thermal evaporators for metals, 2 x evaporators for organics (temperature range: 50°C up to 600°C, typical deposition rates: (10-3)… 5 nm/sec)

Usage area: Organic electronics device formation

Keywords: Thermal evaporation, organic semiconductor, OLED, organic electronics

Keywords: f

Diferential scanning calorimeter

Description: Diferential scanning calorimeter

Technical specification: TA Instruments Q2000, temp range -90oC to 550oC, sensitivity 0.2mW, modulated DSC mode, direct Cp measurement, PhotoDSC option

Usage area: Investigation of phase transitions of organic materials, investigation of kinetics of chemical reactions, investigation of photopolymerisation

Keywords: diferential scanning calorimetry

Hardness tester

Description: Hardness tester

Technical specification: Vickers, Rockwell, Brinell

Usage area: hardness measurement

Keywords: hardness measurement

Stand of solid fuel properties testing. Test are performed acording EU standard

Description: Stand of solid fuel properties testing. Test are performed acording EU standard

Technical specification: Calorific value of fuel. Samples of up to 1,5-2 g., accuracy of weighting 0,0001 g., samples up to 0,5 kg. Fuel moisture probe required

Usage area: Determination of calorific value of biofule and solid fuel

Keywords: Calorific value, fuel, moisture content, analysis

Optical scanner Nextengine for reverse engineering

Description: Optical scanner Nextengine for reverse engineering

Technical specification: Desktop optical 3D scanner for using in the rooms witg normal light conditions. Two regimes of scanning (Macro and Wide), scanning speed - 50000 points/sec., capture density up to 160K points / in (Macro) and 22.5K points / in (Wide); Field Size 5.1” x 3.8” (Macro) and 13.5” x 10.1” (Wide). High-precision rotary servo positioner, auto-incremented under scanner control (20 lb capacity), Universal part holder to adjust height, angle, and orientation of capture (10 lb capacity). Software to Scan, Align, Polish, and Fuse 3D Models. High-performance OpenGL 3D viewer; Scan inside SolidWorks; 2X scan speed, 4X raw point data, Large Object (23” x 17”) mode

Usage area: Scanning of 3D objects and creation of their surfasic and solid geometrical models for reverse engineering purposes and in other cases, when it is impossible or to difficult to obtain 3D computer geometric models of the objects, necessary for their visualization or for computational needs (for example, when modeling biomechanical systems)

Keywords: 3D scanning, computer geometric model, surfasic model, solid model

Scanning electron microscope

Description: Scanning electron microscope

Technical specification: Resolution in high vacuum up to 1.2 nm (30 kV, SE), up to 2.5 nm (30 kV, BSE) and up to 3 nm (1 kV, SE). Three available vacuum regimes: high vacuum (<6E-4 Pa), low vacuum (10-130 Pa), ESEM (10-4000 Pa). Conductive and isolating samples can be investigated.

Usage area: Sample vizualization

Keywords: Microscope, magnification, visualization, scanning electron microscope, SEM, electron microscope, secondary electrons, back scattered electrons, environmental SEM, ESEM, field emission gun, FEG

Stand of solid biofuel combustion research

Description: Stand of solid biofuel combustion research

Technical specification: 20 kW thermal power

Usage area: Burning of various granular fuels, usage of smoke analyzer to measure the consentrations of combustion products

Keywords: Solid fuel

Stand of thermo physical characteristics of liquid fuel

Description: Stand of thermo physical characteristics of liquid fuel

Technical specification: Liquid fuel vapour pressure (0-100 kPa, 18-90 oC); by Reid

Usage area: Determination of vapour pressure of light petroleum products

Keywords: Petroleum products, vapour pressure, Reid analysis

Stand of volatility charakteristics analysis

Description: Stand of volatility charakteristics analysis

Technical specification: Flash point; 18-100 oC

Usage area: Deetermination of the liquid fuel flash point

Keywords: Liquid fuel, flash point, analysis

Keywords: f

Stand of solid fuel combustion research

Description: Stand of solid fuel combustion research

Usage area: Only for the study process

Keywords: f

Keywords: f

Keywords: f

Combusion procuts components analyzer "MultilyzerNG``

Description: Combusion procuts components analyzer "MultilyzerNG``

Technical specification: CO consentration measurement range from 0-20000 ppm; SO2 measurement range from 0 to 2000 ppm; NO measurement range from 2000 ppm; 02 measurement range from 21 %

