CTF
Search

Results of equipment (192)

Description: Fermentation Kit- BioFlo 110 M1273-1162

Technical specification: total volume 3,0 liters, working volume 0,8-2,2 liters, mixing, 200-240 V

Usage area: Microorganism cultivation

Keywords: fermentation, cultivation

Description: Spiral mixers (DIOSNA SP 24 F

Technical specification: output 24 kg, working volume 45 liters

Usage area: dough mixing

Keywords: dough mixing

Description: Platilab 110 H

Technical specification: temp. range -40C-90C; working volume 110 liters

Usage area: storage of microorganisms

Keywords: freezing, storage

Description: Centrifugal Vacuum Concentrator/Freeze Dryer

Technical specification: Low speed vacuum centrifuge: 1800rpm. Heated compartment temperature range: 30 to 60°C. Minimum pressure rating: <15hPa. Temperature minimum -110°C

Usage area: freeze-drying

Keywords: freeze-drying

Description: Solid-Liquid Extractor

Technical specification: Number of extraction places: 4;valume of basic vessels: 200 ml; recommended working volume: 4x100 ml; Max . temperature: max. 200 °C

Usage area: Extraction

Keywords: extraction

Description: Acoustic spectrophotometer

Technical specification: worging frequency range 4-80 kHz, measurement time 10 s

Usage area: Porous system structure analysis

Keywords: acoustics

Description: SafTest system

Technical specification: Measures percent fat i all food matrices; 570/690 filter for the ParoxySafe and AciSafe, and 550/690 filter for the AldeSafe and AlkalSAfe

Usage area: SafTest system is tests for determine lipid quality and freshness.

Keywords: Quality of fat

Description: Spectrophotometer

Technical specification: UV range 190-1100 nm

Usage area: absorbance measurement

Keywords: spectrophotometer

Description: Dough forming mashine

Technical specification: uotput 120 goods/h, 1.2 kW

Usage area: dough forming

Keywords: dough forming

Description: One-screw extruder Inbramaq “LABOR PQ-30”

Technical specification: output 20-25 kg extruded products/h, 220-380 V, 1760 rpm, 60 Hz, 5 temperature zones: I-20C, II- 40C, III-60C, IV-80C, V-100C

Usage area: production of extruded products

Keywords: extruded products

Description: Baking oven MIWE Condo

Technical specification: 3 baking chambers, output 72-120 baked goods/h, 35 kW

Usage area: baking experiments

Keywords: baking, oven

Description: Thermo - chamber MIWE

Technical specification: working volume 0.98 m3

Usage area: proofing

Keywords: proofing

Description: Vacuum-packaging machine HEFESUS Atchena SLB

Technical specification: output 240 packages/h, 1.5 kW

Usage area: packaging

Keywords: packaging

Description: Electrophoresis unit OmniPAGE

Technical specification: Proteins separation using SDS-PAGE

Usage area: Proteins analysis

Keywords: Unit dimension 19 x 13 x 15 cm; gel size 7.5 x 8 cm; 2 gels; 8 samples per gel

Description: Particle size analyzer

Technical specification: Static light scattering. Measuring from 0,1 to 2000 micrones.

Usage area: Accurate and rapid particle size measurements

Keywords: Particle size distribution, particle size

Description: Texture analyser TA.XT plus (Stable Micro System, UK) with load cell, platform and basic software

Technical specification: Capacity - 50 kg, speed range - 0.01 - 40mm/s. Equipped with cutting, bending, extrusion, tension, penetration probes

Usage area: Measurement of textural properties of foods and cosmetics

Keywords: Textural properties

Description: Works with KT1000131M HPLC-MS

Technical specification: Works with KT1000131M HPLC-MS

Usage area: Works with KT1000131M HPLC-MS

Keywords: HPLC-MS

Description: High performance liquid chromatograph

Technical specification: chromatographic separation of mixtures Maximum pressure up to 5000 psi, maximum flow rate up to 10 ml/min, UV range 190-500 nm.

Usage area: quantitative analysis of individual compounds in mixtures

Keywords: HPLC

Description: Accelerated solvent extraction

Technical specification: Automated extractor with possibility to use different size extraction cells and three different solvents.

Usage area: Accelerated solvent extraction

Keywords: Accelerated solvent extraction

Description: Fermenters

Technical specification: fermenters with working volume 35-500 ml and 300-1200 ml, infrared radiation is used to warm the culture; does not require cooling water. used to warm the culture;

Usage area: Fermentation and cultivation with bacteria, yeasts or fungi.

Keywords: Laboratory fermenters, microbiological culture, fermentation

Description: Electrophoresis technique SDS-PAGE.

Technical specification: 160x(140-160-200-220)mm

Usage area: Proteins separation using SDS-PAGE

Keywords: Proteins analysis

Description: Bottle filler

Technical specification: Semi automatic bottle filler; flexible filling of different 0,3-1 L glass bottles possible

Usage area: Beer filling into the glass bottles

Keywords: Beer filling

Description: Perkin Elmer Clarus500 gas chromatograph

Technical specification: FID detector and non-polar DB-5 capillary column

Usage area: to analyse the volatile aroma components

Keywords: volatiles, chromatography

Description: Meat and fish products formation equipment

Technical specification: Vacuum Stuffer“Frey” F-Line F 55. Fully electronic continual vacuum stuffer for STRAIGHTFILLING, PORTIONING and LINKING with swiveling linking gear and Global drive. Filling power up to 2.900 kg/hour. Housing and hopper completely made of stainless steel. Filling hopper divisible 100 liters or 60 liters. Filling pressure up to max. 25/35 bar. Integrated vacuum system and water separator electronically locked step (optionally). Vacuum pump 16 m³/hour. Portioning range 5 - 100.000 g (5 - 999 g in 0,1 g steps). Portioning speed max. 300 portions/min. Clipper MC12/. Works with clips C1212, C1214 Stainless steel. Base dimensions: 25 x 27cm Straight or crossed clip closing. Magazine capacity 250 clips.

Usage area: Meat and fish products formation

Keywords: Meat and fish technology

Description: Supercritical extractor

Technical specification: Pilot scale (10 L) supercritical fluid extraction system with separators and possibility to add entrainer.

Usage area: Supercritical extraction

Keywords: Supercritical extraction

Description: Supercritical extractor

Technical specification: Laboratory (50mL, 500mL) supercritical fluid extraction system with separators and possibility to add entrainer.

Usage area: Supercritical extraction

Keywords: Supercritical extraction

Description: Water activity measurement, CR400 CR-400, Konica Minolta

Technical specification: aw measurment from 0.05 to 0.95

Usage area: Water activity measurement

Keywords: Water activity

Description: Equipment of Dairy Components Concentration

Technical specification: Membrane filtration equipment (4 flat sheet membranes; max. inlet pressure: 7 bar; max. operating temperature: 80 °C; pH rage: 1-14; cross-flow: 3-10 l/min); spray dryer (inlet air temp.: 40-230 °C; drying air throughput: from 100 to 300 m3/HR; peristaltic pump with flow rate up to 32 ml/min); sublimator (9 drying programs with steps (temperature, pressure and time); volume: 95 l; capacity: 5 kg/24 h; shelf temp.: till 80 °C)

Usage area: Membrane filtration equipment is used for dairy and whey ultra-and micro-filtration; Spray dryer - for drying of dairy products by hot spraying method; sublimator - for drying of dairy and other foods by sublimation (in cold and vaccum) method.

Keywords: Microfiltration; Ultrafiltration; Drying; Freeze-drying; Sublimation

Description: Equipment of Dairy Thermal Treatment in Ultra High Temperature

Technical specification: Small-scale pasteurization and sterilization flow system (thermal treatment temperature: till 150°C; holding time: from 2 s till 2 min; average capacity: 10l/h; pressure: 1-5 bar; weight volume hopper: 5 l; tubular and plate heat exchangers)

Usage area: Thermal treatment of raw milk (pasterization, sterilization and ultra hight thermal treatment (UHT))

Keywords: Milk pasterization, Sterilization; UHT

Description: Technological Equipment of Cheese Small-scale Production

Technical specification: Cheese vessel (capacity: 50 l; temperature rage: 4-90 °C; with cheese harp); cheese press (max. capacity: 50 kg; pressure: up to 10 bar; pneumatic); climatic chamber (temperature and relative humidity control); automated multipurpose and pressure vessel (internal volume: 20 l; temperature inside the container: up to 140 ° C, pressure: till 3 bar, automatic temperature and pressure control, three types of mixers)

Usage area: The production of various types of cheese, their formation, removal of whey; cheese ripening in the regulated environment.

Keywords: Curd cheese; Fermented cheese, Melted cheese; Cheese ripening

Description: Gas analyser OPTIMA7 BIOGAS

Technical specification: Operatiing temperature 5-45 °C, max. 95 % RH, measurement range: 0-21 vol. % O2, 0-100 vol. % CH4, 0-60 vol. % CO2

Usage area: O2, CH4, CO2 measurements in gas

Keywords: O2, CH4, CO2, gas

Description: Potentiostat mAUTOLAB

Technical specification: Potential range /- 5 V, Current ranges 10 mA to 10 nA

Usage area: Electrochemical investigations of organic materials, evaluation of energy levels of organic molecules

Keywords: oxidation-reduction potential, jonizacjos potencialas, elektroninio giminingumo energija

Description: Comprehensive LECO GC´GC-TOFMS 4D system

Technical specification: Comprehensive GC´GC system with time-of-flight TOFMS detector

Usage area: Determination and identification of volatiles in the liquid samples and in the headspace of samples (vapour phase)

Keywords: GC´GC system

Description: UV Vis spectrometer Lambda 35

Technical specification: UV-Vis spedtrum registration 200-1000 nm

Usage area: Electronical spectrum of solutions registration 200-1000 nm

Keywords: UV-Vis

Description:

Hybrid mass spectrometer

Technical specification:

Separation of compounds and recording of UV spectra in the range of 200-500 nm, and MS spectra in the range of 20-8000 m/z with the accuracy of less than 1 ppm.