Usage area: Analysis of gas components in combustion products

Keywords: Smoke analysis, emission

3D printer

Description: 3D printer

Technical specification: models size 200x150x150 mm

Usage area: 3D printing

Keywords: 3D printing

Products of combustions gas components analyzer

Description: Products of combustions gas components analyzer

Technical specification: CO consentration measurement range from 0-2000 ppm; SO2 measurement range from 0 to 2000 ppm; NO measurement range from 2000 ppm; 02 measurement

Usage area: Analysis of gas components in combustion products, burning different fuels

Keywords: Smoke analysis, emission

X-ray fluorescence spectrometer TIGER S 8

Description: X-ray fluorescence spectrometer TIGER S 8

Technical specification: quantitative measurements of elements from beryllium to uraniumin in solids and liquids.

Usage area: Qualitative, quantitative and non-standard measurements of elements

Keywords: XRF

Rub fastness tester also called VESLIC IG/10/MOD (f. GIULIANI), Nr. 14279

Description: Rub fastness tester also called VESLIC IG/10/MOD (f. GIULIANI), Nr. 14279

Technical specification: Mass od finger 500 g, moving frequency of 40 cycles/min

Usage area: Appliance for testing the colourfastness to the wiping according to LST EN ISO 20344

Keywords: Colourfastness

GENERAL PURPOSE STRAIN VIEWER (Ref. S-18)

Description: GENERAL PURPOSE STRAIN VIEWER (Ref. S-18)

Technical specification: Field of view 260mm x 260mm, the total size of 445 x 280 x 280mm

Usage area: Products to determine the residual stresses in them

Keywords: quality control inspection of glass and plastics components

Stand of research for solid and liquid elemental composition

Description: Stand of research for solid and liquid elemental composition

Usage area: Only for the study process

Keywords: f

Mobile multi-channel electronic PC measurement unit for parallel, dynamic measurement data acquisition using a computer for the measurement of various mechanical parameters

Description: Mobile multi-channel electronic PC measurement unit for parallel, dynamic measurement data acquisition using a computer for the measurement of various mechanical parameters

Technical specification: Mobile portable computerized data acquisition system for measurements of mechanical parameters Spider Mobil 8 (HBM, Germany). 8 channel amplifier having wire interface with PC where data acquisition and processing software Catman32-E is installed; set of transducers: accelerometer (100 g, 0-250 Hz), tensile and compressive force (0-2 and 0-50 kN), displacement (0-2, 0-10 and 0-100 mm) and pressure (0-20, 0-100 and 0-200 bar). Precision class – not lower than 0,1%; Non-linearity – less than 0,05%.

Usage area: System may be used in cases when there is necessary to measure synchronically one or several mechanical parameters varying in time independently on the presence or absence of the electric supply (220 V)

Keywords: Measurements, amplifier, displacement, force, pressure, acceleration

Spectroscopic ellipsometer

Description: Spectroscopic ellipsometer

Technical specification: Spectroscopic ellipsometer covers UV-VIS-NIR spectral range. Available angles for measurements 12-90 deg with 0.01 deg resolution. Possibility to measure with focused beam 70x150 um. High resolution UV-VIS detector covers 190-900 nm range with 0.5 nm resolution, fast UV-VIS detector covers spectral range of 190-900 nm (1024 wavelengths), high resolution NIR detector 800-2000 nm with 3 nm resolution. Automated sample positioning with sample visualization via digital camera.

Usage area: Device is feasible to analyse optical constants (k(λ), n(λ)), thickness of thin isotropic and anisotropic transparent and non-transparent layers on isotropic and anisotropic transparent and non-transparent substrates. It can be also used for evaluations of periodical structures (scatterometry) and absorption kinetics in liquids.