Usage area: Chromatographic separation of compounds and quantitative or qualitative analysis of individual compounds

Keywords: UPLC-MS

Description: Distiller Buchi Glass Oven B-585

Technical specification: Temperature range 40-300oC; drying volume upto 250 ml; Kugelroh distillation volume from 5 to 40 ml

Usage area: Equipment for distillation, sublimation, freeze-drying or drying of organic materials in vacuum

Keywords: sublimation, drying, distillation, vacuum

Description: Photoelectron spectrometer

Technical specification: Measurement range 4-6 eV

Usage area: The measuremnts of ionisation potencial of organic materials, measuremnts of work funtion of metals and inorganic semiconductors

Keywords: Photoelektron spectroscopy, ionisation potential, work funktion, photoefect

Description: Set of equipment for sublimation

Technical specification: Possible ammounts for sublimation is up to 100 g; achievable vacuum up to 10-3 mbar, condenser could cooled by water

Usage area: Sublimation of the organic materials

Keywords: sublimation

Description: Biodegradability measuring complex

Technical specification: Measuring range (oxygen concentration) from 0 to 4.0 mg / l.

Usage area: Measuring of biochemical oxygen demand

Keywords: Biochemical oxygen demand, biodegradability

Description: Optical tensiometer (contact angle meter)

Technical specification: Measuring range 0-180o, 0.01-1000mN/m

Usage area: Optical tensiometer allow direct measurements of surface tension, interfacial tension, contact angles. It is possible to get information on material properties such as: wettability, absorption, surface free energy, adsorption, spreading.

Keywords: surface, contact angle, surface tension

Description: Preparative chromatography system

Technical specification: Liquid or Solid Sample Modes, Solid Injection: up to 75g; 4 Independent channels with up to four solvents in a single run; Combination of up to 2 UV signals plus ELSD with slope and/or threshold detection.

Usage area: Purification of organic materials

Keywords: Flash chromatography, purification, organic materials, preparative scale

Description: System for charge mobility measurements

Technical specification: CELIV method, max voltage 10V, TOF method max voltage 1000V. Excitation is done with 276 nm, 355 nm, 530 nm light by nanosecond laser.

Usage area: Investigation of charge transport properties of organic semiconductors

Keywords: charge mobility

Description: Spectrophotometer GENESYS 8

Technical specification: 190-1100 nm

Usage area: Spectrophotometric analysis

Keywords: Spectrophotometry

Description: Luminescence spectrometer Perkin Elmer LS-55

Technical specification: Excitation spectra wavelength range: 200-800 nm; emission spectra wavelength range: 200-650 nm.

Usage area: For recording of luminescence spectra of solutions and hard samples

Keywords: Fluorescence, phosphorescence

Description: Drug dissolution test

Technical specification: 6 places

Usage area: Drug release studies

Keywords: Drug release

Description: FTIR spectrometer Perkin Elmer Frontier

Technical specification: Spectrum range: 600-4000 nm.

Usage area: For recording of FTIR spectra of hard samples

Keywords: FTIR spectra

Description: Shrinkage temperature determination instrument

Technical specification: Instrument is suitable for hide/skin/leather shrinkage temeprature determination under 100 degrees.

Usage area: Instrument for leather shrinkage temperature mesearment under 100 degree (ISO 3380).

Keywords: Leather, shrinkage temperature

Description: Leather processing equipment containing 1) apparatus for leather tanning process imitation and 2) shaker for solutions preparation

Technical specification: Leather processing equipment containing 1) apparatus for leather tanning process imitation and 2) shaker for solutions preparation

Usage area: Equipment is suitable for leather processing in laboratory conditions and for solutions preparation for analysis

Keywords: Leather, processing, shaker

Description: Dielectrical spectrometer Agilent E4980A Precision LCR meter

Technical specification: Temperature interval: -60 - 300°C.

Usage area: Measurements of dielectrical properties of materials

Keywords: Dielectrical properties

Description: Thermal Analyser Perkin Elmer TGA4000

Technical specification: Temp.range 30-1000 ºC, heating rate 0.1-100 ºC/min, nitrogen or oxygen environment.

Usage area: For mass loss analysis by heating

Keywords: Thermogravimetry

Description: Kugelrohr distillation system

Technical specification: temperature range 20-200 °C, distillate volume - 1-330 ml.

Usage area: Liquids distillation under oil pump vacuum. Sample range per single run - 1-330 ml.

Keywords: kugelrohr, distillation.

Description: Automated Soxhlet extraction

Technical specification: 2 ceramic heating plates; Extraction thimbles - 130 ml; Volume of Soxhlet glass chamber - 190 ml.

Usage area: Fat extraction for fat determination. Continuous extraction of solids.

Keywords: extraction, soxhlet

Description: Constant climate chamber Memmert GmbH HCP-246

Technical specification: Temp.range 20 - 90 ºC, ±0.1°C; humidity range 20-95 %, ±1%.

Usage area: Environment simulation

Keywords: Environmental simulation

Description: Disperser IKA T 50 digital ULTRA-TURRAX

Technical specification: Speed range 600-10000 rpm; volume range 0.25-30 l

Usage area: Preparation of dispersions, emulsions

Keywords: Dispersion

Description: Polarizing microscope (Olympus BX41) with light source and hotstage

Technical specification: Temperature range 150-420oC; Reflection and transmission modes; Polarizator; 50, 200, 500 X magnification. LED Light source for reflection mode. Photocamera.

Usage area: The observation of phase transitions of organic materials, investigation of phase transitions of liquid crystals, observation of the surfaces.

Keywords: microscopy, polarisation, liquid crystals

Description: Spin Coater SPS SPIN-150

Technical specification: Speed 0-10000 rpm, sample max. diameter 150 mm.

Usage area: For film casting

Keywords: Film casting, spin coating

Description: Micro Viscoamylograph Brabender

Technical specification: Temp.range 1-100 ºC, sample volume 100 ml

Usage area: For investigation of pasting properties of starch derivatives

Keywords: Starch, pasting, viscosity

Description: Melt flow rate meter Thermo C-Flow

Technical specification: Temp.range 50- 400 ºC, extrusion barrel: diameter 9.55 mm, length 170 mm.

Usage area: For determinastion of melt flow rate of thermoplastics

Keywords: Thermoplastics, melt flow rate

Description: Melting point apparatus

Technical specification: Melting or boiling point range 30-400°C

Usage area: Melting point determination of crystalline compounds. Boiling point determination under atmospheric pressure.

Keywords: Melting point, boiling point

Description: Melting point apparatus

Technical specification: Melting or boiling point range 30-400°C

Usage area: Melting point determination of crystalline compounds. Boiling point determination under atmospheric pressure.

Keywords: Melting point, boiling point

Description: Glass oven Kugelrohr with accessories

Technical specification: Temperature range: 30-300°C. Appropriate amount of substance per cycle: 0,5-40 ml.

Usage area: For distillation, sublimation, drying, freeze drying under vacuum down to 0,01 mbar and temperature limit to 300 °C. For distillation of viscous liquids.

Keywords: kugelrohr, distillation, sublimation, drying, freeze drying.

Description: Glass oven Kugelrohr with accessories

Technical specification: Temperature range: 30-300°C. Appropriate amount of substance per cycle: 0,5-40 ml.

Usage area: For distillation, sublimation, drying, freeze drying under vacuum down to 0,01 mbar and temperature limit to 300 °C. For distillation of viscous liquids.

Keywords: kugelrohr, distillation, sublimation, drying, freeze drying.

Description: Turbo molecular vacuum system (end vacuum ~10 -7 mbar)

Technical specification: End vacuum - 1•10-7 mbar; Pumping speed for N2 - 35 l/s; Compression ratio for N2 - 1·1011; External vacuum sensor; Flange (in) - 40 ISO-KF.

Usage area: Drying of solids, desorption, sublimation.

Keywords: Sublimation, drying, turbo molecular pump.

Description: Turbo molecular vacuum system (end vacuum ~10 -7 mbar)

Technical specification: End vacuum - 1•10-7 mbar; Pumping speed for N2 - 35 l/s; Compression ratio for N2 - 1·1011; External vacuum sensor; Flange (in) - 40 ISO-KF.

Usage area: Drying of solids, desorption, sublimation.

Keywords: Sublimation, drying, turbo molecular pump.

Description: Spectrophotometer Konica Minolta CM-5

Technical specification: Standard observer at 2° ir 10°; standard illuminant C and D65; color spaces L*a*b, L*C*h, Hunter Lab, Yxy, XYZ, Munsell and color differences

Usage area: Determination of color characteristics

Keywords: Color characteristics

Description: Microbial Oxidative Degradation Analyzer Saida FDS Inc. MODA-6

Technical specification: Temperature interval: 45 - 65°C; 6 reaction columns.

Usage area: Assesment of biodegradability of materials under aerobic conditions according to CO2 emission

Keywords: Biodegradability, aerobic conditions, carbon dioxide

Description: Vacuum sublimation equipment

Technical specification: vacuum up to 0,001 mbar by LN freezing. Sublimation modules for amounts from 1 to 100 g sample of material.

Usage area: For sublimation, freeze drying, drying, removing of residual solvents of solid materials.

Keywords: sublimation, drying, freeze drying.

Description: Preparative chromatography system Sepacore Line C-600

Technical specification: Controlled pump flow rate - 2,5 – 250 ml/min; Pump working pressure limits - 0 – 50 bar; UV detection spectral range - 190 – 740 nm; UV detection limits 0,001-5 A

Usage area: Preparative chromatographic purification of organic compounds, pure compounds separation under isocratic or gradient flow. Automated purification process.

Keywords: preparative chromatography

Description: X-ray single crystal diffraction spectrometer

Technical specification: X-Ray power source: 50W of rays power. Double focuse optic. Detector: sensitivity not less than 175 e-/photon. Low temperature module with lowest temperature value 200K. Dry air module up to –70°C dew point and flexible airflow rate not less than 25L/min. Dynamic range > 1:20000. 16 000 000 pixels.

Usage area: Single crystal research. Determination of molecular structure.

Keywords: Single crystal, X-ray

Description: FT-IR spektrometer

Technical specification: Optic range: 8000-350 cm-1. Signal-to-noise ratio >8000:1. Resolution: <0,4 cm-1. Wave length precision <0,01 cm-1 (at 2000 cm-1). Accessories for transmission measurement. Accessories for ATR measurements. ATR spectral database of industrial compounds.

Usage area: Liquid, solid and gaseous phase infrared spectral measurements. Compound search in spectral database.

Keywords: FT-IR spectrometer

Description: FT-IR spectrometer with RAMAN module

Technical specification: Measurement under vacuum (3,5 mbar) or under atmospheric pressure. Optical spectral range - 8000-50 cm-1. Signal-to-noise ratio - 8500:1. Resolution: >0,18 cm-1. Wavelength tolerance <0,01 cm-1 (at 2000 cm-1). Accessory for transmission measurement. Platinum ATR accessory. Compound search in spectral database. Accessory for variable temperature measurement in range -190 to +250°C. RAMANO spectra. Laser 1064 nm, emmition power 0,5 W. Resolution for RAMAN spectra >0,5 cm-1. 3D RAMAN scanning.

Usage area: Liquid, solid and gaseous phase infrared spectral measurements. Compound search in spectral database. Transmition spectral research in temperature range from -190 to +250°C. RAMAN spectra of solid and liquid compounds. 3D RAMAN scanning. Qualitative RAMAN and IR spectral analysis.

Keywords: IR, FT-IR, MID-IR, FAR-IR, RAMAN, Spectral date base, variable temperature IR

Description: Balances for big weights, model: MSE 12201S-0CE

Technical specification: Weighing capacity:12000g; Readability: 0,1 g; Repeatedability: ≤±0,05 g. Linearity: ±0,1 g.

Usage area: to weight metal vessel and reactors

Keywords: Balances

Description: Analytical balances (0,001 mg) and balances table

Technical specification: Weighing capacity:31g; Readability: 0,001 mg; Repeatedability: ±0,002 mg. Average response time - 15 s. Pan size - Ø 30 mm.

Usage area: For precise weighing of micro analytical samples.

Keywords: Micro balances

Description: Photochemical reactor, Ace Glass

Technical specification: Volume of the reaction vessel - 250 mL; Operating volume - 125 mL; Power of light source - till 450 W.

Usage area: Radical reactions in solution

Keywords: photochemical reactor, UV

Description: Microwave reactor with hydrogenation module, Discover LabMate, CEM

Technical specification: Microwave radiation power - 300 W. Temperature regulation from - 90 °C till +300 °C. Volume of reaction vessel working at the atmospheric pressure till 125 mL. Pressure adjustment and regulation range from 0 till 20 bar. Adapter for gaseous reagents

Usage area: To perform precision chemical reactions under microwave heating and tracking pressure. The reaction with gaseous reagents or inert conditions at elevated pressure.

Keywords: microwaves, gas addition module

Description: spincoater, Chemat Technology Spin-Coater KW-4A

Technical specification: 2-Stage spinning: 500-2500 rpm; 1000-8000 rpm. Chucks for different size substrates

Usage area: Thin film formation from solution on the substrate

Keywords: spin coating, thin film

Description: Cyclic voltammetry apparatus (potentiostat), Bio-logic Sas SP-150

Technical specification: Current ranging: 10 μA to 800 mA Current resolution: 760 pA. Control voltage: ±10 V. Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V. Voltage resolution: 5 μV EIS measurement from 10 µHz to 1 MHz.

Usage area: Cyclic voltammetry, determination of oxidation reduction potentials of te organic materials

Keywords: potentiostat, CV, cyclic voltammetry

Description: Spectrofluorimeter for measuring steady state luminescence spectra and quantum yields in the UV – NIR spectral range with single photon counting sensitivity. Spectrometer for measuring fluorescence lifetimes spanning the range from picoseconds to microseconds based on the technique of time correlated single photon counting, Edinburgh Instruments FL920

Technical specification: Lifetime range: 100ps – 50μs (time correlated single photon counting). Fluorescence red sensitive detector (200 – 870nm).

Usage area: Measurement of fluorescence spectra and quantum yields of liquid and solid samples. Measurement of fluorescence lifetime of liquid and solid samples.

Keywords: fluorescence, quantum yield, fluorescence lifetime

Description: Pressure filtration vessel

Technical specification: Internal diameter: 142 mm, Flow: ∆p = 1 bar for water ≥2 l/min pro 0,2 μm, ≥4,5 l/min pro 0,45 μm, ≥11 l/min pro 0,8 μm membrane Filtration area: 130 cm² Max. Working pressure: ≥7 bar

Usage area: Filtration of viscous liquids, sterile filtration

Keywords: Pressure filtration

Description: Interferometer, MarSurf WS 1

Technical specification: High-precision, non-contact measurement of surface texture. Optical surface sensor operates on the basis of white-light interferometry. This technology enables rapid, high-precision recording of surface topography on a wide range of materials. Vertical resolution 0.1 nm. Measuring range (vertical) 100 μm.

Usage area: Surface topography measurements

Keywords: interferometry, surface topography

Description: Nanosecond laser flash photolysis measurement system

Technical specification: Nanosecond laser NL301G-10-SH-TH-FH (up to 10 mJ), UV-spectrophotometer IJ, fiber, UV-IJ source

Usage area: Investigations of photochromic compounds in solution using nanosecond laser pulses

Keywords: flash photolysis

Description: Microwave reactor with hydrogenation module, Discover LabMate, CEM

Technical specification: Microwave radiation power - 300 W. Temperature regulation from - 90 °C till 300 °C. Volume of reaction vessel working at the atmospheric pressure till 125 mL. Pressure adjustment and regulation range from 0 till 20 bar. Adapter for gaseous reagents

Usage area: To perform precision chemical reactions under microwave heating and tracking pressure. The reaction with gaseous reagents or inert conditions at elevated pressure.

Keywords: microwaves, gas addition module

Description: AFRICA (Automated Flow Reaction Incubation Control Apparatus) with FLLEX and PCM.

Technical specification: Completely chemically inert synthesis environment. Four independent liquid-filled pumps with a debit control from 2.5 to 2500 ul / min range. Maximum system pressure up to 20 bar. 1 1/4, 1/16 ml micro reactors with 2 or 3 of the liquid inlet. Two thermostats: 0-150 ° C and 40-250 ° C temperatures. Liquid extraction module. Reagent input module. Clean solvent was added to the module. The product manifold. Software manages the performance of chemical processes.

Usage area: Investigations of homogeneous chemical processes. Reaction performance under unusual conditions: very rapid mixing, the suspension is very fast, quick analysis, implementation absolute terms, highly exothermic reactions, the use of precise control of the reaction parameters of performance. Multistep reaction performance. Precise reaction optimization process of production. Quick extraction performance.

Keywords: micro reactor, micro extractor, flow chemistry

Description: Schleibinger Geräte GmbH VICASONIC ultrasound apparatus

Technical specification: 10 imp./s speed and 54kHz frequency

Usage area: investigation of cement stone properties

Keywords: ultrasound analysis

Description: equipment of powder homogenizing WAB TURBULA T2F

Technical specification: mixing of Powder material of all types

Usage area: Powder material mixing

Keywords: Powder material homogenizing

Description: sieve analysisi instrumen Sonic Sifter

Technical specification: sieve from 3 µm to 5,6 mm

Usage area: sieve analysis

Keywords: sieve analysis

Description: Netzsch 409 PC Luxx simultaneous thermal analysis instrument with ceramic sample handlers and crucibles of Pt-Rh.

Technical specification: heating rate of 15°C/min, the temperature ranged from 30°C to 1000°C under a nitrogen atmosphere

Usage area: DSC-TG analysis

Keywords: DSC-TG

Description: Fixed bed adsorption unit FBAU/EV

Technical specification: CO2 reducer flow 0-1 l/min, heli - 0-5 l/min. heat element 0,5 kW

Usage area: Investigation of adsorption properties of materials.