Keywords: Spectroscopic ellipsometer, optical constants, refractive index, absorption coefficient, extinction, dispersion, dispersion curve, thickness determination, ellispometer

Three stage cascade impactor "Dekati® PM10" for determining gravimetric mass size distribution of particles

Description: Three stage cascade impactor "Dekati® PM10" for determining gravimetric mass size distribution of particles

Technical specification: Sample flow rate - 10 to 30 l/min. Three impactor stages for particles >10µm, 2.5µm and <1 µm.

Usage area: Aerosol particle dispersion composition analysis (0 - 1μm, 1 - 2.5μm, 2.5 - 10.0μm)

Keywords: Aerosol particles, dispersion composition.

Mass detector and liquid chromatography system

Description: Mass detector and liquid chromatography system

Technical specification: System consists of mass detector and HPLC system. Mass detector is single quadrupole, the mass range 0-3000m/z, ESI, APCI positive/negative ionization modes. The sample could be separated by high perfomance liquid chromatography using reverse phase column (BEH C18). Eliuent could be mixed using four solvents.

Usage area: Molecular weight detection of organic materials, purity estimation of the organic materials

Keywords: Molecular weight, chromatography, purity

Fermenters

Description: Fermenters

Technical specification: fermenters with working volume 35-500 ml and 300-1200 ml, infrared radiation is used to warm the culture; does not require cooling water. used to warm the culture;

Usage area: Fermentation and cultivation with bacteria, yeasts or fungi.

Keywords: Laboratory fermenters, microbiological culture, fermentation

Specimen cutter

Description: Specimen cutter

Technical specification: cutting disk - 140 mm, precision - 20 mkm

Usage area: metalogrphic analysis

Keywords: metalogrphic analysis

Chromatography System

Description: Chromatography System

Technical specification: Single Quadrupole, ionisation mode ESI and/or APCI, 15,000 u/sec fast scanning speed, ultra-fast analysis and separation

Usage area: Separation of organic compounds, mass detection

Keywords: chromatography, analytical, preparative, mass spectroscopy

Laser ellipsometer L115

Description: Laser ellipsometer L115

Technical specification: Length of the light wave used is 632.8 nm. Thickness of films possible for analysis is 0.001 - 1 µm. Uncertainty of thickness measurements is ±(0.5 – 1) nm. Accuracy of the refractive index measurements ±0.01.

Usage area: Measurements of refractive index and thickness of the dielectric and semiconducting thin films, semitransparent thin metal films (< 50 nm), polymeric thin films (e.g. photo resist).

Keywords: Laser ellipsometer, thin films, thickness, refraction index

Raman scattering spectrometer Renishaw in Via Spectrometer with accessories

Description: Raman scattering spectrometer Renishaw in Via Spectrometer with accessories

Technical specification: 532 nm, 45 mW semiconductor laser awaking 2400 lines / mm grating, termoelektriškai 1024 pixels cooled CCD Stokes lines measuring range from 100 cm-1 to 8000 cm-1 resolution - better than 1 cm -1. Leica confocal microscope with 3 lenses x20, x50 and x100.

Usage area: Raman scattering spectroscopy can be used for thin layers of powder and aqueous solutions of the investigation. In addition to information about the structure of materials, Raman spectroscopy can be used for some types of stress in thin layers of review. Software complex for Raman scattering spectra in the confocal micro-Raman optical system and luminescence measurements.

Keywords: Raman spectroscopy, materials research, identification

AFM Scanning probe microscopy system JPK NanoWizard 3

Description: Scanning probe microscopy system JPK NanoWizard 3

Technical specification: Operating modes: contact, intermittent contact or AC or tapping, non-contact, lateral force microscopy, Phase imaging; Force mapping; Quantitative imaging: images of the surface force curve, the force-distance spectroscopy of force-distance volumetric imaging mode, conductivity microscopy. Scanning field 100x100 μm height up to 15 μm.

Usage area: For measurements of the surface topography and the mechanical, electrical and magnetic properties in the air and fluids. For solids, polymers, biological samples and molecular characterization, nanomanipulation and nanolithography. Development and research of advanced new materials and thin films; control of technological processes at the nano-scale.

Keywords: AFM, atomic force microscopy, topography, morphology, nanolithography, nanotechnology, microscopy

Mask aligner and nanoimprint lithography

Description: Mask aligner and nanoimprint lithography

Technical specification: UV400: 350-450 nm; UV300: 280-350 nm; UV250: 240-260 nm. UV nanoimprint lithography, soft and hard contact, photomask size 102x102 and 127x127 mm.

Usage area: Mask alignement, UV exposure, nanoimprint lithography

Keywords: UV light, exposure, photolithography, optical lithography, nanoimprint lithography,

picoammeter / bias source

Description: picoammeter / bias source

Technical specification: bias /- 500V current 100 fA - 20 mA

Usage area: I-V measurements

Keywords: I-V measurements

Hydrothermal processing of materials under high pressure system

Description: Hydrothermal processing of materials under high pressure system

Technical specification: Max. temperature 350 oC Max.pressure 115 Bar.

Usage area: synthesi of materials under high pressure

Keywords: autoclave

Dilatometer L75H1600C

Description: Dilatometer L75H1600C

Technical specification: Temperature interval - from room temperature to 1600 °C; max. sample size - 50 mm; sample diameter - 7/12/20 mm; measuring range: lowest limit - 100 mm, upper limit - 5000 mm.

Usage area: The evaluation of changes in the sample dimensions (volume) while the substance is subjected to a controlled temperature program in a specified atmosphere. Typical materials under investigation are: composite materials, glass, polymers, ceramics, metals. Besides, powder can also be analysed.

Keywords: Dilatometry

XRD: X-ray diffractometer D8 Discover, Bruker

Description: X-ray diffractometer D8 Discover, Bruker

Technical specification: Specification: 2.2 kW X-ray tube with Cu anode. Parallel beam/ Bragg-Brentano geometry, Göbel mirror, 2xGe(022) crystal monochromator, rotary absorber, scintillation detector, 1D LynxEye detector, Eulerian cradle (X, Y, Z, Psi, Phi), Chi ir Xi motorized positioning table, X-ray reflectivity acessory, motorized slit accessory, PATHFINDER optics.

Usage area: Qualitative and quantitative analysis of chemical compounds; Ab initio-crystal structure of chemical compounds to identify and clarify; Material microstructure analysis (crystallite sizes, micro-stress, to determine the degree of crystallinity); X-ray diffraction measurements at a sliding angle of the focused (GID); Micro-Diffraction measurements; Small reflectometry and high resolution

Keywords: X-ray diffraction, structure, thin layers, analysis of chemical compounds

400 MHz NMR apparatus

Description: 400 MHz NMR apparatus

Technical specification: 9.4 Tesla permanent magnetic field . Room temperature homogeneity outdoor activities ( shim ) system for optimal magnetic field homogeneity needed for 1D , 2D and 3D experiments without rotation of the sample cuvette , and not less than 20 orthogonal gradient control. Not less than 2 equivalent and interchangeable frequency channels of communication with the full wide -frequency generation in each , and the minimum interval for each channel 6-430 MHz Complete digital phase and amplitude of the best generation of long-term stability to achieve Digital real- time compensation The required frequency change: steps < 0.01 Hz Phase change: steps < 0.01 Grad, with no more than 25 ns duration Radio frequency system output signal phase singalong / accuracy by changing the power attenuation ( monotony ): not more than / - 0.5 and 90 dB power conversion range. Individual and / or along the phase , frequency and / or amplitude of the event time : no more than 25 ns Impulse control temporal resolution of 12.5 ns or less Software -controlled variable temperature unit , the temperature change of 0.1 ° C increments  . Temperature changes at the interval narrower than the range - 150 to 180 ° . a) 5 mm head with actively shielded Z - gradient, can apply monitoring / irradiation of the NMR core range from 15N to 31P ( below) as well as 1H and 19F . Automatic selection, setting and atitaikymas all clusters interval from 15N to 31P . The ability to record the 1H and 19F spin interactions termination and vice versa . The minimum required parameters : Signal / Noise: 19F sensitivity ≥ 350:1 (TFT sample , the 1H interactions termination ) 31P sensitivity ≥ 150:1 ( TPP sample) 13C sensitivity ≥ 190:1 (ASTM test) 15N sensitivity ≥ 25:1 (90 % formamide sample) 1H sensitivity ≥ 450:1 (0.1 % EC sample , 200 Hz) Temperature changes at the interval narrower than from - 150oC to 150 oC . b ) CP / MAS head 15N - 31P , 1H ; Rotor size 4 mm, rotation frequency up to 15 kHz; shall be accompanied by a pneumatic module for precise spin speed , transfer MAS rotor system . The head must be compatible with automatic sample changer. Temperature changes at the interval narrower than the range of -50 ° C to 80 ° C .