Keywords: adsorbtion

Description: Spray dryer MSD/EV

Technical specification: Peristaltic pump 0-1,5 l/h. 3 kW heat element. Temperature range 280 °C

Usage area: obtaining solid matter particles from suspensions

Keywords: suspension, drying

Description: Heat transfer pilot plant with tube-in-tube, shell-and-tube and plate exchangers SCTA/EV

Technical specification: Flowmeters 0-1000 l/h, 4-20 mA sygnal

Usage area: heat transfer processes analysis in heat exchangers

Keywords: Heat transfer

Description: Solid-liquid extraction pilot plant SLA/EV

Technical specification: Pump 0-12 l/h. Screw speed 0-10 min-1

Usage area: selective components of the extraction solvents extractive phase equilibrium and kinetic studies

Keywords: extraction

Description: tray dryer apparatus TD/EV

Technical specification: Fan 0-1400 min-1, power 0.3 kW. 9 heat element each 300 W

Usage area: convection material drying

Keywords: drying

Description: liquid mixing apparatus LM/EV

Technical specification: Mixer 140 W, 30-1000 min-1

Usage area: liquid mixing

Keywords: liquid mixing

Description: Filter press and micro filter pilot plant FP-1S/EV

Technical specification: Pump 0-128 l/h. 3 manometers 0-6 bar, 4-20 mA sygnal

Usage area: filtration of suspension with filter press and microfilter

Keywords: filtration

Description: Centrifugal pumps in series and parallel test bench BP-1S/EV

Technical specification: Centrifugal pump 0-15 m3/h, 0-3000 min-1

Usage area: settings of various pump parameters

Keywords: pump

Description: Liquid-liquid extraction pilot plant LLA/EV

Technical specification: Mixer 0-1000 min-1, pump 0-34 l/h

Usage area: valuable or toxic substances produced by the solutions, the concentration of the solutions.

Keywords: solution, extraction

Description: Spectrophotometer T70, PG Instruments limited

Technical specification: Wavelength 190-1100 nm; Sample Module 8 Cell

Usage area: Determination of P, Fe

Keywords: UV/VIS

Description: Microscope Olympus SZX7 for crystals

Technical specification: 40x zoom

Usage area: Crystal analysis

Keywords: Optical microscope, crystal analysis

Description: Continuous distillation pilot plant DCA/EV

Technical specification: Heat elements 300 and 2500 W. Pump 0-12 l/h

Usage area: separation of heterogeneous mixtures of liquids

Keywords: distillation

Description: Thin film evaporation pilot plant ESSA/EV

Technical specification: Pump 0-24 l/h. Vakuum pump 0,7 kW. 0-1500 min-1, mixer power 1 kW

Usage area: Exclusion of salt from solutions and the heat balance studies.

Keywords: evaporation

Description: Double-effect falling-film evaporation pilot plant EDEA/EV

Technical specification: Pump 0-34 l/h

Usage area: separation of solvent from solutions, material concentration and mass and energy transfer processes analysis

Keywords: crystallization

Description: optical microscope Axiolmager Z2

Technical specification: Magnification up to 500 times.

Usage area: The study of materials surface and texture

Keywords: optical microscope

Description: X-ray diffractometer for powder and layers ADVANCE D 8

Technical specification: Vertical goniometer, Theta/2Theta or Theta/Theta geometry. Max. usable angular range: –110° < 2Theta ≤168°. Smallest addressable increment: 0.0001°. Instrument alignment: Equal or better than ± 0.01° 2Theta; NIST SRM 1976a. Maximum angular speed 20°/s. Point detector: Scintillation counter with graphite monochromator, 1-D detector: LYNXEYE with Ni-filter.

Usage area: powder,liquids, thin films X-ray analysis

Keywords: X-ray analysis

Description: bending testing machine

Technical specification: the accuracy class - 1 (DIN EN ISO 7500-1)

Usage area: bending testing machine

Keywords: Compression- and bending tests

Description: Climatic chamber

Technical specification: capacity - 350 l. humidity 60 -95 % rH. Temperature range -20ºC- 50ºC

Usage area: for environmental conditions maintenance

Keywords: Climatic chamber

Description: Analytical electronic balance, "Radwag MXA 5", (d=1µg)

Technical specification: Maximum sample weight - 5g. Scaling value - 1μg. Weighing repeatability - `3μg.

Usage area: Sample mass measurements (0 – 5g, d=1µg).

Keywords: Analytical balance

Description: Spectrophotometer "GENESYS 8"

Technical specification: Wavelength range - 190-1100nm. Accuracy - <1nm.

Usage area: Sample UV-VIS spectroscopy analysis.

Keywords: UV-VIS spectroscopy analysis.

Description: Gas chromatograph with TCD detector

Technical specification: Alltech CTR 1 column, maximum available operating temperature 275° C

Usage area: Quantitative and qualitative analysis of gases (O2, N2, CH4, CO2, CO)

Keywords: GC-TCD

Description: Linseis TMA PT1000 Thermomechanical Analyzer

Technical specification: Temperature interval - from room temperature to 1000 °C; sample size - 30 mm; force - from 1 to 5.7 N; frequency - from 1 to 5 Hz

Usage area: The evaluation of changes in the sample dimensions (volume) by applying constant or alternating mechanical load while the substance is subjected to a controlled temperature program in a specified atmosphere. These tests can be performed: visco-elastic behavior, deformation, 3 point bending test, change of volume and penetration.

Keywords: Thermomechanical analysis

Description: Differential scanning calorimeter DSC214Polyma

Technical specification: Temperature interval: from -30 to 600 °C; min. heating rate - 0.001 °C/min.

Usage area: The evaluation of energy, which is needed to uniform sample`s and reference`s temperatures while the substance is subjected to a controlled temperature under specified atmosphere. This method allows to determine: specific heat, melting temperature, the change of enthalpy, glass transition temperature, decomposition temperature and other thermal conversions.

Keywords: Differential scanning calorimetry

Description: PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Technical specification: Aerosol concentration measurement range - 0.001 to 400.0mg/m3. Particle size range for maximum accuracy - 0.1 to 10μm.

Usage area: Measurements of personal exposure to aerosol particles in the workplace.

Keywords: Aerosol particles

Description: Optical aerosol particle counter, Handheld IAQ 3016

Technical specification: Measuring range - 0.3-10.0 µm. Flow rate - 2.83 l / min. Measuring the number of channels - 6 (0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm). The maximum instantaneous concentration - 140 particles/cm3.

Usage area: Aerosol particle dispersion composition in indoor and outdoor air (0.3 - 10.0μm).

Keywords: Aerosol particles.

Description: Gas chromatograph with FID detector CLARUS 500

Technical specification: Alltech AT-WAX capillary column, maximum available operating temperature 260 °C

Usage area: Quantitative analysis of volatile and semi-volatile organic compounds

Keywords: GC-FID

Description: UV/VIS spectrophotometer Lambda 25

Technical specification: Measuring range from 190 to 1100 nm

Usage area: UV/VIS absorption/transmittance spectra

Keywords: UV/VIS absorption, UV/VIS transmittance

Description: Spectrometer AANALYST400

Technical specification: D2 background correction, flame acetylene-air or acetylene-nitrous oxide

Usage area: Quantitative analysis of metal solutions by atomic absorption and atomic emission spectroscopy methods

Keywords: AAS

Description: Autolab PGSTAT12 Potentiostat/Galvanostat 

Technical specification: low noise potentiostat/galvanostat capable of measuring or applying a maximum current of 250 mA, with a compliance voltage of 12 V and the possibility to do iR-compensation

Usage area: Electrochemical research, voltammetric analyses

Keywords: Electrochemical analysis

Description: Gas chromatograph-mass spectometer CLARUS 500

Technical specification: Elite-5MS capillary column, maximum available operating temperature 330/360 °C

Usage area: Quantitative and qualitative analysis of volatile and semi-volatile organic compounds

Keywords: GC-MS

Description: Mass spectometer CLARUS 500

Technical specification: Electron impact ionization, ionization energy 70eV

Usage area: Detector in CLARUS GC-MS system

Keywords: MS

Description: Indoor air quality monitor "Aeroqual IQM 60"

Technical specification: Gaseous pollutant name - measuring range; the lowest detection limit. CO2 - 0-2000 ppm; 6 ppm. CO - 0-100 ppm; 0.2 ppm. NO2 - 0-0.2 ppm; 0.001 ppm. VOC - 0-20 ppm; 0:01 ppm. O3 - 0-0.5 ppm; 0.001 ppm. Particle counter - 8 channels from 0.3 to 10.0μm.

Usage area: Measurements of carbon monoxide, carbon dioxide, nitrogen dioxide, ozone, volatile organic compounds, and aerosol particle concentrations at ambient and indoor air.

Keywords: Carbon monoxide, carbon dioxide, nitrogen dioxide, ozone, VOCs and PM.

Description: PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Technical specification: Aerosol concentration measurement range - 0.001 to 400.0mg/m3. Particle size range for maximum accuracy - 0.1 to 10μm.

Usage area: Measurements of personal exposure to aerosol particles in the workplace.

Keywords: Aerosol particles

Description: Heating Circulators, Julabo HE-4

Technical specification: Working temperature range 20-250 °C±0.01; Volume 3-4.5 l

Usage area: Temperature control

Keywords: Thermostatation

Description: Flame Photometer, PFP7, operating and Service Manual

Technical specification: Limits of Detection: Na, K-0.2 ppm; Ca-15 ppm

Usage area: Determination of Ca, Na, K

Keywords: Flame photometric analysis

Description: Programmable rapid distillation system with external titratinion, Gerhardt

Technical specification: Digestion; Distillation; Automatic titration; Combined pH electrode

Usage area: Determination of N

Keywords: Nitrogen

Description: Laboratory centrifuge for tubes LMC-3000

Technical specification: 3000 rpm

Usage area: Wide range of analytical applications

Keywords: centrifuge

Description: Compact Lab Fluid Bed Dryer/Granulator/Coater

Technical specification: Control of Spray Solution, of Air Flow, of Temperature

Usage area: Solid Material Granulation, coating

Keywords: Granules, Film

Description: Resistance Meter

Technical specification: The Measuring Range from 0,1 Ω to 20 GΩ, possibility to measure thermostated sample from -50 to 50 °C

Usage area: Measurement of surface resistance

Keywords: Surface electrical resistance, electrical conductivity

Description: High performance liquid chromatograph vith mass spectrometer

Technical specification: Separation of mixtures into individual compounds and recording of their UV and MS spectra. Maximum pressure up to 5000 psi, maximum flow rate up to 10 ml/min, UV range 200-700 nm, MS range 20-2000 m/z.