Usage area: For NMR investigations in solutions at variable temperature. 1H NMR, 13C NMR, 31P NMR, DEPT, INEPT, COSY, TOCSY, NOE, 13C HSQC, 13C HMBC.

Keywords: Nuclear magnetic resonance NMR, COSY, DEPT, HMBC, HSQC, NOE

700 MHz NMR spectrometer

Description: 700 MHz NMR spectrometer

Technical specification: 9.4 Tesla permanent magnetic field . Room temperature homogeneity outdoor activities ( shim ) system for optimal magnetic field homogeneity needed for 1D , 2D and 3D experiments without rotation of the sample cuvette , and not less than 20 orthogonal gradient control. Not less than 2 equivalent and interchangeable frequency channels of communication with the full wide -frequency generation in each , and the minimum interval for each channel 6-430 MHz Complete digital phase and amplitude of the best generation of long-term stability to achieve Digital real- time compensation The required frequency change: steps < 0.01 Hz Phase change: steps < 0.01 Grad, with no more than 25 ns duration Radio frequency system output signal phase singalong / accuracy by changing the power attenuation ( monotony ): not more than / - 0.5 and 90 dB power conversion range. Individual and / or along the phase , frequency and / or amplitude of the event time : no more than 25 ns Impulse control temporal resolution of 12.5 ns or less Software -controlled variable temperature unit , the temperature change of 0.1 ° C increments  . Temperature changes in the range - 150 to 180 ° . a) 5 mm head with actively shielded Z - gradient, can apply monitoring / irradiation of the NMR core range from 15N to 31P ( below) as well as 1H and 19F . Automatic selection, setting and atitaikymas all clusters interval from 15N to 31P . The ability to record the 1H and 19F spin interactions termination and vice versa . The minimum required parameters : Signal / Noise: 19F sensitivity ≥ 350:1 (TFT sample , the 1H interactions termination ) 31P sensitivity ≥ 150:1 ( TPP sample) 13C sensitivity ≥ 190:1 (ASTM test) 15N sensitivity ≥ 25:1 (90 % formamide sample) 1H sensitivity ≥ 450:1 (0.1 % EC sample , 200 Hz) Temperature changes at the interval narrower than from - 150oC to 150 oC . b ) CP / MAS head 15N - 31P , 1H ; Rotor size 4 mm, rotation frequency up to 15 kHz; shall be accompanied by a pneumatic module for precise spin speed , transfer MAS rotor system . The head must be compatible with automatic sample changer. Temperature changes in the range of -50 ° C to 80 ° C .

Usage area: for recording NMR spectra from solutions in various temperatures. 1H NMR, 13C NMR, 31P NMR, DEPT, INEPT, COSY, TOCSY, NOE, 13C HSQC, 13C HMBC.

Keywords: Nuclear magnetic resonance NMR, COSY, DEPT, HMBC, HSQC, NOE

ICP deep reactive etching system,

Description: ICP deep reactive etching system,

Technical specification: Homogeneous etching area diameter 15 cm

Usage area: deep reactive ion etching, bulkmicrofabrication

Keywords: deep reactive ion etching, bulkmicrofabrication

System SPECTRUM GX 2000 RAMAN Nr.68891, HATR ACCESSORY FOR SPECTRUM GX

Description: System SPECTRUM GX 2000 RAMAN Nr.68891, HATR ACCESSORY FOR SPECTRUM GX

Technical specification: Diapazone of FTIR spectrum 10 000-200 cm-1, HATR FTIR spectrum diapazone 4000-460 cm-1 ribose

Usage area: FTIR analysis of anorganic, organic ang polymer materials

Keywords: FTIR, HATR