Usage area: Separation of mixtures and quantitative and qualitative analuysis of indivisual compounds

Keywords: HPLC-MS

Description: TAM AIR III calorimeter.

Technical specification: The range of measurement 600 mW, the sensitivity of the signal 4 ìW, the time constant 500 s,

Usage area: measurement of heat flow of processes

Keywords: calorimetric analysis

Description: vibrating disc mill Pulverisette 9

Technical specification: ground particle size < 80 µm

Usage area: Rigid materials grinding (ability to reach ground particle size of <80 microns)

Keywords: Rigid materials grinding

Description: The hydraulic compression testing machine

Technical specification: max. Compression force 1200 kN

Usage area: Determination of compressive and flexural strength of binding materials

Keywords: The compressive and flexural strength

Description: CILAS 1090 LD laser scattering particle size distribution analyzer

Technical specification: Size of measured particles 0,04-500 µm

Usage area: The particle size distribution

Keywords: The particle size distribution

Technical specification: Analysis temperature 40-300 oC

Usage area: Analysis of liquid mixtures and identification of mixture components

Keywords: Gas chromatography, capilary column, EI MS detector

Description: Rheometer Physica MCR (Anton Paar, Austria)

Technical specification: Rheological measurements in controlled shear rate mode - from 1x10-6 to 3000 1/s and controlled shear stress mode - from 1x10-7 to 3000 1/min. Equipped with Peltier temperature system.

Usage area: Rheological measurements in oscillatory mode, using systems: plate-plate, cone-plate; rheological measurements in rotational mode using system: cylinder-cylinder.

Keywords: Rheological characteristics

Description: Sepacore Basic Flash System, Buchi Labortechnik

Technical specification: recorder, UV detector, sample inlet block, manifold, column KX16

Usage area: Proteins isolation

Keywords: Ion exchange chromatography

Description: Works with KT1000130M HPLC

Technical specification: Works with KT1000130M HPLC

Usage area: Works with KT1000130M HPLC

Keywords: UV

Description: Meat and fish texture modeling equipment

Technical specification: Manual hand injector Ingmat. Suitable for bone in and boneless product. Powerful self priming plastic pump Handy

Usage area: Meat and fish texture modeling

Keywords: Meat and fish technology

Description: High performance liquid chromatograph

Technical specification: chromatographic separation of mixtures Maximum pressure up to 5000 psi, maximum flow rate up to 10 ml/min, UV range 190-500 nm.

Usage area: quantitative analysis of individual compounds in mixtures

Keywords: HPLC

Description: CE440 Elemental Analyser

Technical specification: Accuracy: With standard organic compounds, ±0.15% absolute plus ±0.15% relative Sample Size: Typically 1-5 mg; up to 500 mg for samples with low carbon content Analysis Time: Less than 5 minutes for CHN Range: 100 ppm to 100% Detector: Thermal conductivity System Sensitivity: ±1 microvolt Analytical Sensitivity: Less than 1 microgram

Usage area: combustion analysis

Keywords: combustion analysis

Description: Analytical balances

Technical specification: Weighing capacity: 220/100; Readability: 0,1/0,01 mg; Repeatedability: ≤±0,02/0,1 mg. Linearity: ≤±0,03/0,2 mg.

Usage area: weighing of samples for analysis

Keywords: balances, analytical

Description: Benchtop chemical crystallography system XtraLab mini (Rigaku)

Technical specification: Mercury CCD detector, power 600W

Usage area: investigation of monocrystals of organic and inorganic materials, study of crystal cage, identification of the chemical structure

Keywords: monocrystal, crystal cage, x-ray diffraction

Description: Ultrasound generator K8-1

Technical specification: Ultrasound frequenz 850kHz

Usage area: For dispersion of materials of liquid materials

Keywords: Ultrasound, generator

Description: Absorption pilot plant ADSA/EV

Technical specification: Gas reducers 0-600 Nl/h and 0-6000 Nl/h. Pump 0-270 l/h

Usage area: Excretion of components of gas mixtures, gas cleaning from harmful impurities, gas drying, gas and liquid phases of the system equilibrium and kinetics.

Keywords: Absorption

Description: Potentiostat/Galvanostat BioLogic SP-150 for fundamental electrochemistry, sensors, corrosion, energy sources coatings investigations

Technical specification: Current ranging: from 10 µA to 1 A and from 1 µA to 1 nA; Control voltage: ±10 V; EIS: 10 µHz to 1 MHz

Usage area: Fundamental electrochemistry, Sensors, Corrosion, Energy sources, Coatings investigations

Keywords: Potentiostat-galvanostat, electrochemical impedance spectroscopy

Description: Equipment of Dairy Mechanical Processing

Technical specification: Separator (max. capacity: 40 l/val; max. rotating speed: 8500 min-1); homogenisator (flow rate: 10-22 l/h; pressure: till 1000 bar; stages: two); butter churn (working capacity: 4-12 l; working rotation speed: 140 rpm)

Usage area: Separator is used for separation of lipids from raw milk; homogenisator - for preparation of homogeneous emulsions and splitting of milk fat droplets; butter churn - for production of butter and spreads

Keywords: Separation; Homogenisation; Butter churning

Description: UV/VIS spectrophotometer Lambda 35

Technical specification: Measuring range from 190 to 1100 nm, the ability to measure the surface reflection spectra

Usage area: UV/VIS absorption/transmittance, surface reflectance spectra

Keywords: UV/VIS absorption, UV/VIS transmittance, UV/VIS surface reflectance

Description: UV/VIS spectrophotometer Lambda 25

Technical specification: Measuring range from 190 to 1100 nm

Usage area: UV/VIS absorption/transmittance spectra

Keywords: UV/VIS absorption, UV/VIS transmittance

Description: Tensiometer equipped with Vilhelmy plate and DoNuoring systems

Technical specification: Measurements range 1 - 999 mN/m

Usage area: Surface and interfase surface tension measurements

Keywords: Surface tension, interfase surface tension

Description: Kjeldahl distillation unit, "UKD 130"

Technical specification: Setting limits - up to 1 mg Kjeldahl nitrogen in the test sample. The best results are obtained when the sample is 10-15 mg of ammonium nitrogen.

Usage area: Determination of the nitrogen content in aqueous solutions based on Kjeldahl method.

Keywords: The nitrogen content.

Description: Small tabletop muffle "Thermolyne 1400 Furnace"

Technical specification: Operating temperature range - 0-1100 ° C. The interior of the high-temperature-resistant ceramics.

Usage area: Heating of the sample (0 – 1100 ºC).

Keywords: Heating of the sample.

Description: Analytical electronic balance, "Ohaus Analytical Plus"

Technical specification: Maximum sample weight - 110 g. Scaling value - 0.1mg.

Usage area: Sample mass measurements (0 - 110g, d = 0.0001g).

Keywords: Analytical balance

Description: Zeta Potential and Submicron Particle Size Analyzer Beckman Coulter DelsaNano C

Technical specification: Concentration: 10 ppm - 40%; particle size: 0.6 nm - 7 µm, 0.6 nm - 30 µm (zeta potential); Zeta potential: -200 mV - 200 mV.

Usage area: Particle sizing, zeta potential

Keywords: Particle sizing, zeta potential

Description: Centrifuge Hettich Universal 320 R

Technical specification: Speed 0-9000 rpm, temp.range -20- 40 ºC.

Usage area: For phase separation by centrifugation

Keywords: Centrifugation, phase separation

Description: ELPI ™ (Electrical Low Pressure Impactor). Enables measurement of real-time particle size distribution and concentration in the size range of 6nm - 10μm with 10Hz sampling rate

Technical specification: Particle size range - 0.006-10μm. Faction - 14. The sampling flow rate - 10 l/min.

Usage area: Real-time aerosol particle dispersion composition analysis, with the ability to collect particles of different fractions for further analysis (14 fractions, 0.006 - 10.0μm).

Keywords: Aerosol particles, dispersion composition.

Description: Nanoscan SMPS nanoparticle sizer 3910. Nanoparticle number concentration meter

Technical specification: Operating modes: scanning - particle distribution across the measurement range (60 s); The desired particle size monitoring (1s). Measuring range - 10 to 420nm. Particle concentration - 100 to 1,000,000 particles/cm3.

Usage area: Aerosol nanoparticle dispersion composition in real-time (10-420 nm).

Keywords: Aerosol nanoparticles

Description: PersonalDataRAM - pDR-1000AN. Measures concentrations of dust, smoke, mists and fumes in real-time

Technical specification: Aerosol concentration measurement range - 0.001 to 400.0mg/m3. Particle size range for maximum accuracy - 0.1 to 10μm.

Usage area: Measurements of personal exposure to aerosol particles in the workplace.

Keywords: Aerosol particles

Technical specification: Analysis temperature 40-300 oC

Usage area: Analysis of liquid and gas mixtures

Keywords: Gas chromatography, capilary column, flame ionisation detector, ion plasma detector

Description: FT-IR spectrometry system

Technical specification: System consists of Vertex70 spectrometer (Bruker), UV light source Omnicure S2000, Golden Gate Mk II ATR Accessory with Heated Diamond Top-plate, horizontal QuickLock transmittance accessory, standard spectral range covers 8,000 to 350cm-1, DTGS and MCT liquid nitrogen cooled detectors, rapid scan option for more than 68 spectra/sec at a spectral resolution of 16cm-1. Peaction monitoring option.

Usage area: Investigation of photopolymerisation and thermalpolymerisation, investigation of photodegradation processes in organic materials, investigation of organic materials during apllication of heat.

Keywords: Infrared absorbtion spectra, photopolymerisation, thermal polymerisation, photostability

Description: Hydrothermal processing of materials under high pressure system

Technical specification: Multiple controlled system by PC which consists of stirred and non-stirred autoclaves. Flexible process control unit to handle up to six individual autoclaves with PID temperature control and data logging for all relevant process data (pressure, temperature, time, rate of rotation and etc.). Exchangeable cylinders of pressure vessels in stirred and non-stirred autoclaves with different volumes. No welded parts (valves, adapters, cylinder and etc.) in the autoclaves, all parts screwed in, removable and exchangeable.

Usage area: Hydrothermal synthesis

Keywords: Stirred and non-stirred autoclaves

Description: Thermogravimetric Analyzer Linseis STA PT1600 coupled with mass spectrometer GSD320 Linseis/Pheiffer Vacuum

Technical specification: STA PT1600 specifications: temperature interval - -40 - 1500 °C; accuracy - ± 1 %; max. sample weight up to 5 g. Quadrupole mass spectrometer intervals - 1-100 amu; 1-200 amu; 1-300 amu.The synhronization of experiment beginning by STA-MS as well as the corelation during the whole experiment is guaranteed and controlled.

Usage area: The evaluation of physical and chemical properties of the sample (mass changes, decomposition, crystallization or melting temperature, specific heat and other thermal conversions) while the substance is subjected to a controlled temperature program in a specified atmosphere; the evaluation of evaporated gas from a sample.

Keywords: Simultaneous thermal analysis, evaporated gas analysis

Description: Beer making (brewing) unit

Technical specification: Two-vessel brewhouse with whirlpool; Two cylindroconical fermenting tanks and one open fermenter; It is possible to produce very small quantity of beverage (only 30 liters, in some cases even less). Laboratory equipment allows you to work using methods similar to specific large industry methods. Technological processes are automated, easily operated and programmed.

Usage area: For studies, research work in the field of brewing technology (fermentation), for technological investigations or development of new fermentable beverages.

Keywords: Beer making technology

Description: Equipment for composition and emulsions formation

Technical specification: Kilia vacuum bowl cutter 30L VK 4000 express. Advantage of the deep bowl form is the low minimum capacity of 20 %, which is important for recipes with a small production volume The maximum batch size depends on each product, but should usually not be over 80%. Knife shaft drive frequency converter controlled (AC-drive) with 6 fixed programmed speeds, 4 forward (50, 100, 2500, 5000 rpm), 2 reverse (50, 100 rpm). Variable bowl drive (7-20 rpm). Homogenizer-coloidal mill SG-1325-2B. Capacity 100 kg/h, 15 l. Meat mixer Fama Fic 30M. Capacity 30 kg. 47 rpm.

Usage area: Meat and fish technology

Keywords: Meat and fish technology

Description: cooling stand TE6/EV and TE6A/EV

Technical specification: Cooling water 0-100 l/h, heat element 60 W

Usage area: heat transfer service unit, linear heat conduction

Keywords: cooling

Description: Pressure losses pilot plant DPA/EV

Technical specification: Centriugal pump 0-10 m3/h. Manometer sygnal 4-20 mA

Usage area: Investigation of different fluid flow hydrodynamic structure

Keywords: fluid hydrodynamics

Description: Mettler Toledo T70 potentiometer.

Technical specification: pH measurement (0-14) selective measurement of ions Cu2 ; Cd2 ; Ca2 ; F-; Cl-

Usage area: titration,measurement of different ions concetration

Keywords: titration,measurement of ions concetration

Description: "Dekati ®"double diluter setup for combustion measurements

Technical specification: The dilution ratio - 1:49. Dilution air pressure - 2 bar. Operating temperature - 0-450 º C.

Usage area: The dilution device for sampling from concentrated sources.

Keywords: Diluter

Description: HPLC system with UV/VIS and DAD

Technical specification: Mamual injection, RIT detector, 5 independent channels with up to four solvents in a single run, the gradient can be made under high and low pressure.

Usage area: Chromatographic analysis

Keywords: Chromatography

Description: Liophylisator SPI Industries Sentry 2.0

Technical specification: Temp.range -50 - 10 ºC, vacuum range: 20-2000 mTorr.

Usage area: Freez-drying of materials

Keywords: Freez-drying

Description: Thermogravimeter

Technical specification: TA Instruments Q50. Max sample weight 1g, Temperature range - ambient to 1000oC, heating rate 0.1- 100oC/min

Usage area: Investigation of thermostability of organic materials

Keywords: Thermogravimetry

Description: HPLC system

Technical specification: Automatic injection, diode fluorescecnce detector, 2 independent channels with up to four solvents in a single run, column temperature control up to 40°C.

Usage area: Chromatographic analysis

Keywords: Chromatography

Description: DRON-6 powder X-ray diffractometer

Technical specification: powderX-ray diffractometer with Bragg-Brentano geometry using Ni-filtered CuKα radiation, operating at a voltage of 30 kV and an emission current of 24 mA. The step-scan covered the angular range 5–60 (2θ) in steps of 2θ = 0.02.

Usage area: powder X-ray analysis

Keywords: X-ray analysis

Description: Microwave reactor Anton Paar GmbH - Monowave 300

Technical specification: 850W. Max. Temp. 300°C, operating pressure 30 bar, max. pressure 200 bar. max. mixing speed 1200 rpm. Three SiC vessels, filling volume from 0.5 to 20 ml.

Usage area: Microvawe synthesis

Keywords: Microvawe synthesis

Description: Thermomechanical analyzator and dielectric spectrometer

Technical specification: MCR302 rheometer (Anton Paar). Heating range of convection oven is from -150 to 450oC. Plate-Plate geometries of 8 and 15mm available. Universal Extensional Fixture for soft films tension experiments. Dielectro-reological device, UV curing system.

Usage area: Rheological tests in rotational and oscillatory modes are possible. DMTA analysis of soft films, fibers, polymer melts. UV curing experiments. Detection of phase transitions by dielectric spectroscopy.

Keywords: dynamic mechanical thermal analysis, dielctric spectroscopy, UV curing

Description: Electroacustic spectrometer DT-300

Technical specification: Sample volume 2-100 ml, concentration 0.1-50%; particle size <100 micrometers

Usage area: For determination of zeta potential of particles in dispersions

Keywords: Zeta potential, electroacustic method

Description: Differential scanning calorimeter Perkin Elmer DSC8500

Technical specification: Temp.range -100 - +750 ºC, heating rate 0.1-750 ºC/min.

Usage area: For DSC measurements, for investigations of materials phase and physical transitions

Keywords: Differential scanning calorimetry

Description: Gelchromatografas Malvern Viscotek 270 Dual Detector

Technical specification: Refractive index and light scattering detectors, solvent DMSO, molecular weight range: 10000-4000000.

Usage area: For determination of molecular weight and polidispersity of biopolymers

Keywords: Gelchromatography, molecular weight

Description: Twin screw extruder KrausMaffei Berstorf GmbH ZE25Rx40D-UTXmi

Technical specification: Motor power: 26 kW; Throughput rate: 10kg/h; Speed screw (max): 1200 rpm; Number og heatable barrel housing: 7.

Usage area: Reactive extrusion of biopolymers

Keywords: Reactive extrusion

Description: Polymer characterization system - molecular sieve chromatograh

Technical specification: Elution - 0,05-2 ml/min, molecular mass interval - 100-4×106 D, detection ( UV detector 200-400 nm, RI detector,low and high angle light scattering detector), eluent degassing system, UV spectra registration

Usage area: determination of polymers molecular masses (Mn, Mw, Mz and polidispersity

Keywords: Molecular sieve chromatograhy, MSC, gel permeation chromatography, GPC, molecular mass

Description: Meat and fish thermal processing and cooling equipment

Technical specification: Universal Cooking and Smoking Installations BASTRAMAT, with Cooking, Roasting, Cooling, Drying, Climate maturing. Wood-chip smoke generation. Temperature range adjustable between +10° C and +100° C. Freezer Foinox BC 50 - 2A . All solid stainless steel construction . Operating temperature -+70° -18°, Pan capacity 5xGN1/1 - 5x(600x400). Output at +70°C +3°C-10,5 Kg. Output at +70°C -18°C-4,8Kg. Dimensions -750x700x850mmh

Usage area: Meat and fish thermal processing and cooling

Keywords: Meat and fish technology

Description: Thermal eveporation system integrated into the glove-box

Technical specification: Mbraun glove-box, gas purification system, gas purification system for closed cycle cirulation, Rotary vane pump and turmolecular pumps, Sensor-Set: H2O-analyzer and O2-analyzer, 2 x thermal evaporators for metals, 2 x evaporators for organics (temperature range: 50°C up to 600°C, typical deposition rates: (10-3)… 5 nm/sec)

Usage area: Organic electronics device formation

Keywords: Thermal evaporation, organic semiconductor, OLED, organic electronics

Description: Diferential scanning calorimeter

Technical specification: TA Instruments Q2000, temp range -90oC to 550oC, sensitivity 0.2mW, modulated DSC mode, direct Cp measurement, PhotoDSC option

Usage area: Investigation of phase transitions of organic materials, investigation of kinetics of chemical reactions, investigation of photopolymerisation

Keywords: diferential scanning calorimetry

Description: X-ray fluorescence spectrometer TIGER S 8

Technical specification: quantitative measurements of elements from beryllium to uraniumin in solids and liquids.

Usage area: Qualitative, quantitative and non-standard measurements of elements

Keywords: XRF

Description: Three stage cascade impactor "Dekati® PM10" for determining gravimetric mass size distribution of particles

Technical specification: Sample flow rate - 10 to 30 l/min. Three impactor stages for particles >10µm, 2.5µm and <1 µm.

Usage area: Aerosol particle dispersion composition analysis (0 - 1μm, 1 - 2.5μm, 2.5 - 10.0μm)

Keywords: Aerosol particles, dispersion composition.

Description: Luminescence spectrometer FLS980 (Edinburgh instruments)

Technical specification: Steady state mode, time resolved mode, nanosecond flash lamp, microsecon flash lamp, dewar flask,

Usage area: Fluorescence, phosphorescence, quantum yield , lifetime measurements of solid samples and solutions

Keywords: Fluorescence, phosphorescence, lifetime, quantum yield

Description: Mass detector and liquid chromatography system

Technical specification: System consists of mass detector and HPLC system. Mass detector is single quadrupole, the mass range 0-3000m/z, ESI, APCI positive/negative ionization modes. The sample could be separated by high perfomance liquid chromatography using reverse phase column (BEH C18). Eliuent could be mixed using four solvents.

Usage area: Molecular weight detection of organic materials, purity estimation of the organic materials

Keywords: Molecular weight, chromatography, purity

Description: Fermenters

Technical specification: fermenters with working volume 35-500 ml and 300-1200 ml, infrared radiation is used to warm the culture; does not require cooling water. used to warm the culture;

Usage area: Fermentation and cultivation with bacteria, yeasts or fungi.

Keywords: Laboratory fermenters, microbiological culture, fermentation

Description: Chromatography System

Technical specification: Single Quadrupole, ionisation mode ESI and/or APCI, 15,000 u/sec fast scanning speed, ultra-fast analysis and separation

Usage area: Separation of organic compounds, mass detection

Keywords: chromatography, analytical, preparative, mass spectroscopy

Description: Hydrothermal processing of materials under high pressure system

Technical specification: Max. temperature 350 oC Max.pressure 115 Bar.

Usage area: synthesi of materials under high pressure

Keywords: autoclave

Description: Dilatometer L75H1600C

Technical specification: Temperature interval - from room temperature to 1600 °C; max. sample size - 50 mm; sample diameter - 7/12/20 mm; measuring range: lowest limit - 100 mm, upper limit - 5000 mm.

Usage area: The evaluation of changes in the sample dimensions (volume) while the substance is subjected to a controlled temperature program in a specified atmosphere. Typical materials under investigation are: composite materials, glass, polymers, ceramics, metals. Besides, powder can also be analysed.

Keywords: Dilatometry

Description: 400 MHz NMR apparatus

Technical specification: 9.4 Tesla permanent magnetic field . Room temperature homogeneity outdoor activities ( shim ) system for optimal magnetic field homogeneity needed for 1D , 2D and 3D experiments without rotation of the sample cuvette , and not less than 20 orthogonal gradient control. Not less than 2 equivalent and interchangeable frequency channels of communication with the full wide -frequency generation in each , and the minimum interval for each channel 6-430 MHz Complete digital phase and amplitude of the best generation of long-term stability to achieve Digital real- time compensation The required frequency change: steps < 0.01 Hz Phase change: steps < 0.01 Grad, with no more than 25 ns duration Radio frequency system output signal phase singalong / accuracy by changing the power attenuation ( monotony ): not more than / - 0.5 and 90 dB power conversion range. Individual and / or along the phase , frequency and / or amplitude of the event time : no more than 25 ns Impulse control temporal resolution of 12.5 ns or less Software -controlled variable temperature unit , the temperature change of 0.1 ° C increments  . Temperature changes at the interval narrower than the range - 150 to 180 ° . a) 5 mm head with actively shielded Z - gradient, can apply monitoring / irradiation of the NMR core range from 15N to 31P ( below) as well as 1H and 19F . Automatic selection, setting and atitaikymas all clusters interval from 15N to 31P . The ability to record the 1H and 19F spin interactions termination and vice versa . The minimum required parameters : Signal / Noise: 19F sensitivity ≥ 350:1 (TFT sample , the 1H interactions termination ) 31P sensitivity ≥ 150:1 ( TPP sample) 13C sensitivity ≥ 190:1 (ASTM test) 15N sensitivity ≥ 25:1 (90 % formamide sample) 1H sensitivity ≥ 450:1 (0.1 % EC sample , 200 Hz) Temperature changes at the interval narrower than from - 150oC to 150 oC . b ) CP / MAS head 15N - 31P , 1H ; Rotor size 4 mm, rotation frequency up to 15 kHz; shall be accompanied by a pneumatic module for precise spin speed , transfer MAS rotor system . The head must be compatible with automatic sample changer. Temperature changes at the interval narrower than the range of -50 ° C to 80 ° C .

Usage area: For NMR investigations in solutions at variable temperature. 1H NMR, 13C NMR, 31P NMR, DEPT, INEPT, COSY, TOCSY, NOE, 13C HSQC, 13C HMBC.

Keywords: Nuclear magnetic resonance NMR, COSY, DEPT, HMBC, HSQC, NOE

Description: 700 MHz NMR spectrometer

Technical specification: 9.4 Tesla permanent magnetic field . Room temperature homogeneity outdoor activities ( shim ) system for optimal magnetic field homogeneity needed for 1D , 2D and 3D experiments without rotation of the sample cuvette , and not less than 20 orthogonal gradient control. Not less than 2 equivalent and interchangeable frequency channels of communication with the full wide -frequency generation in each , and the minimum interval for each channel 6-430 MHz Complete digital phase and amplitude of the best generation of long-term stability to achieve Digital real- time compensation The required frequency change: steps < 0.01 Hz Phase change: steps < 0.01 Grad, with no more than 25 ns duration Radio frequency system output signal phase singalong / accuracy by changing the power attenuation ( monotony ): not more than / - 0.5 and 90 dB power conversion range. Individual and / or along the phase , frequency and / or amplitude of the event time : no more than 25 ns Impulse control temporal resolution of 12.5 ns or less Software -controlled variable temperature unit , the temperature change of 0.1 ° C increments  . Temperature changes in the range - 150 to 180 ° . a) 5 mm head with actively shielded Z - gradient, can apply monitoring / irradiation of the NMR core range from 15N to 31P ( below) as well as 1H and 19F . Automatic selection, setting and atitaikymas all clusters interval from 15N to 31P . The ability to record the 1H and 19F spin interactions termination and vice versa . The minimum required parameters : Signal / Noise: 19F sensitivity ≥ 350:1 (TFT sample , the 1H interactions termination ) 31P sensitivity ≥ 150:1 ( TPP sample) 13C sensitivity ≥ 190:1 (ASTM test) 15N sensitivity ≥ 25:1 (90 % formamide sample) 1H sensitivity ≥ 450:1 (0.1 % EC sample , 200 Hz) Temperature changes at the interval narrower than from - 150oC to 150 oC . b ) CP / MAS head 15N - 31P , 1H ; Rotor size 4 mm, rotation frequency up to 15 kHz; shall be accompanied by a pneumatic module for precise spin speed , transfer MAS rotor system . The head must be compatible with automatic sample changer. Temperature changes in the range of -50 ° C to 80 ° C .

Usage area: for recording NMR spectra from solutions in various temperatures. 1H NMR, 13C NMR, 31P NMR, DEPT, INEPT, COSY, TOCSY, NOE, 13C HSQC, 13C HMBC.

Keywords: Nuclear magnetic resonance NMR, COSY, DEPT, HMBC, HSQC, NOE

Description: System SPECTRUM GX 2000 RAMAN Nr.68891, HATR ACCESSORY FOR SPECTRUM GX

Technical specification: Diapazone of FTIR spectrum 10 000-200 cm-1, HATR FTIR spectrum diapazone 4000-460 cm-1 ribose

Usage area: FTIR analysis of anorganic, organic ang polymer materials

Keywords: FTIR, HATR

Description:

The triple quadrupole mass spectrometer allows for increased sensitivity and specificity yielding lower detection and quantitation limits. TQ-MS can be employed in the fields of drug metabolism, pharmacokinetics, environmental studies, food and biological analyses. In environmental and biological studies, the triple quadrupole is useful for quantitative studies that involved identifying whether or not specific substances are present in a sample.

Ultra performance liquid chromatography allows separation of the mixtures of compounds of high to medium polarity and supercritical fluid chromatography separates compounds of low polarity.

Usage area: Determination of concentrations of individual compounds in complex compound mixtures.

Keywords: chromatography, mass spectrometry, separation, quantitation

Results of services (167)

Keywords: microbiological analysis, model food systems

Keywords: Instrumental methods (texture, viscosity and stability )

Description: null

Keywords: f

Description: Food products, in addition to the basic functions - supplying the body with the necessary nutrients and energinėmis materials can enhance the human body, to act preventively to reduce disease risks. These are functional foods (FM) products. Recently, many countries have formed summarizes FM products conception: it is - consumer daily intake of food, which, in addition to nutritional value, they added a physiological effect on the human body (Richardson, 2002; Fernandes-Gines et al., 2005). FM products - a rapidly developing food industries. In many countries, the volume is increasing. Major manufacturers - Japan, the United States, Canada, Australia, Austria, Belgium, Denmark, Finland, France, Germany, the Netherlands, Sweden, Switzerland, Norway and the United Kingdom. US produced the majority of FM products. FM products - one of the most promising areas of the food industry. Service: *A detailed overview of literature and experimental design creation; *Fractionation of vegetable raw materials conventional extraction methods; *Fractionation of plant raw materials of high pressure extraction methods; *In obtained extracts antioxidant potential rating; *The original of the extract obtained phytochemical composition assessment; *Analysis of the results, conclusions and recommendations Submission; * With respect to the raw material or extract features. Duration of the services is about 15 weeks.

Keywords: Technological investigations of making of beer and similar beverages

Keywords: Technological investigations of mashing and wort production for making beer and similar beverages

Keywords: Meat, technology, quality, energy value

Keywords: Catering products, nutrition value, chemical composition

Keywords: catering products, quality, component changes, technology

Keywords: antimicrobial bioproducts, elimination of biological contamination, food and beverages, increasing of functionality and safety, biodetergents

Keywords: cereal, quality evaluation

Description: null

Keywords: enzyme activity, reaction kinetics

Description: null

Keywords: bread, confectionery products, novel technologies, recommendations

Description: null

Keywords: Enzyme compositions, plant products, improvement of quality, increasing the efficiency

Description: null

Keywords: Bioethanol, plant biomass, technologies

Description: null

Keywords: Biopolymers, nanomaterials, packaging

Description: null

Keywords: Industrial effluants, purification technologies

Description: null

Keywords: Biopolymers, chemical, physical and mechanical modification

Description: null

Keywords: Biopolymers, chemical, physical and mechanical modification

Description: null

Keywords: Biopolymers, bioactive properties

Description: null

Keywords: Measurement, fluorescence, phosphorescence

Description: null

Keywords: Adsorbents, chromatography

Description: Creation of innovative cosmetics prescriptions Description: The basic cosmetic prescription. Consultation bioactive additives (vitamins, minerals, flavonoids, hydroxy acids, UV filters) application in cosmetics issues. Raw materials and additives advantages and disadvantages of additive benefit. Detailed description: - Review of the literature* and formation of experimental schemes. - One type of cosmetics formulator of preparation, indicating the percentage of ingredients. - Stability studies of developed product. - Analysis of the results, conclusions and recommendations. * Taking into account the customer's preferred raw material. Duration ~ 12 months.

Keywords: Cosmetic preparation

Description: null

Keywords: Molecular weight determination of polymers by SEC, GPC

Description: null

Keywords: Organic synthesis, electroactive materials

Description: null

Keywords: Polymers, composites, renewable resources

Description: null

Keywords: Hide/skin preservation, beamhouse processes

Description: null

Keywords: polymerisation, curing , kinetics, photoinitiators

Description: null

Keywords: organic light emitting diodes

Keywords: new innovative product, building materials industry, glass industry

Description: null

Keywords: Municipal waste, industrial waste, composition of waste

Description: null

Keywords: Municipal waste, industrial waste, composition of waste

Description: null

Keywords: Municipal waste, prognostic models

Description: null

Keywords: Municiipal waste, landfills, recyclable materials

Description: null

Keywords: Municipal waste, management plans

Description: null

Keywords: Waste decontamination, environmental impact assessment

Description: null

Keywords: Environmental impact assessment, integrated pollution prevention and control

Description: Possible services: * water quality setting; * pilot installation design and production; * pilot installation of wiring and adjustment works; * analyte (works carried out in the customer's company); * the study of optimal operating mode selection processes and system performance tests. The duration of services: at least 8 months (depending on the customer's activities).

Keywords: Municipal wastewater, special wastewater, treatment technologies

Description: Water is essential for life - it is an indispensable component of nutrition, because the vital processes can take place only if there is enough water in the cells. Water accounts for the largest part of the human body - about 60-70 percent. Nothing humans do not perform so much more variety of functions like water: it is necessary physiological digestion and elimination processes, supports cellular fluid physical and chemical stability, maintain body temperature invariable. The water shortage is very sensitive to the brain, which contains 85 per cent. of water. Since the brain is only 2 percent. Human body weight, except water and oxygen consumption by 20 per cent. Total body's needs. It is important to get the required daily amount of water, so a healthy person the recommended daily oral administration of approximately 8 glasses of water. Detailed description of the service: - Detailed water quality studies and experiments schemes * Conclusion - Pilot installation design and production - Pilot installation of installation and adjustment works - Analyte * - Study the optimal working mode selection processes and system performance tests * Work carried out in the customer company. Duration of service - about 10 months.

Keywords: Drinking water, water quality, improvement technologies

Description: null

Keywords: Membrane water purification, oxydation water purification, plasma

Description: null

Keywords: Water treatment, technologies, feasibility studies

Description: null

Keywords: Ambient air, indoor air, air quality, air pollution, microclimate

Description: null

Keywords: Energy, fuel combustion, pollution, particle size distribution

Description: null

Keywords: Air pollutants, industtrial processes, pollutant measurements, pollution abatement

Description: null

Keywords: Air filters, filtration materials

Description: null

Keywords: Air filters, filtration materials, nanofibres

Description: null

Keywords: Air pollution, pollutant decomposition, advanced oxidation, plasma

Description: null

Keywords: Indoor air quality, air cleaning units

Description: null

Keywords: water pollution, air pollution, microbiological pollution

Description: null

Keywords: Life cycle assessment, environmental impact assessment

Description: null

Keywords: Fertilizer, composition, strength of granules, fraction

Description: null

Keywords: Fertilizer, strength of granules, fraction

Description: null

Keywords: Fertilizer, composition, stability, pH, viscosity, density

Keywords: Kinetic and equilibrium parameters, emissions, equipment, engineering calculations

Description: null

Keywords: Fertilizers, technology, regulative documents

Description: null

Keywords: Nickel and silver deposition, anodation

Keywords: Separator

Keywords: Fermented products production vessel

Keywords: Cheese production

Keywords: Acoustic method; porous food systems, analysis

Keywords: Food products, sensory analysis, acceptability testing, FaceReader programme

Keywords: Selection, enzymes, plant material processing

Keywords: Microorganisms, cultivation conditions, selection

Keywords: Cereals, quality parameters, determination, evaluation

Keywords: Enzyme activity, determination, spectrophotometric method

Keywords: Proteins, quantitative analysis, ion-exchange chromatography

Keywords: Proteins, molecular mass, isoelectric point, electrophoresis, determination

Keywords: Lactic acid, L/D isomers, total content, determination

Keywords: Baked goods, cereal products, quality parameters, determination, evaluation

Keywords: Bread, flour confectionary, baking test

Keywords: Baked goods, cereal products, formula development

Keywords: Freez-drying

Keywords: Flash chromatography, purification, organic materials, preparative scale

Keywords: Molecular sieve chromatograhy, MSC, gel permeation chromatography, GPC, molecular mass

Description: null

Keywords: Phosphorescence, fluorescence, emission lifetime, quantum yield, solutions, solid samples

Description: null

Keywords: molecular orbital energy

Description: null

Keywords: X-ray analysis, single crystal

Keywords: organic light emitting diode, vacuum evaporation

Keywords: glass transition, melting, crystallisation, destruction, morphological stability

Keywords: polymerisation, curing , kinetics, photoinitiators, FTIR-ATR

Keywords: oxidation, reduction potentials, cyclic voltammetry

Keywords: molecular mass, chemical ionisation, mass spectrometry

Keywords: microcalorimetric analysis

Description: .

Keywords: .

Description: .

Keywords: .

Keywords: Drinking water, microbiological safety

Keywords: Smart and intelligent packaging, packaging materials

Keywords: Bioactive properties, packaging materials

Description: Enzymes have an important role in leather manufacture and the use of biocatalysts is now considered to be state-of-the-art for the processing of animals skins and hides. The main objective of the research is to assess applicability of new enzymes in conformity with an effect on hide/skin properties change.

Keywords: enzyme, hide/skin, leather processing.

Description: Processing of leather is related with significant pollution of environment by solid and liquid wastes. The work is devoted for an establishment of possibilities of utilization or recycle of wastes of leather industry. The properties of products obtained from the wastes would be established as well.

Keywords: hide/skin, wastes, utilization.

Description: Aim of investigation is a development of processes of leather manufacture, applying new materials and readjusting equipment.

Keywords: leather, fur, new technologies.

Description: Change of an assortment of processed leather leads to the necessity of assessment of current technologies. Work is devoted for the estimation of the suitability of current processes according to the qualitative indexes of the leather.

Keywords: leather, fur, determination of properties.

Description: Development of a teaching model, as a functional tool of a tannery for the human resources processes management (e.g.: training, performance management) which helps to sustain the consistency of the company's work processes by implementing innovative technologies.

Keywords: leather tanning, innovation, teaching.

Description: Biogas production from the by-products of spirits industry (spent distiller’s grains)

Keywords: Biogas production, spent distiller’s grains

Description: Determination of optimal conditions of polymer synthesis. Chemical modification of polymers. The choosing of additives in order to obtain optimal properties of the product. Thermal analysis and spectroscopy of polymers.

Keywords: Polymers, modification, synthesis, Thermal analysis, spectroscopy